Digital Count-Rate Meter and Flux-Change-Rate Meter with Automatic Adjust of Counting Time Based on FPGA for Pulse-Mode Flux Measurements in Nuclear Reactors

Author(s):  
Gloria Rios ◽  
Daniel S. Estryk ◽  
Claudio A. Verrastro
Author(s):  
Hang Li ◽  
Hongseok Choi ◽  
Chao Ma ◽  
Jingzhou Zhao ◽  
Hongrui Jiang ◽  
...  

Process physics understanding, real time monitoring, and control of various manufacturing processes, such as battery manufacturing, are crucial for product quality assurance. While ultrasonic welding has been used for joining batteries in electric vehicles (EVs), the welding physics, and process attributes, such as the heat generation and heat flow during the joining process, is still not well understood leading to time-consuming trial-and-error based process optimization. This study is to investigate thermal phenomena (i.e., transient temperature and heat flux) by using micro thin-film thermocouples (TFTC) and thin-film thermopile (TFTP) arrays (referred to as microsensors in this paper) at the very vicinity of the ultrasonic welding spot during joining of three-layered battery tabs and Cu buss bars (i.e., battery interconnect) as in General Motors's (GM) Chevy Volt. Microsensors were first fabricated on the buss bars. A series of experiments were then conducted to investigate the dynamic heat generation during the welding process. Experimental results showed that TFTCs enabled the sensing of transient temperatures with much higher spatial and temporal resolutions than conventional thermocouples. It was further found that the TFTPs were more sensitive to the transient heat generation process during welding than TFTCs. More significantly, the heat flux change rate was found to be able to provide better insight for the process. It provided evidence indicating that the ultrasonic welding process involves three distinct stages, i.e., friction heating, plastic work, and diffusion bonding stages. The heat flux change rate thus has significant potential to identify the in-situ welding quality, in the context of welding process monitoring, and control of ultrasonic welding process. The weld samples were examined using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) to study the material interactions at the bonding interface as a function of weld time and have successfully validated the proposed three-stage welding theory.


1988 ◽  
Vol 255 (5) ◽  
pp. G696-G699
Author(s):  
R. W. Egnor ◽  
S. G. Vaccarezza ◽  
A. N. Charney

We examined several sources of error in isotopic flux measurements in a commonly used experimental model: the study of 22Na and 36Cl fluxes across rat ileal tissue mounted in the Ussing flux chamber. The experiment revealed three important sources of error: the absolute counts per minute, the difference in counts per minute between serial samples, and averaging of serial samples. By computer manipulation, we then applied hypothetical changes in the experimental protocol to generalize these findings and assess the effect and interaction of the absolute counts per minute, the sampling interval, and the counting time on the magnitude of the error. We found that the error of a flux measurement will vary inversely with the counting time and the difference between the consecutive sample counts per minute used in the flux calculations and will vary directly with the absolute counts per minute of each sample. Alteration of the "hot" side specific activity, the surface area of the tissue across which flux is measured and the sample volume have a smaller impact on measurement error. Experimental protocols should be designed with these methodological considerations in mind to minimize the error inherent in measuring isotope flux.


Author(s):  
Delbert E. Philpott ◽  
David Leaffer

There are certain advantages for electron probe analysis if the sample can be tilted directly towards the detector. The count rate is higher, it optimizes the geometry since only one angle need be taken into account for quantitative analysis and the signal to background ratio is improved. The need for less tilt angle may be an advantage because the grid bars are not moved quite as close to each other, leaving a little more open area for observation. Our present detector (EDAX) and microscope (Philips 300) combination precludes moving the detector behind the microscope where it would point directly at the grid. Therefore, the angle of the specimen was changed in order to optimize the geometry between the specimen and the detector.


1981 ◽  
Vol 20 (06) ◽  
pp. 274-278
Author(s):  
J. Liniecki ◽  
J. Bialobrzeski ◽  
Ewa Mlodkowska ◽  
M. J. Surma

A concept of a kidney uptake coefficient (UC) of 131I-o-hippurate was developed by analogy from the corresponding kidney clearance of blood plasma in the early period after injection of the hippurate. The UC for each kidney was defined as the count-rate over its ROI at a time shorter than the peak in the renoscintigraphic curve divided by the integral of the count-rate curve over the "blood"-ROI. A procedure for normalization of both curves against each other was also developed. The total kidney clearance of the hippurate was determined from the function of plasma activity concentration vs. time after a single injection; the determinations were made at 5, 10, 15, 20, 30, 45, 60, 75 and 90 min after intravenous administration of 131I-o-hippurate and the best-fit curve was obtained by means of the least-square method. When the UC was related to the absolute value of the clearance a positive linear correlation was found (r = 0.922, ρ > 0.99). Using this regression equation the clearance could be estimated in reverse from the uptake coefficient calculated solely on the basis of the renoscintigraphic curves without blood sampling. The errors of the estimate are compatible with the requirement of a fast appraisal of renal function for purposes of clinical diagknosis.