scholarly journals Estimating Optimal Parameters for MRF Stereo from a Single Image Pair

2007 ◽  
Vol 29 (2) ◽  
pp. 331-342 ◽  
Author(s):  
Li Zhang ◽  
Steven M. Seitz
2014 ◽  
Vol 31 (7) ◽  
pp. 1482-1501 ◽  
Author(s):  
Rusen Öktem ◽  
Prabhat ◽  
James Lee ◽  
Aaron Thomas ◽  
Paquita Zuidema ◽  
...  

This study extends ground-based stereophotogrammetry of clouds to oceanic settings, where there are often none of the landmarks used in traditional camera calibration. This paper introduces a zero-landmark calibration technique and tests it with two off-the-shelf digital cameras situated about 1 km apart facing Biscayne Bay in Miami, Florida. The precision of the stereo reconstruction is studied theoretically, and the accuracy of the reconstructions is validated against lidar and radiosondes. The stereo cameras are able to accurately reconstruct a histogram of cloud-base heights from a single-image pair, a task that requires tens of minutes of observation from a cloud lidar. The stereo cameras are also able to accurately reconstruct horizontal winds in cloud layers with a temporal resolution in the range of 30 s to 5 min, compared to once every 12 h for a typical radiosonde launch site.


2020 ◽  
Author(s):  
S. Benaim ◽  
R. Mokady ◽  
A. Bermano ◽  
L. Wolf

2013 ◽  
Vol 80 (10) ◽  
Author(s):  
Muhammad Atif ◽  
Bernd Jähne

AbstractWe present a computational imaging approach to estimate the depth from a single image using axial chromatic aberrations. It includes a co-design of optics and digital processing to select the optimal parameters of a lens such as focal length,


VASA ◽  
2015 ◽  
Vol 44 (2) ◽  
pp. 122-128 ◽  
Author(s):  
Mandy Becker ◽  
Tom Schilling ◽  
Olga von Beckerath ◽  
Knut Kröger

Background: To clarify the clinical use of sonography for differentiation of edema we tried to answer the question whether a group of doctors can differentiate lymphedema from cardiac, hepatic or venous edema just by analysing sonographic images of the edema. Patients and methods: 38 (70 ± 12 years, 22 (58 %) females) patients with lower limb edema were recruited according the clinical diagnosis: 10 (26 %) lymphedema, 16 (42 %) heart insufficiency, 6 (16 %) venous disorders, 6 (16 %) chronic hepatic disease. Edema was depicted sonographically at the most affected leg in a standardised way at distal and proximal calf. 38 sets of images were anonymised and send to 5 experienced doctors. They were asked whether they can see criteria for lymphedema: 1. anechoic gaps, 2. horizontal gaps and 3. echoic rims. Results: Accepting an edema as lymphedema if only one doctor sees at least one of the three criteria for lymphatic edema on each single image all edema would be classified as lymphatic. Accepting lymphedema only if all doctors see at least one of the three criteria on the distal image of the same patient 80 % of the patients supposed to have lymphedema are classified as such, but also the majority of cardiac, venous and hepatic edema. Accepting lymphedema only if all doctors see all three criteria on the distal image of the same patients no edema would be classified as lymphatic. In addition we separated patients by Stemmers’ sign in those with positive and negative sign. The interpretation of the images was not different between both groups. Conclusions: Our analysis shows that it is not possible to differentiate lymphedema from other lower limb edema sonographically.


The article is devoted to the actual problem of assigning optimal parameters for connecting steel plates on cover plates with angular welds that are widely used in construction practice. The article presents the results of a comprehensive study of operation of a welded assembly of the plates connection on cover plates. An algorithm is proposed for determining the optimal parameters of a welded joint with fillet welds on the cover plates, which makes it possible to obtain a strength balanced connection. The results of full-scale tensile tests of models were presented. These results confirmed the correctness of the assumed design assumptions, and made it possible to obtain a form of destruction, not characteristic and not described in the normative literature, expressed by cutting the main elements along the length of the overlap in the joint. The possibility of such a form of destruction was confirmed by the results of numerical research in a nonlinear formulation. The optimal parameters of the nodal welded joint determined by engineering calculation are confirmed by experimental studies, as well as by the results of numerical experiments on models of calculation schemes, taking into account the physical nonlinearity of the material operation. The obtained dependence for determining the bearing capacity of the joint by the cut-off mechanism and the expression for limiting the overlap length of the cover plates will make it possible to predict the nature of the fracture and design equally strong joints.


Author(s):  
Wenhua ZHANG ◽  
Shidong ZHANG ◽  
Yong WANG ◽  
Jianpeng WANG

2020 ◽  
Vol 2020 (1) ◽  
pp. 74-77
Author(s):  
Simone Bianco ◽  
Luigi Celona ◽  
Flavio Piccoli

In this work we propose a method for single image dehazing that exploits a physical model to recover the haze-free image by estimating the atmospheric scattering parameters. Cycle consistency is used to further improve the reconstruction quality of local structures and objects in the scene as well. Experimental results on four real and synthetic hazy image datasets show the effectiveness of the proposed method in terms of two commonly used full-reference image quality metrics.


Sign in / Sign up

Export Citation Format

Share Document