Immediate implant placement combined with maxillary sinus floor elevation utilizing the transalveolar approach and nonsubmerged healing for failing teeth in the maxillary molar area: A randomized controlled trial clinical study with one‐year follow‐up

2019 ◽  
Vol 21 (3) ◽  
pp. 462-472 ◽  
Author(s):  
Hanqing Liu ◽  
Renzhang Liu ◽  
Mingzhen Wang ◽  
Jianjun Yang
2018 ◽  
Vol 2 (2) ◽  
pp. 495-498
Author(s):  
Jorge Gatica ◽  
Claudio Garayar

The sinus lift is a procedure that is used frequently in oral surgery, different techniques exist to perform this procedure approaches, which allow the surgeon to give a sufficient bone height for planning a rehabilitative treatment with implant at the required site. In this case the unilateral lifting of the maxillary sinus floor by buccal bone window, with subsequent implant placement and lyophilized human bone in a single surgical procedure.


2021 ◽  
Vol 11 (17) ◽  
pp. 8244
Author(s):  
Sang-Woon Lee ◽  
Young-Wook Park

The aims of this study were to propose a minimally invasive lateral approach technique for maxillary sinus floor elevation (MSFE) with simultaneous implant placement and to evaluate the surgical outcome and complications of this technique. This study reviewed 49 surgeries of MSFE with simultaneous implant placement (n = 83) using a minimally invasive lateral approach. A circular shape window with a diameter of 5 to 6 mm and an area of 20–30 mm2 was made on the lateral wall of the maxillary sinus. After elevation of the Schneiderian membrane, the xenograft was used for bone grafting. The MSFE was possible with a minimum-sized window in 47 of 49 cases. For the remaining 2 cases, MSFE with a minimum-sized window was failed. In one case, it was expanded to be more than 30 mm2 to repair the membrane perforation. In another case, MSFE was performed by forming two minimum-sized windows. Post-operative bleeding after MSFE occurred in one anticoagulant-treated patient. There was no failed implant during the follow-up period (mean 22 months). A minimally invasive lateral approach through a small circular window with a diameter of 5 to 6 mm is a feasible and safe technique for MSFE with simultaneous implant placement.


Materials ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1471
Author(s):  
Wilhelmus F. Bouwman ◽  
Nathalie Bravenboer ◽  
Christiaan M. ten Bruggenkate ◽  
Francis A. Eijsackers ◽  
Najada Stringa ◽  
...  

This study evaluates the radiological changes in tissue height after maxillary sinus floor elevation (MSFE) using three types of calcium phosphate ceramics over a period of up to 5 years after dental implant placement. In 163 patients, MSFE was performed. Three groups of patients were distinguished and treated based on the type of calcium phosphate ceramic used and radiologically evaluated: 40 patients with β-tricalcium phosphate (β-TCP), 76 patients with biphasic calcium phosphate (BCP) 20% hydroxyapatite (HA)-80% β-TCP, and 47 patients with BCP 60% HA-40% β-TCP. Radiological measurements were performed on panoramic radiographs at several time points up to 5 years after dental implant placement. After MSFE, a slow decrease in tissue height measured over time was seen in all three study groups. Resorption of the grafted bone substitutes was more prominent in β-TCP than in BCP ceramics with an HA component (60/40 and 20/80). Loss of tissue height after 5 years was lowest in BCP 60/40 and highest in β-TCP. This radiological study shows a predictable and comparable behavior of the slow decrease in tissue height over time for all three types of calcium phosphate ceramics used in MSFE. The fraction of HA in calcium phosphate ceramics and dental implant loading seems to be beneficial for tissue height maintenance after MSFE.


Sign in / Sign up

Export Citation Format

Share Document