A Novel Detection Method of Active and Reactive Currents in Single-Phase Circuits Using the Correlation and Cross-Correlation Coefficients and Its Applications

2007 ◽  
Vol 22 (4) ◽  
pp. 2450-2456 ◽  
Author(s):  
Toshihiko Tanaka ◽  
Eiji Hiraki ◽  
Kengo Ueda ◽  
Kuniaki Sato ◽  
Shinji Fukuma
2013 ◽  
Vol 35 (3) ◽  
Author(s):  
Tat Thang Nguyen ◽  
Hiroshige Kikura ◽  
Ngoc Hai Duong ◽  
Hideki Murakawa ◽  
Nobuyoshi Tsuzuki

Ultrasonic Velocity Profile (UVP) method for measurement of single-phase and two-phase flow in a vertical pipe has recently been developed in the Laboratory for industrial and Environmental Fluid Dynamics, Institute of Mechanics, VAST. The signal processings of the UVP method include the ultrasonic pulse Doppler method (UDM)and the ultrasonic time-domain cross-correlation (UTDC) method. For two-phase flow, simultaneous measurements of both liquid and gas are enabled by using a multi-wave ultrasonic transducer (multi-wave TDX). The multi-wave TDX is able to emit and receive ultrasound of two different center frequencies of 2 MHz and 8 MHz at the same time and position. 2 MHz frequency with beam diameter 10 mm is exploited for measurement of gas. 8 MHz one with beam diameter 3 mm is used for liquid. Measurements have been carried out for laminar and turbulent single-phase flows and bubbly counter-current two-phase flows in two flow loops using two vertical pipes of 26 mm inner diameter (I.D.) and 50 mm I.D. respectively. Based on the measured results, assessment of each method is clarified. Applicability of each method for different conditions of pipe flow has been tested. Suggestions for application of the two methods have been recommended.


Author(s):  
Matthias Weber ◽  
Anja Niehoff ◽  
Markus A. Rothschild

AbstractThis work deals with the examination of tool marks in human cartilage. We compared the effectiveness of several cleaning methods on cut marks in porcine cartilage. The method cleaning by multiple casts achieved the significantly highest scores (P = 0.02). Furthermore, we examined the grain-like elevations (dots) located on casts of cut cartilage. The results of this study suggest that the casting material forms these dots when penetrating cartilage cavities, which are areas where the strong collagen fibres leave space for the chondrocytes. We performed fixation experiments to avoid this, without success. In addition, 31 casting materials were compared regarding contrast under light-microscope and 3D tool marks scanner. Under the light-microscope, brown materials achieved significantly higher values than grey (P = 0.02) or black (P = 0.00) whereas under the 3D scanner, black materials reached higher contrast values than grey (P = 0.04) or brown (P = 0.047). To compare the accuracy and reproducibility of 6 test materials for cartilage, we used 10 knives to create cut marks that were subsequently scanned. During the alignment of the individual signals of each mark, the cross-correlation coefficients (Xmax) and lags (LXmax) were calculated. The signals of the marks in agarose were aligned with significantly fewer lags and achieved significantly higher cross-correlation coefficients compared to all tested materials (both P = 0.00). Moreover, we determined the cross-correlation coefficients (XC) for known-matches (KM) per material. Agarose achieved significantly higher values than AccuTrans®, Clear Ballistics™, and gelatine (all P = 0.00). The results of this work provide valuable insights for the forensic investigation of marks in human costal cartilage.


Author(s):  
Charles Deltour ◽  
Bart Dingenen ◽  
Filip Staes ◽  
Kevin Deschamps ◽  
Giovanni A. Matricali

Background: Foot–ankle motion is affected by chronic ankle instability (CAI) in terms of altered kinematics. This study focuses on multisegmental foot–ankle motion and joint coupling in barefoot and taped CAI patients during the three subphases of stance at running. Methods: Foot segmental motion data of 12 controls and 15 CAI participants during running with a heel strike pattern were collected through gait analysis. CAI participants performed running trials in three conditions: barefoot running, and running with high-dye and low-dye taping. Dependent variables were the range of motion (RoM) occurring at the different inter-segment angles as well as the cross-correlation coefficients between predetermined segments. Results: There were no significant RoM differences for barefoot running between CAI patients and controls. In taped conditions, the first two subphases only showed RoM changes at the midfoot without apparent RoM reduction compared to the barefoot CAI condition. In the last subphase there was limited RoM reduction at the mid- and rearfoot. Cross-correlation coefficients highlighted a tendency towards weaker joint coupling in the barefoot CAI condition compared to the controls. Joint coupling within the taped CAI conditions did not show optimization compared to the barefoot CAI condition. Conclusions: RoM was not significantly changed for barefoot running between CAI patients and controls. In taped conditions, there was no distinct tendency towards lower mean RoM values due to the mechanical restraints of taping. Joint coupling in CAI patients was not optimized by taping.


2017 ◽  
Vol 8 (4) ◽  
pp. 1821-1830 ◽  
Author(s):  
Qinfei Sun ◽  
Josep M. Guerrero ◽  
Tianjun Jing ◽  
Juan C. Vasquez ◽  
Rengang Yang

Sign in / Sign up

Export Citation Format

Share Document