Effect of a functional monomer (MDP) on the enamel bond durability of single-step self-etch adhesives

2015 ◽  
Vol 124 (1) ◽  
pp. 96-102 ◽  
Author(s):  
Kenji Tsuchiya ◽  
Toshiki Takamizawa ◽  
Wayne W. Barkmeier ◽  
Keishi Tsubota ◽  
Akimasa Tsujimoto ◽  
...  
2013 ◽  
Vol 38 (1) ◽  
pp. 48-56 ◽  
Author(s):  
HA El-Deeb ◽  
HH Al Sherbiney ◽  
EH Mobarak

SUMMARY Objective: To evaluate the dentin bond strength durability of adhesives containing modified-monomer with/without-fluoride after storage in artificial saliva and under intrapulpal pressure simulation (IPPS). Materials and Methods: The occlusal enamel of 48 freshly extracted teeth was trimmed to expose midcoronal dentin. Roots were sectioned to expose the pulp chamber and to connect the specimens to the pulpal-pressure assembly. Specimens were assigned into four groups (n=12) according to adhesive system utilized: a two-step etch-and-rinse adhesive system (SB, Adper Single Bond 2, 3M ESPE), a two-step self-etch adhesive system (CSE, Clearfil SE Bond, Kuraray Medical Inc), and two single-step self-etch adhesives with the same modified monomer (bis-acrylamide)—one with fluoride (AOF, AdheSE One F, Ivoclar-Vivadent) and the other without (AO, AdheSE One, Ivoclar-Vivadent). Bonding was carried out while the specimens were subjected to 15-mm Hg IPPS. Resin composite (Valux Plus, 3M ESPE) buildups were made. After curing, specimens were aged in artificial saliva and under 20-mm Hg IPPS at 37°C in a specially constructed incubator either for 24 hours or six months prior to testing. Bonded specimens (n=6/group) were sectioned into sticks (n=24/group) with a cross section of 0.9 ± 0.01 mm2 and subjected to microtensile bond strength (μTBS) testing using a universal testing machine. Data were statistically analyzed using two-way analysis of variance (ANOVA) with repeated measures, one-way ANOVA tests, and a t-test (p<0.05). Failure modes were determined using a scanning electron microscope. Results: The μTBS values of SB and CSE fell significantly after six-month storage in artificial saliva and under IPPS, yet these values remained significantly higher than those for the other two adhesives with modified monomers. There was no significant difference in the bond strength values between fluoride-containing and fluoride-free self-etch adhesive systems (AOF and AO) after 24 hours or six months. Modes of failure were mainly adhesive and mixed. Conclusions: Based on the results of this study, 1) Fluoride addition did not affect dentin bond durability; and 2) despite the fact that the single-step adhesive system with modified monomer showed stability, bond strengths associated with these systems remained lower than those of multistep adhesive systems.


2015 ◽  
Vol 34 (5) ◽  
pp. 611-617 ◽  
Author(s):  
Kie NOJIRI ◽  
Akimasa TSUJIMOTO ◽  
Takayuki SUZUKI ◽  
Syo SHIBASAKI ◽  
Saki MATSUYOSHI ◽  
...  

2002 ◽  
Vol 81 (7) ◽  
pp. 472-476 ◽  
Author(s):  
F.R. Tay ◽  
D.H. Pashley ◽  
M. Yoshiyama

Self-etch adhesives that etch, prime, and bond simultaneously should not exhibit incomplete resin infiltration within hybrid layers. We hypothesized that nanoleakage patterns in these systems are artifacts caused by mineral dissolution in mildly acidic silver nitrate. Resin-dentin interfaces bonded with four single-step, self-etch adhesives were examined for nanoleakage by conventional (pH 4.2) and basic ammoniacal (pH 9.5) silver nitrate and prepared for transmission electron microscopy. All adhesives exhibited a reticular mode of nanoleakage within hybrid layers when conventional silver nitrate was used. With ammoniacal silver nitrate, an additional spotted pattern of nanoleakage was observed within adhesive and hybrid layers. The reticular mode of nanoleakage in self-etch adhesives probably represents sites of incomplete water removal that leads to regional suboptimal polymerization. The spotted pattern identified with the use of ammoniacal silver nitrate probably represents potentially permeable regions in the adhesive and hybrid layers that result from the interaction of the basic diamine silver ions with acidic/hydrophilic resin components.


2006 ◽  
Vol 48 (2) ◽  
pp. 63-69 ◽  
Author(s):  
Yohei Asaka ◽  
Kanako Yamaguchi ◽  
Hirohiko Inage ◽  
Toshiki Takamizawa ◽  
Hiroyasu Kurokawa ◽  
...  

2009 ◽  
Vol 34 (6) ◽  
pp. 716-724 ◽  
Author(s):  
S. Wei ◽  
Y. Shimada ◽  
A. Sadr ◽  
J. Tagami

Clinical Relevance Double-application enhanced the hardness of bonding layer and resin-dentin interface for all the adhesives used; however, it only improved the bond strength to dentin for some of the single-step self-etch adhesives.


10.2341/08-26 ◽  
2008 ◽  
Vol 33 (6) ◽  
pp. 702-709 ◽  
Author(s):  
M. Ikeda ◽  
K. Tsubota ◽  
T. Takamizawa ◽  
T. Yoshida ◽  
M. Miyazaki ◽  
...  

Clinical Relevance To achieve optimum bond strengths, acid etching of dentin prior to the application of single-step self-etch adhesive systems should be avoided.


2015 ◽  
Vol 57 (2) ◽  
pp. 101-108 ◽  
Author(s):  
Hiroyasu Kurokawa ◽  
Toshiki Takamizawa ◽  
Akitomo Rikuta ◽  
Keishi Tsubota ◽  
Masashi Miyazaki

2010 ◽  
Vol 35 (1) ◽  
pp. 77-83 ◽  
Author(s):  
H. Tsuchiya ◽  
K. Tsubota ◽  
M. Iwasa ◽  
S. Ando ◽  
M. Miyazaki ◽  
...  

Clinical Relevance Proper application duration of single-step self-etch adhesive plays an important role in obtaining optimal enamel bond strength.


2017 ◽  
Vol 22 (3) ◽  
pp. 1113-1122 ◽  
Author(s):  
Soshi Suzuki ◽  
Toshiki Takamizawa ◽  
Arisa Imai ◽  
Akimasa Tsujimoto ◽  
Keiichi Sai ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document