Photoelastic stress analysis of different types of anterior teeth splints

2020 ◽  
Author(s):  
Murilo Baena Lopes ◽  
Klissia Romero Felizardo ◽  
Ricardo Danil Guiraldo ◽  
Karina Fancio Sella ◽  
Sérgio Ramos Junior ◽  
...  
2006 ◽  
Vol 25 (1) ◽  
pp. 145-150 ◽  
Author(s):  
Takashi NAKAMURA ◽  
Tatsuo OHYAMA ◽  
Tomonori WAKI ◽  
Soichiro KINUTA ◽  
Kazumichi WAKABAYASHI ◽  
...  

2014 ◽  
Vol 24 (1) ◽  
pp. 52-56 ◽  
Author(s):  
Bruno Salles Sotto-Maior ◽  
Plinio Mendes Senna ◽  
João Paulo da Silva-Neto ◽  
Mauro Antônio de Arruda Nóbilo ◽  
Altair Antoninha Del Bel Cury

2017 ◽  
Vol 117 (3) ◽  
pp. 373-379 ◽  
Author(s):  
Anna Gabriella Camacho Presotto ◽  
Cláudia Lopes Brilhante Bhering ◽  
Marcelo Ferraz Mesquita ◽  
Valentim Adelino Ricardo Barão

1980 ◽  
Vol 43 (6) ◽  
pp. 611-617 ◽  
Author(s):  
Harley H. Thayer ◽  
Angelo A. Caputo

1986 ◽  
Vol 29 (255) ◽  
pp. 2784-2788
Author(s):  
Tomoaki TSUJI ◽  
Toshikazu SHIBUYA ◽  
Takashi KOIZUMI

2021 ◽  
Vol 12 (2) ◽  
pp. 5-8
Author(s):  
Sachin Passi ◽  
Amit Bhagat ◽  
Preeti Choudhary ◽  
Aiyana Parthi ◽  
Sourabh Bhagat ◽  
...  

2012 ◽  
Vol 13 (6) ◽  
pp. 867-872 ◽  
Author(s):  
Sudhir Kumar ◽  
P Ratnakar ◽  
NV Murali Krishna Chakka ◽  
Sanjib Das ◽  
Anandamy Bagchi ◽  
...  

ABSTRACT Aims Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Materials and methods Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Statistical analysis Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Results Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Conclusion Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy. How to cite this article Chakka NVMK, Ratnakar P, Das S, Bagchi A, Kumar S, Anumula L. Do NiTi Instruments show Defects before Separation? Defects caused by Torsional Fatigue in Hand and Rotary Nickel-Titanium (NiTi) Instruments which Lead to Failure during Clinical Use. J Contemp Dent Pract 2012;13(6):867-872.


Strain ◽  
1993 ◽  
Vol 29 (2) ◽  
pp. 55-58
Author(s):  
C.D.J. Rushforth ◽  
D.R. Bearn ◽  
J.C. Aird

Sign in / Sign up

Export Citation Format

Share Document