Combined use of Kirschner wires and hinged external fixator for capitellar and trochlear fractures: a minimum 24-month follow-up

2018 ◽  
Vol 89 (3) ◽  
pp. 196-200
Author(s):  
Shu-Kun He ◽  
Si-Chun Zhao ◽  
Jin-Hai Guo ◽  
Ting-Wu Qin ◽  
Fu-Guo Huang
2020 ◽  
Author(s):  
Hongfeng Sheng ◽  
Weixing Xu ◽  
Bin Xu ◽  
Hongpu Song ◽  
Di Lu ◽  
...  

UNSTRUCTURED The retrospective study of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures provides a theoretical basis for the application of this technology. The paper collected 28 patients with tibiofibular fractures from the Department of Orthopaedics in our hospital from March 2015 to June 2018. After the treatment, the follow-up evaluation of Taylor's three-dimensional external fixator for the treatment of tibiofibular fractures and concurrency the incidence of the disease, as well as the efficacy and occurrence of the internal fixation of the treatment of tibial fractures in our hospital. The results showed that Taylor's three-dimensional external fixator was superior to orthopaedics in the treatment of tibiofibular fractures in terms of efficacy and complications. To this end, the thesis research can be concluded as follows: Taylor three-dimensional external fixation in the treatment of tibiofibular fractures is more effective, and the incidence of occurrence is low, is a new technology for the treatment of tibiofibular fractures, it is worthy of clinical promotion.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yanshi Liu ◽  
Maimaiaili Yushan ◽  
Zhenhui Liu ◽  
Jialin Liu ◽  
Chuang Ma ◽  
...  

Abstract Background The Ilizarov segmental bone transport technique can be applied in the reconstruction of the bone defects with less invasive fashion and more versatility compared to other methods, while most studies were focused on the lower extremity. The purpose of this study was to evaluate the effectiveness of the Ilizarov segmental bone transport technique in the treatment of diaphyseal forearm bone defects caused by infection. Methods This study included 12 patients with diaphyseal forearm bone defects caused by infection, who underwent bone transport procedures using the monolateral external fixator at our institution from January 2010 to January 2018, including 10 males and 2 females with a mean age of 39 years (range 23–57 years). Patient’s demographic data and clinical outcomes at least two years follow-up after removing the external fixator were collected and retrospectively analyzed. The functional results were evaluated by the questionnaire of Disability of Arm, Shoulder and Hand (DASH) and the modified Mayo wrist score (MWS) at the final follow-up. Results There were 10 radii and 2 ulnae bone transport procedures collected. The average defect size was 5.1 cm (4-6.5 cm). All patients were successfully followed up with a mean period of 28.2 months (24 to 36 months) and achieved infection-free union. There was no recurrence of infection observed. The mean external fixation time was 232.6 days (182 to 276 days), and the mean external fixation index was 46.3 days/cm (40.9 to 61.8 days/cm). The mean DASH score was 30.6(18 to 49) preoperative, while 13.8 (5 to 26) at the final follow-up. The average modified MWS improved from 68.8 (55 to 80) pre-operatively to 83.8 (65 to 90) at the final follow-up. All the differences between the preoperative and final scores were statistically significant (p < 0.05). Almost all the patients achieved satisfactory clinical outcomes and were able to perform activities of daily living. Conclusions Ilizarov segmental bone transport technique is an alternative and effective method for the treatment of diaphyseal forearm bone defects caused by infection, and this method acquired satisfactory clinical outcomes.


2021 ◽  
pp. 24-28
Author(s):  
L. S. Kruglova ◽  
N. V. Gryazeva

The article presents the results of evaluating the effectiveness of the combined use of combined oral contraceptives (COC) and Skinoren cream in severe papular-pustular and moderate nodular-cystic acne.Material and methods. Patients of the first group (n = 11) used COC and an external antibacterial drug two times a day for the treatment of acne. Patients of the second group (n = 12) used COC and an external drug containing azelaic acid (Skinoren) for the treatment of acne two times a day. The duration of follow-up was 6 months. The efficiency assessment was carried out taking into account the dynamics of the indicators of the IGA (Investors Global Assessment) scale. The Manchester Scar Scale (MSS) was used to assess the effectiveness of post-acne correction. In addition, the effectiveness was evaluated based on the results of the mexametry.Results. When evaluating IGA in the comparison groups in patients with severe papulopustular acne and moderate nodular cystic acne, comparable efficacy was noted, but the best results were recorded in the COC + Skinoren group (p < 0.05). No effect and deterioration of the condition were observed in any group. When assessing MSS, the most pronounced changes were observed in patients of group 2, where the combination of COC + Skinoren was used. So, in group 1, the severity of scars decreased by 42.3 %, in group 2 by 48.2 % (p < 0.05). The evaluation of the results of the mexametry showed a more pronounced decrease in the amount of pigment in patients from group 2. When studying the results of the severity of erythema, the dynamics similar to the severity of the pigment was obtained. The best result was registered in group 2 (COC + Skinoren) (p < 0.05).Conclusions. The combined use of COC and Skinoren cream for severe papular-pustular and moderate nodular-cystic acne has proven to be an effective method both in relation to the number of inflammatory and retention elements, and in relation to hyperpigmentation.


2017 ◽  
Vol 2 (3) ◽  
pp. 2473011417S0002
Author(s):  
Hwa Jun Kang ◽  
Hong-Geun Jung ◽  
Jong-Soo Lee ◽  
Sungwook Kim ◽  
Mao Yuan Sun

Category: Bunion Introduction/Purpose: Kirschner-wires fixation, sometimes we have encountered pin irritation or pull-out. This is the reason why we consider additional fixation. Moreover, there are few reports according to comparison of fixation method, and Most of them focused on comparison K-wires or screw fixation only. Purpose of study is to compare clinical and radiographic outcome between Kirschner-wires only and combined screw fixation. Methods: The study included two different groups according to fixation methods. One with Kirschner-wires fixation (KW group) included 117 feet(of 98 patients), the other with combined screw fixation (KWS group) 56 feet (of 40 patients) with moderate to severe hallux valgus. Clinically, the preoperative and final follow-up visual analog scale (VAS) pain scores, the preoperative and final follow-up American Orthopaedic Foot & Ankle Society (AOFAS) hallux metatarsophalangeal (MTP)-interphalangeal (IP) scores, and patient satisfaction after the surgery were evaluated. Radiographically, the hallux valgus angle (HVA), intermetatarsal angle (IMA), medial sesamoid position (MSP), and first to fifth metatarsal width (1-5MTW) were analyzed before and after surgery. Results: The mean AOFAS score improved preoperative 65.5 to 95.3 at final follow up in group A, while preoperative 56.5 to 88.6 at final follow up. Pain VAS decreased from 5.7 to 0.5 in group A, whereas from 6.2 to 1.6 in group B. The mean HVA all improved from preoperative 38.5 to 9.3 at final follow up in group A and 34.7 to 9.1 in group B. The mean IMA and MSP also improved significantly at final follow up. In comparative analysis, the IMA did not show significant difference between postoperative and final state in group A, while showed significant increase in group B. Conclusion: We achieved favorable clinical and radiographic outcomes with minimal complications in patient with moderate to severe hallux valgus in both groups. However, this study shows no statistically significant difference in IMA during follow-up period and lower recurrence rate. Therefore we need to consider combined fixation method to provide better stability and can expect lower recurrence rate.


2009 ◽  
Vol 44 (4) ◽  
pp. 336-341
Author(s):  
Alberto Naoki Miyazaki ◽  
Marcelo Fregoneze ◽  
Pedro Doneux Santos ◽  
Luciana Andrade da Silva ◽  
Nelson Gennaro Junior ◽  
...  

2018 ◽  
Vol 04 (01) ◽  
pp. e29-e33 ◽  
Author(s):  
Jose Couceiro ◽  
Higinio Ayala ◽  
Manuel Sanchez ◽  
Maria De la Red ◽  
Olga Velez ◽  
...  

Purpose The purpose of our study is to compare the intramedullary fixation of metacarpal fractures with cannulated headless screws and antegrade Kirschner wires in terms of final total active motion, grip strength, patient-related outcomes, need for casting, and return to work times. Methods The authors performed a retrospective review of the hospital records. Thirty fractures were included in the study, 19 in the screw fixation group, and 11 in the Kirschner wire group. Grip strength, and total active motion, was measured at the latest follow-up for both the injured and contralateral hand. Pain was measured on the visual analog scale. Patients were requested to fill a Quick disabilities of the arm and hand score (DASH) questionnaire at the latest follow-up. Satisfaction was measured on a scale from 0 to 10. The time to return to work was quantified from the accident to the point when the patient was back to active duty. Postoperative casting time was also quantified. Results The authors did not find any differences between the two groups in total active motion, grip strength, pain, satisfaction, or Quick DASH scores. We did find a difference in the return to work and casting times; these appeared to be shorter in the screw group. Conclusion Due to the small number of cases, we have been unable to clearly conclude that there were any benefits in the application of one particular technique when compared with the other.


1997 ◽  
Vol 32 (7) ◽  
pp. 1710
Author(s):  
Sung Do Cho ◽  
Dong Bae Shin ◽  
Yong Sun Cho ◽  
Bum Soo Kim ◽  
Tae Woo Park ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document