A Novel Method for Selective Harmonic Elimination in Power Electronic Equipment

2007 ◽  
Vol 22 (1) ◽  
pp. 223-228 ◽  
Author(s):  
Vladimir Blasko

Recently the use of high power Voltage Source Inverter is increased but the problem of harmonic and switching losses in inverter are also increased because of the use of power electronic switches, which are used for fast and efficient operation. In this paper, for eliminating the harmonics presented in H Bridge inverter during switching operation of the power electronic switches the Selective Harmonic Elimination Pulse Width Modulation (SHEPWM) Technique is used. For H-Bridge operation specific switching angles are calculated by solving nonlinear equation using Newton Raphson method. The result of H-bridge single phase inverter are implemented on hardware with and without SHEPWM technique for eliminated specific 3 rd,5th,7th,9th,11th,13th voltage harmonics are obtained. Comparison of harmonic analysis of H bridge inverter with and without SHEPWM technique is done. In this paper Modulation index (m) is varied to control output voltage amplitude and the results are observed for maximum modulation index.


2019 ◽  
Vol 25 (3) ◽  
pp. 10-17
Author(s):  
Enes Bektas ◽  
Hulusi Karaca

In power electronic applications, especially high power and medium voltage, multilevel inverters (MLIs) have been commonly used. MLIs ensure high quality load voltage and lower Total Harmonic Distortion (THD) than traditional inverter. In this paper, a multilevel inverter structure with reduced number of power switches is proposed. The proposed multilevel inverter is lower costed than conventional MLI. Also, a Genetic Algorithm (GA) based Selective Harmonic Elimination (SHE) technique has been used for the first time in the proposed MLI structure with reduced number of switches. The proposed GA based SHE technique computes the optimum switching angles by solving nonlinear harmonic equations of multilevel inverter. Both Isochronous switching (IS) and SHE techniques have been applied to proposed MLI to demonstrate the effectiveness of the GA based SHE technique. Simulation and experimental results for 7, 11 and 13-level have been obtained. Results of 11-level inverter is analysed and given in detail. Results have clearly proved that desired order harmonics in proposed MLI topology can be eliminated by using GA based SHE technique and lower THD on the load voltage has been provided.


2021 ◽  
Author(s):  
Baharuddin Ismail ◽  
Muzamir Isa ◽  
M. Z. Aikhsan ◽  
M. N. K. H. Rohani ◽  
C. L. Wooi ◽  
...  

Author(s):  
Alla Eddine Toubal Maamar ◽  
M'hamed Helaimi ◽  
Rachid Taleb ◽  
Mostefa Kermadi ◽  
Saad Mekhilef

Sign in / Sign up

Export Citation Format