Histological Evaluation of Bone Formation Adjacent to Dental Implants with a Novel Apical Chamber Design: Preliminary Data in the Rabbit Model

2013 ◽  
Vol 17 (3) ◽  
pp. 453-460 ◽  
Author(s):  
Luiz Meirelles ◽  
Per-Ingvar Brånemark ◽  
Tomas Albrektsson ◽  
Changyong Feng ◽  
Carina Johansson
2020 ◽  
Author(s):  
Hendrik Naujokat ◽  
Klaas Loger ◽  
Juliane Schulz ◽  
Yahya Açil ◽  
Jörg Wiltfang

Aim: This study aimed to evaluate two different vascularized bone flap scaffolds and the impact of two barrier membranes for the reconstruction of critical-size bone defects. Materials & methods: 3D-printed scaffolds of biodegradable calcium phosphate and bioinert titanium were loaded with rhBMP-2 bone marrow aspirate, wrapped by a collagen membrane or a periosteum transplant and implanted into the greater omentum of miniature pigs. Results: Histological evaluation demonstrated significant bone formation within the first 8 weeks in both scaffolds. The periosteum transplant led to enhanced bone formation and a homogenous distribution in the scaffolds. The omentum tissue grew out a robust vascular supply. Conclusion: Endocultivation using 3D-printed scaffolds in the greater omentum is a very promising approach in defect-specific bone tissue regeneration.


Materials ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1814
Author(s):  
Plinio Mendes Senna ◽  
Carlos Fernando de Almeida Barros Mourão ◽  
Rafael Coutinho Mello-Machado ◽  
Kayvon Javid ◽  
Pietro Montemezzi ◽  
...  

Silane-coating strategy has been used to bind biological compounds to the titanium surface, thereby making implant devices biologically active. However, it has not been determined if the presence of the silane coating itself is biocompatible to osseointegration. The aim of the present study was to evaluate if silane-coating affects bone formation on titanium using a rabbit model. For this, titanium screw implants (3.75 by 6 mm) were hydroxylated in a solution of H2SO4/30% H2O2 for 4 h before silane-coating with 3-aminopropyltriethoxysilane (APTES). A parallel set of titanium screws underwent only the hydroxylation process to present similar acid-etched topography as a control. The presence of the silane on the surface was checked by x-ray photoelectron spectroscopy (XPS), with scanning electron microscopy (SEM) and atomic force microscopy (AFM). A total of 40 titanium screws were implanted in the tibia of ten New Zealand rabbits in order to evaluate bone-to-implant contact (BIC) after 3 weeks and 6 weeks of healing. Silane-coated surface presented higher nitrogen content in the XPS analysis, while micro- and nano-topography of the surface remained unaffected. No difference between the groups was observed after 3 and 6 weeks of healing (p > 0.05, independent t-test), although an increase in BIC occurred over time. These results indicate that silanization of a titanium surface with APTES did not impair the bone formation, indicating that this can be a reliable tool to anchor osteogenic molecules on the surface of implant devices.


2020 ◽  
Vol 18 ◽  
pp. 228080002097517
Author(s):  
Yuan-ming Geng ◽  
Dong-ni Ren ◽  
Shu-yi Li ◽  
Zong-yi Li ◽  
Xiao-qing Shen ◽  
...  

Background: Poly Ether Ether Ketone (PEEK) has been considered as a potential alternative material for endosseous dental implants, for its low elastic modulus, biocompatibility, and low cost in customized device manufacture. Hydroxyapatite-incorporation is supposed to improve the poor osseointegration of PEEK. Methods: In the present study we analyzed the in vivo response of hydroxyapatite-incorporated PEEK (PEEK-HA) implants in canine tibia. PEEK-HA and PEEK implants were implanted and were examined 4 weeks and 12 weeks after implantation with radiology and histology. Commercial titanium dental implants served as controls. Results: The ratio of bone volume to tissue volume of PEEK-HA implants was higher than that of PEEK implants 4 weeks after implantation in the μ-CT analysis. The bone implant contact of PEEK and PEEK-HA implants showed no statistical difference in the histological examination, but newly-formed bone around PEEK-HA implants showed more signs of mineralization than that around PEEK implants. Conclusion: The study suggested that bone formation was improved with hydroxyapatite-incorporation in PEEK. Hydroxyapatite-incorporated PEEK implants may represent a potential material for endosseous dental implant.


2015 ◽  
Vol 5 (1) ◽  
Author(s):  
Philipp S. Lienemann ◽  
Stéphanie Metzger ◽  
Anna-Sofia Kiveliö ◽  
Alain Blanc ◽  
Panagiota Papageorgiou ◽  
...  

Abstract Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (<1 mm). Herein, we employ modular designed poly(ethylene glycol)-based hydrogels that release bone morphogenetic protein to guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials.


2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Antonio Scarano ◽  
Ezio Crocetta ◽  
Alessandro Quaranta ◽  
Felice Lorusso

Background. Pure titanium continues to be the first choice for dental implants and represents the gold standard for their biocompatibility and physical and mechanical characteristics, while the titanium alloy (Ti6Al4V) has good mechanical properties. The surface structure of the titanium oxide layer formation on the surface influences and improves the bone response around dental implants. Purpose. The purpose of this study is to evaluate the influence of a thermal treatment of Ti6Al4V implant surfaces and the bone healing response in a rabbit model. Methods. Altogether sixteen implants with same design were inserted into the distal femoral metaphysis. A screw (13 mm long, 4 mm in diameter) was inserted in an implant bed. Each rabbit received two implants, one in the left femur and one in the right femur. The samples were histologically and histomorphometrically evaluated at 8 weeks. Results. A statistically significant difference (p = 0.000034) was present histologically in the percentages of bone-implant contact (BIC) between the test group (BIC = 69.25±4.49%.) and control group (BIC = 56.25 ± 4.8%) by one-way analysis of variance (ANOVA). Significance was set at p ≤ 0.05. Conclusions. The outcome of the present study indicates a novel approach to improving bone healing around titanium implants.


Author(s):  
Carlos Fernando Almeida da Silva ◽  
Tayná Toder Santos ◽  
Idiberto José Zotarelli Filho ◽  
Elias Naim Kassis

Introduction: When a dental element is lost in the posterior region of the maxilla, there is natural reabsorption of the alveolar process and at the same time there will be pneumatization of the maxillary sinus. It will increase its volume towards the place where the roots existed and this will often make it difficult or impossible to restore implants in place. For this reason, the procedure for elevating the floor of the maxillary sinus or short implants should be performed when possible. In this context, allogeneic, xenogenous, and alloplastic bone grafts are an alternative for the treatment of bone defects in the jaws, since they avoid the need for a second surgical access. However, due to the need for processing to eliminate antigenic components, these grafts are only osteoconductive with a lower bone formation potential compared to autogenous bone grafts. Also, in this context, in the last 20 years, platelet concentrates have been proposed as regenerative materials in tissue regeneration procedures. Among the platelet concentrates proposed in the literature, PRP and FRP are found to act as autogenous platelet aggregates with osteoinductive properties. Objective: The present study aimed to conduct a wide literature review on maxillary sinus surgery using fibrin-rich plasma. Methods: Experimental and clinical studies (case reports, retrospective, prospective and randomized) with qualitative and/or quantitative analysis were included. Results: The total of 48 articles were found involving Maxillary sinus surgery, Fibrin-rich plasma, and Biomaterials, of which 22 were selected to compose the present study. Conclusion: Based on the literary findings, it was shown that the FRP is favorable for bone formation processes for dental implants, especially when combined with xenografts.


Materials ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 1993 ◽  
Author(s):  
Kunio Ishikawa ◽  
Youji Miyamoto ◽  
Akira Tsuchiya ◽  
Koichiro Hayashi ◽  
Kanji Tsuru ◽  
...  

Three commercially available artificial bone substitutes with different compositions, hydroxyapatite (HAp; Neobone®), carbonate apatite (CO3Ap; Cytrans®), and β-tricalcium phosphate (β-TCP; Cerasorb®), were compared with respect to their physical properties and tissue response to bone, using hybrid dogs. Both Neobone® (HAp) and Cerasorb® (β-TCP) were porous, whereas Cytrans® (CO3Ap) was dense. Crystallite size and specific surface area (SSA) of Neobone® (HAp), Cytrans® (CO3Ap), and Cerasorb® (β-TCP) were 75.4 ± 0.9 nm, 30.8 ± 0.8 nm, and 78.5 ± 7.5 nm, and 0.06 m2/g, 18.2 m2/g, and 1.0 m2/g, respectively. These values are consistent with the fact that both Neobone® (HAp) and Cerasorb® (β-TCP) are sintered ceramics, whereas Cytrans® (CO3Ap) is fabricated in aqueous solution. Dissolution in pH 5.3 solution mimicking Howship’s lacunae was fastest in CO3Ap (Cytrans®), whereas dissolution in pH 7.3 physiological solution was fastest in β-TCP (Cerasorb®). These results indicated that CO3Ap is stable under physiological conditions and is resorbed at Howship’s lacunae. Histological evaluation using hybrid dog mandible bone defect model revealed that new bone was formed from existing bone to the center of the bone defect when reconstructed with CO3Ap (Cytrans®) at week 4. The amount of bone increased at week 12, and resorption of the CO3Ap (Cytrans®) was confirmed. β-TCP (Cerasorb®) showed limited bone formation at week 4. However, a larger amount of bone was observed at week 12. Among these three bone substitutes, CO3Ap (Cytrans®) demonstrated the highest level of new bone formation. These results indicate the possibility that bone substitutes with compositions similar to that of bone may have properties similar to those of bone.


2017 ◽  
Vol 45 (9) ◽  
pp. 2019-2027 ◽  
Author(s):  
Dong-Sam Suh ◽  
Jun-Keun Lee ◽  
Ji-Chul Yoo ◽  
Sang-Hun Woo ◽  
Ga-Ram Kim ◽  
...  

Background: Failure of rotator cuff healing is a common complication despite the rapid development of surgical repair techniques for the torn rotator cuff. Purpose: To verify the effect of atelocollagen on tendon-to-bone healing in the rabbit supraspinatus tendon compared with conventional cuff repair. Study Design: Controlled laboratory study. Methods: A tear of the supraspinatus tendon was created and repaired in 46 New Zealand White rabbits. They were then randomly allocated into 2 groups (23 rabbits per group; 15 for histological and 8 for biomechanical test). In the experimental group, patch-type atelocollagen was implanted between bone and tendon during repair; in the control group, the torn tendon was repaired without atelocollagen. Each opposite shoulder served as a sham (tendon was exposed only). Histological evaluation was performed at 4, 8, and 12 weeks. Biomechanical tensile strength was tested 12 weeks after surgery. Results: Histological evaluation scores of the experimental group (4.0 ± 1.0) were significantly superior to those of the control group (7.7 ± 2.7) at 12 weeks ( P = .005). The load to failure was significantly higher in the experimental group (51.4 ± 3.9 N) than in the control group (36.4 ± 5.9 N) ( P = .001). Conclusion: Histological and biomechanical studies demonstrated better results in the experimental group using atelocollagen in a rabbit model of the supraspinatus tendon tear. Clinical Relevance: Atelocollagen patch could be used in the cuff repair site to enhance healing.


Sign in / Sign up

Export Citation Format

Share Document