Implant surface roughness alterations induced by different prophylactic procedures: an in vitro study

2016 ◽  
Vol 28 (7) ◽  
pp. e16-e20 ◽  
Author(s):  
Carlo Cafiero ◽  
Marco Aglietta ◽  
Vincenzo Iorio-Siciliano ◽  
Giovanni E. Salvi ◽  
Andrea Blasi ◽  
...  
2020 ◽  
Vol 10 (15) ◽  
pp. 5231 ◽  
Author(s):  
Omer Cohen ◽  
Ofer Moses ◽  
Talia Gurevich ◽  
Roni Kolerman ◽  
Alina Becker ◽  
...  

This in-vitro study assessed the effect of an underdrilling implant placement protocol on the insertion torque, implant surface temperature and surface roughness (Sa) topography of the cervical microthreads of implants. Three groups of 25 implants (3.75 mm × 10 mm) were placed in osteotomies prepared in an artificial bone disc with final diameters of 3.65 mm according to the manufacturer’s instructions and in osteotomies prepared in accordance with an underdrilling protocol with final drill diameters of 3.2 and 2.8 mm (groups D3.65, D3.2, D2.8, respectively). Implants were inserted at a constant rate of 30 rpm. The surface temperature of the implants was measured with a thermal camera and temperature amplitude (Temp-Amp) was calculated by subtracting the room temperature from the measured implant surface temperature. Upon implant retrieval, coronal surface topography was assessed using a Nanofocus µsurf explorer and compared to a set of 25 new implants (control group). The differences between groups were compared using one-way ANOVA (p < 0.05). Significantly higher insertion torque, surface temperature values and significantly smaller average Sa values were measured in the implants inserted in undersized preparations. The highest temperature, insertion torque and Temp-Amp values and the largest decrease in Sa were measured in the D2.8 group. The lowest values were measured in the D3.65 group.


2014 ◽  
Vol 60 (5) ◽  
pp. 200-203
Author(s):  
Andreea Borş ◽  
Cristina Molnar-Varlam ◽  
Melinda Székely

Abstract Objective: The aim of this in vitro study was to evaluate the influence of erosive conditions on the wear resistance of aesthetic direct restorative materials. Methods: Six dental filling materials were tested: two composites (Filtek Z550 and X-tra fil), two compomers (Dyract Extra and Twinky Star) and two glass ionomers (Ketac Molar and Fuji II LC). Twenty disks (10mm×2mm) of each material were prepared (n=120) and kept in artificial saliva at 37˚C for 24 hours. Specimens were cycled in acidic soft drink (Coca-Cola) 5×/day, for 5’, over 30 days. Initial surface roughness ISR (Ra-μm) and final surface roughness FSR were measured using a profilometer. The wear rate was calculated as difference of final minus the initial roughness (ΔSR=FSR-ISR). For statistical analysis t-test and one-way ANOVA test were used by GraphPad Prism version 5.03 statistical software. The level of significance was set at p<0.05. Results: The erosive wear rates (mean±SD, μm) after exposure to acidic beverage were: 0.30±0.03 (Ketac Molar), 0.28±0.04 (Fuji II LC), 0.27±0.00 (Filtek Z550), 0.23±0.01 (X-tra fil), 0.20±0.00 (Twinky Star) and 0.14±0.01 Dyract Extra, respectively. There were significant differences between the tested materials (p<0.05). Conclusions: Dental filling materials had different behaviour under the same erosive condition, however all investigated aesthetic restorative materials showed surface degradation. These findings suggest that erosive wear resistance of tooth coloured restoratives could influence their longevity in intraoral acidic conditions. Acknowledgements: The study was supported by the Internal Research Grant no. 5/30.01.2013 of the University of Medicine and Pharmacy of Tirgu Mureş.


2021 ◽  
Vol 18 (1) ◽  
pp. 49
Author(s):  
Khushboo Goyal ◽  
SuparnaGanguly Saha ◽  
Anuj Bhardwaj ◽  
MainakKanti Saha ◽  
Kaustubh Bhapkar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document