Use of continuous glucose monitoring in patients with diabetes on peritoneal dialysis: poor correlation with HbA1cand high incidence of hypoglycaemia

2016 ◽  
Vol 33 (9) ◽  
pp. e17-e20 ◽  
Author(s):  
E. Oei ◽  
N. Samad ◽  
A. Visser ◽  
T. A. Chowdhury ◽  
S. L. Fan
2015 ◽  
Vol 41 (1-3) ◽  
pp. 18-24 ◽  
Author(s):  
Ahad Qayyum ◽  
Tahseen A. Chowdhury ◽  
Elizabeth Ley Oei ◽  
Stanley L. Fan

Introduction: Glycated hemoglobin is used to assess diabetic control although its accuracy in dialysis has been questioned. How does it compare to the Continuous Glucose Monitoring System (CGMS) in peritoneal dialysis (PD) patients? Methods: We conducted a retrospective analysis of 60 insulin-treated diabetic patients on PD. We determined the mean interstitial glucose concentration and the proportion of patients with hypoglycemia (<4 mmol/l) or hyperglycemia (>11 mmol/l). Results: The correlation between HbA1c and glucose was 0.48, p < 0.0001. Three of 15 patients with HbA1c >75 mmol/mol experienced significant hypoglycemia (14-144 min per day). The patients with frequent episodes of hypoglycemia could not be differentiated from those with frequent hyperglycemia by demographics or PD prescription. Conclusion: HbA1c and average glucose levels measured by the CGMS are only weakly correlated. On its own, HbA1c as an indicator of glycemic control in patients with diabetes on PD appears inadequate. We suggest that the CGMS technology should be more widely adopted.


Diabetes ◽  
2021 ◽  
Vol 70 (Supplement 1) ◽  
pp. 735-P
Author(s):  
CHAOFAN WANG ◽  
WEN XU ◽  
XUBIN YANG ◽  
JINHUA YAN ◽  
DAIZHI YANG ◽  
...  

2014 ◽  
Vol 46 (11) ◽  
pp. 810-813 ◽  
Author(s):  
F. Chantrel ◽  
H. Sissoko ◽  
L. Képénékian ◽  
A. Smagala ◽  
L. Meyer ◽  
...  

2021 ◽  
Author(s):  
Georgia M. Davis ◽  
Elias K. Spanakis ◽  
Alexandra L. Migdal ◽  
Lakshmi G. Singh ◽  
Bonnie Albury ◽  
...  

<b>Background: </b>Advances in continuous glucose monitoring (CGM) have transformed ambulatory diabetes management. Until recently, inpatient use of CGM has remained investigational with limited data on its accuracy in the hospital setting. <p><b>Methods: </b>To analyze the accuracy of Dexcom G6 CGM,<b> </b>we compared retrospective matched-pair CGM and capillary point-of-care (POC) glucose data from three inpatient CGM studies (two interventional and one observational) in general medicine and surgery patients with diabetes treated with insulin. Analysis of accuracy metrics included mean absolute relative difference (MARD), median absolute relative difference (ARD), and proportion of CGM values within ±15, 20 and 30% or ±15, 20 and 30 mg/dL of POC reference values for blood glucose >100 mg/dL or ≤100 mg/dL, respectively (?/15, /20, 0/30). Clinical reliability was assessed using Clarke error grid analyses.</p> <p><b>Results: </b>A total of 218 patients were included (96% with type 2 diabetes) with a mean age of 60.6 ± 12 years. The overall MARD (n=4,067 matched glucose pairs) was 12.8% and median ARD was 10.1% [IQR 4.6, 17.6]. The proportion of readings meeting ?/15, /20 and 0/30 criteria were 68.7, 81.7, and 93.8%. Clarke error grid analysis showed 98.7% of all values in zones A+B. MARD and median ARD were higher in hypoglycemia (<70mg/dL) and severe anemia (hemoglobin <7g/dL).</p> <p><b>Conclusion: </b>Our results indicate that CGM technology is a reliable tool for hospital use and may help improve glucose monitoring in non-critically ill hospitalized patients with diabetes. </p>


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Jen-Hung Huang ◽  
Yung-Kuo Lin ◽  
Ting-Wei Lee ◽  
Han-Wen Liu ◽  
Yu-Mei Chien ◽  
...  

Abstract Background Glucose monitoring is vital for glycemic control in patients with diabetes mellitus (DM). Continuous glucose monitoring (CGM) measures whole-day glucose levels. Hemoglobin A1c (HbA1c) is a vital outcome predictor in patients with DM. Methods This study investigated the relationship between HbA1c and CGM, which remained unclear hitherto. Data of patients with DM (n = 91) who received CGM and HbA1c testing (1–3 months before and after CGM) were retrospectively analyzed. Diurnal and nocturnal glucose, highest CGM data (10%, 25%, and 50%), mean amplitude of glycemic excursions (MAGE), percent coefficient of variation (%CV), and continuous overlapping net glycemic action were compared with HbA1c values before and after CGM. Results The CGM results were significantly correlated with HbA1c values measured 1 (r = 0.69) and 2 (r = 0.39) months after CGM and 1 month (r = 0.35) before CGM. However, glucose levels recorded in CGM did not correlate with the HbA1c values 3 months after and 2–3 months before CGM. MAGE and %CV were strongly correlated with HbA1c values 1 and 2 months after CGM, respectively. Diurnal blood glucose levels were significantly correlated with HbA1c values 1–2 months before and 1 month after CGM. The nocturnal blood glucose levels were significantly correlated with HbA1c values 1–3 months before and 1–2 months after CGM. Conclusions CGM can predict HbA1c values within 1 month after CGM in patients with DM.