Shuttle walking test in obese women: test-retest reliability and concurrent validity with peak oxygen uptake

2014 ◽  
Vol 35 (2) ◽  
pp. 120-126 ◽  
Author(s):  
Soraia P. Jürgensen ◽  
Renata Trimer ◽  
Victor Z. Dourado ◽  
Luciana Di Thommazo-Luporini ◽  
José C. Bonjorno-Junior ◽  
...  
2022 ◽  
Vol 15 (1) ◽  
Author(s):  
Peter Düking ◽  
Philipp Kunz ◽  
Florian A. Engel ◽  
Helena Mastek ◽  
Billy Sperlich

Abstract Objective Portable gas exchange instruments allow the assessment of peak oxygen uptake (V̇O2peak) but are often bulky, expensive and require wearing a face mask thereby limiting their routine application. A newly developed miniaturized headset (VitaScale, Nuremberg, Germany) may overcome these barriers and allow measuring V̇O2peak without applying a face mask. Here we aimed (i) to disclose the technical setup of a headset incorporating a gas and volume sensor to measure volume flow and expired oxygen concentration and (ii) to assess the concurrent criterion-validity of the headset to measure V̇O2peak in 44 individuals exercising on a stationary cycle ergometer in consideration of the test–retest reliability of the criterion measure. Results The coefficient of variation (CV%) while measuring V̇O2peak during incremental cycling with the headset was 6.8%. The CV% for reliability of the criterion measure was 4.0% for V̇O2peak. Based on the present data, the headset might offer a new technology for V̇O2peak measurement due to its low-cost and mask-free design.


PLoS ONE ◽  
2017 ◽  
Vol 12 (7) ◽  
pp. e0181008 ◽  
Author(s):  
Michael J. Hutchinson ◽  
Thomas A. W. Paulson ◽  
Roger Eston ◽  
Victoria L. Goosey-Tolfrey

2021 ◽  
Author(s):  
Pim van Oirschot ◽  
Marco Heerings ◽  
Karine Wendrich ◽  
Bram den Teuling ◽  
Frank Dorssers ◽  
...  

BACKGROUND Walking disturbances are a common dysfunction in persons with multiple sclerosis (MS). The 2-Minute Walking Test (2MWT) is widely used to quantify walking speed. We implemented a smartphone-based 2MWT (s2MWT) in MS sherpa, an app for persons with MS. When performing the s2MWT, users of the app are instructed to walk as fast as safely possible for 2 minutes in the open air, while the app records their movement and calculates the distance walked. OBJECTIVE The aim of this study is to investigate the concurrent validity and test-retest reliability of the MS sherpa s2MWT. METHODS We performed a validation study on 25 persons with relapsing-remitting MS and 79 healthy control (HC) participants. In the HC group, 21 participants were matched to the persons with MS based on age, gender, and education and these followed the same assessment schedule as the persons with MS (the <i>HC-matched</i> group), whereas 58 participants had a less intense assessment schedule to determine reference values (the <i>HC-normative</i> group). Intraclass correlation coefficients (ICCs) were determined between the distance measured by the s2MWT and the distance measured using distance markers on the pavement during these s2MWT assessments. ICCs were also determined for test-retest reliability and derived from 10 smartphone tests per study participant, with 3 days in between each test. We interviewed 7 study participants with MS regarding their experiences with the s2MWT. RESULTS In total, 755 s2MWTs were completed. The adherence rate for the persons with MS and the participants in the HC-matched group was 92.4% (425/460). The calculated distance walked on the s2MWT was, on average, 8.43 m or 5% (SD 18.9 m or 11%) higher than the distance measured using distance markers (n=43). An ICC of 0.817 was found for the concurrent validity of the s2MWT in the combined analysis of persons with MS and HC participants. Average ICCs of 9 test-retest reliability analyses of the s2MWT for persons with MS and the participants in the HC-matched group were 0.648 (SD 0.150) and 0.600 (SD 0.090), respectively, whereas the average ICC of 2 test-retest reliability analyses of the s2MWT for the participants in the HC-normative group was 0.700 (SD 0.029). The interviewed study participants found the s2MWT easy to perform, but they also expressed that the test results can be confronting and that a pressure to reach a certain distance can be experienced. CONCLUSIONS The high correlation between s2MWT distance and the conventional 2MWT distance indicates a good concurrent validity. Similarly, high correlations underpin a good test-retest reliability of the s2MWT. We conclude that the s2MWT can be used to measure the distance that the persons with MS walk in 2 minutes outdoors near their home, from which both clinical studies and clinical practice can benefit.


10.2196/29128 ◽  
2021 ◽  
Vol 5 (11) ◽  
pp. e29128
Author(s):  
Pim van Oirschot ◽  
Marco Heerings ◽  
Karine Wendrich ◽  
Bram den Teuling ◽  
Frank Dorssers ◽  
...  

Background Walking disturbances are a common dysfunction in persons with multiple sclerosis (MS). The 2-Minute Walking Test (2MWT) is widely used to quantify walking speed. We implemented a smartphone-based 2MWT (s2MWT) in MS sherpa, an app for persons with MS. When performing the s2MWT, users of the app are instructed to walk as fast as safely possible for 2 minutes in the open air, while the app records their movement and calculates the distance walked. Objective The aim of this study is to investigate the concurrent validity and test-retest reliability of the MS sherpa s2MWT. Methods We performed a validation study on 25 persons with relapsing-remitting MS and 79 healthy control (HC) participants. In the HC group, 21 participants were matched to the persons with MS based on age, gender, and education and these followed the same assessment schedule as the persons with MS (the HC-matched group), whereas 58 participants had a less intense assessment schedule to determine reference values (the HC-normative group). Intraclass correlation coefficients (ICCs) were determined between the distance measured by the s2MWT and the distance measured using distance markers on the pavement during these s2MWT assessments. ICCs were also determined for test-retest reliability and derived from 10 smartphone tests per study participant, with 3 days in between each test. We interviewed 7 study participants with MS regarding their experiences with the s2MWT. Results In total, 755 s2MWTs were completed. The adherence rate for the persons with MS and the participants in the HC-matched group was 92.4% (425/460). The calculated distance walked on the s2MWT was, on average, 8.43 m or 5% (SD 18.9 m or 11%) higher than the distance measured using distance markers (n=43). An ICC of 0.817 was found for the concurrent validity of the s2MWT in the combined analysis of persons with MS and HC participants. Average ICCs of 9 test-retest reliability analyses of the s2MWT for persons with MS and the participants in the HC-matched group were 0.648 (SD 0.150) and 0.600 (SD 0.090), respectively, whereas the average ICC of 2 test-retest reliability analyses of the s2MWT for the participants in the HC-normative group was 0.700 (SD 0.029). The interviewed study participants found the s2MWT easy to perform, but they also expressed that the test results can be confronting and that a pressure to reach a certain distance can be experienced. Conclusions The high correlation between s2MWT distance and the conventional 2MWT distance indicates a good concurrent validity. Similarly, high correlations underpin a good test-retest reliability of the s2MWT. We conclude that the s2MWT can be used to measure the distance that the persons with MS walk in 2 minutes outdoors near their home, from which both clinical studies and clinical practice can benefit.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Widjane Sheila Ferreira Goncalves ◽  
Rebecca Byrne ◽  
Pedro Israel Cabral de Lira ◽  
Marcelo Tavares Viana ◽  
Stewart G. Trost

Abstract Background Childhood obesity has increased remarkably in low and middle-income (LMIC) countries. Movement behaviors (physical activity, screen time, and sleep) are crucial in the development of overweight and obesity in young children. Yet, few studies have investigated the relationship between children’s movement behaviors and parenting practices because validated measures for use among families from LMIC are lacking. This study evaluated the psychometric properties of previously validated measures of young children’s physical activity, screen time, and sleep and parenting practices, translated and culturally adapted to Brazilian families. Methods A total of 78 parent-child dyads completed an interviewer-administered survey twice within 7 days. Child physical activity, sedentary time and sleep were concurrently measured using a wrist-worn accelerometer. Internal consistency and test-retest reliability was assessed using McDonald’s Omega and Intraclass Correlation Coefficients (ICC’s). Concurrent validity was evaluated by calculating Spearman correlations between parent reported child behaviors and accelerometer measured behaviors. Results Seventeen of the 19 parenting practices scales exhibited acceptable internal consistency reliability (Ω ≥ 0.70). Test-retest reliability ICC’s were acceptable and ranged from 0.82 - 0.99. Parent reported child physical activity was positively correlated with objectively measured total movement (rho= 0.29 - 0.46, p < .05) and energetic play (rho= 0.29 – 0.40, p < .05). Parent reported child screen time was positively correlated with objectively measured sedentary time; (rho = 0.26, p < .05), and inversely correlated with total movement (rho = - 0.39 – - 0.41, p < .05) and energetic play (rho = - 0.37 – - 0.41, p < .05). Parent reported night-time sleep duration was significantly correlated with accelerometer measured sleep duration on weekdays (rho = 0.29, p < .05), but not weekends. Conclusions Measurement tools to assess children’s movement behaviors and parenting practices, translated and culturally adapted for use in Brazilian families, exhibited acceptable evidence of concurrent validity, internal consistency, and test-retest reliability.


Scientifica ◽  
2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Mostafa Sadeghi ◽  
Homayoun Sadeghi-Bazargani ◽  
Shahrokh Amiri

Background. The Barkley Adult Attention Deficit/Hyperactivity Disorder (ADHD) Rating Scale-IV (BAARS-IV) was developed, and it demonstrated good psychometric properties. The BAARS-IV includes 27 questions on the symptoms of adult ADHD. The purpose of the present study is to investigate the psychometric testing of the Persian version of BAARS-IV among the elderlies in Tabriz City. Method. This cross-sectional study was conducted in Tabriz City—in the west of Iran—in 2015 via enrolling of 121 old-aged people. We did the process of translation and adaptation of BAARS-IV and examined its concurrent validity, internal consistency, and test-retest reliability. Result. The BAARS-IV demonstrated good internal consistency and test-retest reliability. Correlations between the BAARS-IV and the CAARS-S: SV were high and evidence supporting concurrent validity was revealed. Cronbach’s alpha for the overall scale and subscales stood at 0.89, 0.81, 0.66, 0.56, and 0.82, respectively. Conclusion. The Persian BAARS-IV showed acceptable reliability and validity. BAARS-IV was determined to be composed of internally consistent and psychometrically sound items.


2021 ◽  
Vol 21 (S1) ◽  
Author(s):  
Pongrác Ács ◽  
Réka Veress ◽  
Paulo Rocha ◽  
Tamás Dóczi ◽  
Bence László Raposa ◽  
...  

Abstract Background Physical inactivity is a global phenomenon in European welfare countries. Proper monitoring is essential to measure the physical activity level of the population. Methods In the Hungarian cohort of the European Physical Activity and Sport Monitoring System (EUPASMOS) project, our participants (N = 598) completed sociodemographic questions and the International Physical Activity Questionnaire – short form (IPAQ-SF) survey. The validity and reliability of the subjective measurement tool were examined, IPAQ-SF outcomes were contrasted against triaxial RM42 accelerometer wore for 7 consecutive days. Results The IPAQ-SF showed moderate internal consistency (Cronbach Alpha = 0.647). The concurrent validity of the IPAQ-SF to triaxial accelerometer indicated a significant weak-to-moderate correlation (R = 0.111–0.338, p = 0.042; p < 0.001). The test-retest reliability showed a significant correlation between two measurements (R = 0.788–0.981, p < 0.001). Conclusion The Hungarian version of the IPAQ-SF had excellent test-retest reliability, but low-to-fair concurrent validity for moderate and vigorous physical activity, walking and sitting time, as compared to the objective criterion measure among Hungarian adults.


Sign in / Sign up

Export Citation Format

Share Document