Efficiency Gain for RoHC Compressor Implementations with Dynamic Configuration

Author(s):  
Mate Tomoskozi ◽  
Patrick Seeling ◽  
Peter Ekler ◽  
Frank H. P. Fitzek
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
I. E. Ceyisakar ◽  
N. van Leeuwen ◽  
Diederik W. J. Dippel ◽  
Ewout W. Steyerberg ◽  
H. F. Lingsma

Abstract Background There is a growing interest in assessment of the quality of hospital care, based on outcome measures. Many quality of care comparisons rely on binary outcomes, for example mortality rates. Due to low numbers, the observed differences in outcome are partly subject to chance. We aimed to quantify the gain in efficiency by ordinal instead of binary outcome analyses for hospital comparisons. We analyzed patients with traumatic brain injury (TBI) and stroke as examples. Methods We sampled patients from two trials. We simulated ordinal and dichotomous outcomes based on the modified Rankin Scale (stroke) and Glasgow Outcome Scale (TBI) in scenarios with and without true differences between hospitals in outcome. The potential efficiency gain of ordinal outcomes, analyzed with ordinal logistic regression, compared to dichotomous outcomes, analyzed with binary logistic regression was expressed as the possible reduction in sample size while keeping the same statistical power to detect outliers. Results In the IMPACT study (9578 patients in 265 hospitals, mean number of patients per hospital = 36), the analysis of the ordinal scale rather than the dichotomized scale (‘unfavorable outcome’), allowed for up to 32% less patients in the analysis without a loss of power. In the PRACTISE trial (1657 patients in 12 hospitals, mean number of patients per hospital = 138), ordinal analysis allowed for 13% less patients. Compared to mortality, ordinal outcome analyses allowed for up to 37 to 63% less patients. Conclusions Ordinal analyses provide the statistical power of substantially larger studies which have been analyzed with dichotomization of endpoints. We advise to exploit ordinal outcome measures for hospital comparisons, in order to increase efficiency in quality of care measurements. Trial registration We do not report the results of a health care intervention.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3768
Author(s):  
Yongshou Yang ◽  
Shiliang Fang

Broadband acoustic Doppler current profiler (ADCP) is widely used in agricultural water resource explorations, such as river discharge monitoring and flood warning. Improving the velocity estimation accuracy of broadband ADCP by adjusting the waveform parameters of a phase-encoded signal will reduce the velocity measurement range and water stratification accuracy, while the promotion of stratification accuracy will degrade the velocity estimation accuracy. In order to minimize the impact of these two problems on the measurement results, the ADCP waveform optimization problem that satisfies the environment constraints while keeping high velocity estimation accuracy or stratification accuracy is studied. Firstly, the relationship between velocity or distance estimation accuracy and signal waveform parameters is studied by using an ambiguity function. Secondly, the constraints of current velocity range, velocity distribution and other environmental characteristics on the waveform parameters are studied. For two common measurement applications, two dynamic configuration methods of waveform parameters with environmental adaptability and optimal velocity estimation accuracy or stratification accuracy are proposed based on the nonlinear programming principle. Experimental results show that compared with the existing methods, the velocity estimation accuracy of the proposed method is improved by more than 50%, and the stratification accuracy is improved by more than 22%.


2021 ◽  
Vol 11 (2) ◽  
pp. 716
Author(s):  
Ruibiao Chen ◽  
Fangxing Shu ◽  
Kai Lei ◽  
Jianping Wang ◽  
Liangjie Zhang

Non-orthogonal multiple access (NOMA) has been considered a promising technique for the fifth generation (5G) mobile communication networks because of its high spectrum efficiency. In NOMA, by using successive interference cancellation (SIC) techniques at the receivers, multiple users with different channel gain can be multiplexed together in the same subchannel for concurrent transmission in the same spectrum. The simultaneously multiple transmission achieves high system throughput in NOMA. However, it also leads to more energy consumption, limiting its application in many energy-constrained scenarios. As a result, the enhancement of energy efficiency becomes a critical issue in NOMA systems. This paper focuses on efficient user clustering strategy and power allocation design of downlink NOMA systems. The energy efficiency maximization of downlink NOMA systems is formulated as an NP-hard optimization problem under maximum transmission power, minimum data transmission rate requirement, and SIC requirement. For the approximate solution with much lower complexity, we first exploit a quick suboptimal clustering method to assign each user to a subchannel. Given the user clustering result, the optimal power allocation problem is solved in two steps. By employing the Lagrangian multiplier method with Karush–Kuhn–Tucker optimality conditions, the optimal power allocation is calculated for each subchannel. In addition, then, an inter-cluster dynamic programming model is further developed to achieve the overall maximum energy efficiency. The theoretical analysis and simulations show that the proposed schemes achieve a significant energy efficiency gain compared with existing methods.


Sensors ◽  
2021 ◽  
Vol 21 (11) ◽  
pp. 3587
Author(s):  
Ezequiel Simeoni ◽  
Eugenio Gaeta ◽  
Rebeca I. García-Betances ◽  
Dave Raggett ◽  
Alejandro M. Medrano-Gil ◽  
...  

Internet of Things (IoT) technologies are already playing an important role in our daily activities as we use them and rely on them to increase our abilities, connectivity, productivity and quality of life. However, there are still obstacles to achieving a unique interface able to transfer full control to users given the diversity of protocols, properties and specifications in the varied IoT ecosystem. Particularly for the case of home automation systems, there is a high degree of fragmentation that limits interoperability, increasing the complexity and costs of developments and holding back their real potential of positively impacting users. In this article, we propose implementing W3C’s Web of Things Standard supported by home automation ontologies, such as SAREF and UniversAAL, to deploy the Living Lab Gateway that allows users to consume all IoT devices from a smart home, including those physically wired and using KNX® technology. This work, developed under the framework of the EC funded Plan4Act project, includes relevant features such as security, authentication and authorization provision, dynamic configuration and injection of devices, and devices abstraction and mapping into ontologies. Its deployment is explained in two scenarios to show the achieved technology’s degree of integration, the code simplicity for developers and the system’s scalability: one consisted of external hardware interfacing with the smart home, and the other of the injection of a new sensing device. A test was executed providing metrics that indicate that the Living Lab Gateway is competitive in terms of response performance.


2016 ◽  
Vol 139 (3) ◽  
Author(s):  
Bilal Hassan ◽  
Oghare Victor Ogidiama ◽  
Mohammed N. Khan ◽  
Tariq Shamim

A thermodynamic model and parametric analysis of a natural gas-fired power plant with carbon dioxide (CO2) capture using multistage chemical looping combustion (CLC) are presented. CLC is an innovative concept and an attractive option to capture CO2 with a significantly lower energy penalty than other carbon-capture technologies. The principal idea behind CLC is to split the combustion process into two separate steps (redox reactions) carried out in two separate reactors: an oxidation reaction and a reduction reaction, by introducing a suitable metal oxide which acts as an oxygen carrier (OC) that circulates between the two reactors. In this study, an Aspen Plus model was developed by employing the conservation of mass and energy for all components of the CLC system. In the analysis, equilibrium-based thermodynamic reactions with no OC deactivation were considered. The model was employed to investigate the effect of various key operating parameters such as air, fuel, and OC mass flow rates, operating pressure, and waste heat recovery on the performance of a natural gas-fired power plant with multistage CLC. The results of these parameters on the plant's thermal and exergetic efficiencies are presented. Based on the lower heating value, the analysis shows a thermal efficiency gain of more than 6 percentage points for CLC-integrated natural gas power plants compared to similar power plants with pre- or post-combustion CO2 capture technologies.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1094
Author(s):  
Scott Stainton ◽  
Martin Johnston ◽  
Satnam Dlay ◽  
Paul Anthony Haigh

Neural networks and their application in communication systems are receiving growing attention from both academia and industry. The authors note that there is a disconnect between the typical objective functions of these neural networks with regards to the context in which the neural network will eventually be deployed and evaluated. To this end, a new loss function is proposed and shown to increase the performance of neural networks when implemented in a communication system compared to previous methods. It is further shown that a ‘split complex’ approach used by many implementations can be improved via formalisation of the ‘concatenated complex’ approach described herein. Experimental results using the orthogonal frequency division multiplexing (OFDM) and spectrally efficient frequency division multiplexing (SEFDM) modulation formats with varying bandwidth compression factors over a wireless visible light communication (VLC) link validate the efficacy of the proposed method in a real system, achieving the lowest error vector magnitude (EVM), and thus bit error rate (BER), across all experiments, with a 5 dB to 10 dB improvement in the received symbols EVM overall compared to the baseline implementation, with bandwidth compressions down to 40% compared to OFDM, resulting in a spectral efficiency gain of 67%.


2021 ◽  
Author(s):  
James Braun ◽  
Guillermo Paniagua ◽  
Donald Ferguson

Abstract Cycle benefits of rotating detonation engines show up to five percentage points of efficiency gain for low-pressure ratio engines. An optimal integration between the combustor and the turbine needs to be guaranteed to realize this potential gain. The rotating detonation combustor (RDC) exhausts transonic flow with shocks rotating at frequencies ranging from a few to tens of kilohertz depending on the number of present waves. Hence, the turbine design requires precise knowledge of the fluctuations and losses downstream of the combustor. This paper focuses on the quantification of fluctuations and losses for accelerating and diffusing passages. The analysis of the combustor is performed via reactive unsteady Reynolds Averaged Navier-Stokes (URANS) simulations. The unsteady RANS equations are solved via CFD++ from Metacomp with a one-step reaction mechanism for an H2-air mixture. The resolving of the boundary layer is achieved with a structured mesh of around 36 million cells. Inlet pressure of 10 bar and two different back pressures are applied to the combustor to model the interconnection with downstream turbines. Finally, we present and assess a methodology to reduce the computational time to model these passages ten times.


Sign in / Sign up

Export Citation Format

Share Document