scholarly journals Four-year outcomes from a multiparametric magnetic resonance imaging (MRI)-based active surveillance programme: PSA dynamics and serial MRI scans allow omission of protocol biopsies

2018 ◽  
Vol 123 (3) ◽  
pp. 429-438 ◽  
Author(s):  
Kevin Michael Gallagher ◽  
Edward Christopher ◽  
Andrew James Cameron ◽  
Scott Little ◽  
Alasdair Innes ◽  
...  
Author(s):  
Donald W. Paty

ABSTRACT:Magnetic resonance imaging (MRI) has been shown to be a good method of visualizing the lesions in MS. We have studied several applications of MRI to the evaluation of patients and experimental models. In diagnosis, MRI is the most sensitive test for the demonstration of dissemination of lesions in space. Pathological correlation studies show that MRI reliably measures the extent of chronic demyelination. Experimental studies show that MRI detects acute inflammatory lesions and measures their evolution. MRI also is a reliable measure of the extent of the MS process, serial MRI scans detect evidence of disease activity in MS not always disclosed by clinical evaluation. MRI will have an enormous future impact on the evaluation of patients in clinical studies and in understanding the evolution of pathological processes.


Pain Practice ◽  
2021 ◽  
Author(s):  
Marco Reining ◽  
Dirk Winkler ◽  
Joachim Boettcher ◽  
Juergen Meixensberger ◽  
Michael Kretzschmar

2017 ◽  
Vol 71 (2) ◽  
pp. 174-180 ◽  
Author(s):  
Ting Martin Ma ◽  
Jeffrey J. Tosoian ◽  
Edward M. Schaeffer ◽  
Patricia Landis ◽  
Sacha Wolf ◽  
...  

Author(s):  
Cheng-Yi Wang ◽  
Wei-Chou Chang ◽  
Hsin-Hung Huang ◽  
Wei-Kuo Chang ◽  
Yu-Lueng Shih ◽  
...  

Objective: Not all endoscopic clips are compatible with magnetic resonance imaging (MRI). The aim of this study is to investigate the safety of MRI-incompatible endoscopic clips in patients undergoing MRI scans. Methods: We retrospectively reviewed the medical records of patients who had received endoscopic clip placement of Olympus Long Clip MRI-incompatible clips and then had undergone MRI scans within two weeks in our hospital between 2014 and 2019. Results: A total of 44,292 patients had undergone an MRI examination at our hospital. Only 15 patients had MRI scans within two weeks after the endoscopic clip placement. Their median age was 65.5 years, and 12 of the 15 patients were men. At the time of the clip placement and MRI scan, four patients were taking anti-coagulation or anti-platelet agents. The indication for endoscopic clip placement of the 15 patients was mucosal/submucosal defect or hemorrhage and colonic perforation. Endoscopic clips were placed in the colon of 14 patients and in the stomach of only one patient for gastric hemorrhage. One patient experienced clip migration and three displayed artifacts in abdominal images. No patient complications of mortality, hemorrhage, or organ perforation occurred. Conclusion: No serious adverse event occurred during MRI scans of patients with MRI-incompatible clips in this study, suggesting that MRI-incompatible clips may be safe to use in MRI scans. However, this does not guarantee the safety of the Long Clip for MRI scans, as further tests are needed to verify that this clip is safe for use during MRI.


Hand ◽  
2022 ◽  
pp. 155894472110643
Author(s):  
Jimmy H. Daruwalla ◽  
Jan Skrok ◽  
Mitchell A. Pet ◽  
Aviram M. Giladi ◽  
James P. Higgins

Background: The medial femoral trochlea (MFT) osteochondral flap is employed for reconstruction of unsalvageable scaphoid proximal pole nonunions. The convex surface of the cartilage-bearing proximal trochlea is used to replace the similarly contoured proximal scaphoid and articulate with the concave scaphoid fossa of the radius. A magnetic resonance imaging (MRI) comparison of the shape of the MFT as it relates to the native proximal scaphoid has not been previously performed. Our study aimed to quantifiably compare the shape of the MFT, proximal scaphoid, and scaphoid fossa. Methods: Using imaging processing software, we measured radius of curvature of the articular segments in MRI scans of 10 healthy subjects’ wrists and knees. Results: Compared with the scaphoid fossa, average ratio of the radius of circumference of the proximal scaphoid was 0.79 and 0.78 in the coronal and sagittal planes, respectively. Compared with the scaphoid fossa, average ratio of the radius of circumference of the MFT was 0.98 and 1.31 in the coronal and sagittal planes, respectively. The radius of curvature of the MFT was larger than the proximal scaphoid, in the coronal and sagittal planes. In the coronal plane, the MFT radius of curvature is nearly identical to the scaphoid fossa, a closer match than the scaphoid itself. In the sagittal plane, the radius of curvature of the MFT was larger than the radius of curvature of the scaphoid fossa. Conclusions: Our data suggest that the radius of curvature, in the sagittal and coronal planes, of the MFT and proximal scaphoid is disparate.


Sign in / Sign up

Export Citation Format

Share Document