Image Deblurring Utilizing Inertial Sensors and a Short-Long-Short Exposure Strategy

2020 ◽  
Vol 29 ◽  
pp. 4614-4626
Author(s):  
Chenwei Yang ◽  
Huajun Feng ◽  
Zhihai Xu ◽  
Yueting Chen ◽  
Qi Li
2011 ◽  
Author(s):  
Yoshiyuki Tsuda ◽  
Haruo Hatanaka ◽  
Shimpei Fukumoto ◽  
Masaaki Ueda ◽  
Kunihiro Chihara

Author(s):  
Oleg Bostanjoglo ◽  
Peter Thomsen-Schmidt

Thin GexTe1-x (x = 0.15-0.8) were studied as a model substance of a composite semiconductor film, in addition being of interest for optical storage material. Two complementary modes of time-resolved TEM were used to trace the phase transitions, induced by an attached Q-switched (50 ns FWHM) and frequency doubled (532 nm) Nd:YAG laser. The laser radiation was focused onto the specimen within the TEM to a 20 μm spot (FWHM). Discrete intermediate states were visualized by short-exposure time doubleframe imaging /1,2/. The full history of a transformation was gained by tracking the electron image intensity with photomultiplier and storage oscilloscopes (space/time resolution 100 nm/3 ns) /3/. In order to avoid radiation damage by the probing electron beam to detector and specimen, the beam is pulsed in this continuous mode of time-resolved TEM,too.Short events ( <2 μs) are followed by illuminating with an extended single electron pulse (fig. 1c)


1993 ◽  
Vol 70 (04) ◽  
pp. 707-711 ◽  
Author(s):  
Andrew D Blann ◽  
Charles N McCollum

SummaryThe effect of smoking on the blood vessel intima was examined by comparing indices of endothelial activity in serum from smokers with that from non-smokers. Serum from smokers contained higher levels of von Willebrand factor (p <0.01), the smoking markers cotinine (p <0.02) and thiocyanate (p <0.01), and was more cytotoxic to endothelial cells in vitro (p <0.02) than serum from non-smokers. The acute effects of smoking two unfiltered medium tar cigarettes was to briefly increase von Willebrand factor (p <0.001) and cytotoxicity of serum to endothelial cells in vitro (p <0.005), but lipid peroxides or thiocyanate were not increased by this short exposure to tobacco smoke. Although there were correlations between von Willebrand factor and smokers consumption of cigarettes (r = 0.28, p <0.02), number of years smoking (r = 0.41, p <0.001) and cotinine (r = 0.45, p <0.01), the tissue culture of endothelial cells with physiological levels of thiocyanate or nicotine suggested that these two smoking markers were not cytotoxic. They are therefore unlikely to be directly responsible for increased von Willebrand factor in the serum of smokers. We suggest that smoking exerts a deleterious influence on the endothelium and that the mechanism is complex.


2020 ◽  
Vol 4 (2) ◽  
pp. 722-729
Author(s):  
Usman Sani ◽  
Bashir Gide Muhammad ◽  
Dimas Skam Joseph ◽  
D. Z. Joseph

Poor implementation of quality assurance programs in the radiation industry has been a major setback in our locality. Several studies revealed that occupational workers are exposed to many potential hazards of ionizing radiation during radio-diagnostic procedures, yet radiation workers are often not monitored. This study aims to evaluate the occupational exposure of the radiation workers in Federal Medical Centre Katsina, and to compare the exposure with recommended occupational radiation dose limits. The quarterly readings of 20 thermo-luminescent dosimeters (TLDs') used by the radiation workers from January to December, 2019 were collected from the facility's radiation monitoring archive, and subsequently assessed and analyzed. The results indicate that the average annual equivalent dose per occupational worker range from 0.74 to 1.20 mSv and 1.28 to 2.21 mSv for skin surface and deep skin dose, measured at 10 mm and 0.07 mm tissue depth respectively. The occupational dose was within the recommended national and international limits of 5 mSv per annum or an average of 20 mSv in 5 years. Therefore, there was no significant radiation exposure to all the occupational workers in the study area. Though, the occupational radiation dose is within recommended limit, this does not eliminate stochastic effect of radiation. The study recommended that the occupational workers should adhere and strictly comply with the principles of radiation protection which includes distance, short exposure time, shielding and proper monitoring of dose limits. Furthermore, continuous training of the radiation workers is advised.


2012 ◽  
Vol 43 (8) ◽  
pp. 749-765 ◽  
Author(s):  
Song He ◽  
Dongmei Huang ◽  
Zhengkun Qi ◽  
Hui Yang ◽  
Yin Hu ◽  
...  

2020 ◽  
Vol 2020 (17) ◽  
pp. 2-1-2-6
Author(s):  
Shih-Wei Sun ◽  
Ting-Chen Mou ◽  
Pao-Chi Chang

To improve the workout efficiency and to provide the body movement suggestions to users in a “smart gym” environment, we propose to use a depth camera for capturing a user’s body parts and mount multiple inertial sensors on the body parts of a user to generate deadlift behavior models generated by a recurrent neural network structure. The contribution of this paper is trifold: 1) The multimodal sensing signals obtained from multiple devices are fused for generating the deadlift behavior classifiers, 2) the recurrent neural network structure can analyze the information from the synchronized skeletal and inertial sensing data, and 3) a Vaplab dataset is generated for evaluating the deadlift behaviors recognizing capability in the proposed method.


Sign in / Sign up

Export Citation Format

Share Document