Histological, radiological and histomorphometric evaluation of immediate vs. non-immediate loading of a zirconia implant with surface treatment in a dog model

2013 ◽  
Vol 25 (7) ◽  
pp. 826-830 ◽  
Author(s):  
Jose L. Calvo-Guirado ◽  
Antonio Aguilar-Salvatierra ◽  
Gerardo Gomez-Moreno ◽  
Javier Guardia ◽  
Rafael A. Delgado-Ruiz ◽  
...  
Author(s):  
Roseline Meshramkar ◽  
Praveen Shetty ◽  
Aishwarya Nayak ◽  
Gouri V. Anehosur

Zirconia implant treatment is currently overriding other prosthetic solutions in replacing anterior teeth in esthetic zone. Surface topography of biomaterial has major impact on osseointegration. Various chemical and physical modifications have been developed to improve osseointegration. This review focuses on different surface treatment of zirconia implant. Surface roughness and its effect on osseointegration.


2018 ◽  
Vol 27 (3) ◽  
pp. 282-287 ◽  
Author(s):  
Rafael Amorim Cavalcanti Siqueira ◽  
Ivete Aparecida de Mattias Sartori ◽  
Paulo Gustavo Freitas Santos ◽  
Márcio John Thiesen ◽  
Mylene Cassia Gonçalves ◽  
...  

2010 ◽  
Vol 21 (3) ◽  
pp. 308-315 ◽  
Author(s):  
J. L. Calvo-Guirado ◽  
A. J. Ortiz-Ruiz ◽  
B. Negri ◽  
L. López-Marí ◽  
C. Rodriguez-Barba ◽  
...  

2020 ◽  
Vol 9 (4) ◽  
pp. e27942662
Author(s):  
Patrícia Capellato ◽  
Cláudia Eliana Bruno Marino ◽  
Gilbert Silva ◽  
Lucas Victor Benjamim Vasconcelos ◽  
Rodrigo Perito Cardoso ◽  
...  

During the last decades, researchers have been growing the interest in surface treatment with an antimicrobial agent. Silver nanoparticles (AgNPs) are widely used in biomedical fields due to their potent antimicrobial activity. So, in this study was investigated silver particles (isles) coated on titanium surface for dental and orthopedic application. Silver particles coating process on titanium surface were performed via sputtering that is a plasma-assisted deposition technique with and titanium without treatment was applied as comparing standard. Plasma treatment parameters were optimized so that the result was not a thin film of Ag but dispersed particles of Ag on the Ti-cp surface. The alloy surfaces were investigated using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). In order to investigate antibacterial potential Staphylococcus aureus and Escherichia coli have been used at Agar diffusion assay. The results were analyzed by analysis of variance (ANOVA) in order to verify significant difference antimicrobial activity between samples that have shown no difference between the surfaces studied treatments. For silver deposition scattered particles (isles) over titanium surface for a 10-minute treatment, EDS revealed by silver clusters that the particles were not properly scattered onto surface, hence, the low effectiveness in antibacterial activity.


2013 ◽  
Vol 51 (10) ◽  
pp. 735-741
Author(s):  
Dong-Yong Kim ◽  
Eun-Wook Jeong ◽  
Kwun Nam Hui ◽  
Youngson Choe ◽  
Jung-Ho Han ◽  
...  

2008 ◽  
Vol 128 (5) ◽  
pp. 339-342
Author(s):  
Dai Ling ◽  
Yin Ting ◽  
Lin Fuchang ◽  
Yan Fei

Sign in / Sign up

Export Citation Format

Share Document