Wide-band real-time frequency measurement using compressive receiver

Author(s):  
P. Keerthan ◽  
Ritesh Kumar ◽  
K. J. Vinoy
2021 ◽  
Vol 18 (3) ◽  
pp. 271-289
Author(s):  
Evgeniia Bulycheva ◽  
Sergey Yanchenko

Harmonic contributions of utility and customer may feature significant variations due to network switchings and changing operational modes. In order to correctly define the impacts on the grid voltage distortion the frequency dependent impedance characteristic of the studied network should be accurately measured in the real-time mode. This condition can be fulfilled by designing a stimuli generator measuring the grid impedance as a response to injected interference and producing time-frequency plots of harmonic contributions during considered time interval. In this paper a prototype of a stimuli generator based on programmable voltage source inverter is developed and tested. The use of ternary pulse sequence allows fast wide-band impedance measurements that meet the requirements of real-time assessment of harmonic contributions. The accuracy of respective analysis involving impedance determination and calculation of harmonic contributions is validated experimentally using reference characteristics of laboratory test set-up with varying grid impedance.


Open Physics ◽  
2021 ◽  
Vol 19 (1) ◽  
pp. 434-438
Author(s):  
Xin Geng ◽  
Baoqiang Du ◽  
Jianwei Zhang ◽  
Erlin Tian

Abstract In order to achieve wide-band high-resolution frequency measurement, a frequency synchronization detection method based on adaptive frequency standard tracking is proposed based on the quantized phase processing. First, the nominal value of the measured frequency signal was obtained from the rough frequency measurement module. Then, the field programmable gate array generated the nominal value of the measured frequency. After that, the direct comparison between the tracking frequency and the measured signal was carried out. Finally, the group quantized processing module gave the final result according to the phase full-period change time. Experimental results showed that the method has a wide frequency measurement range and high accuracy and can obtain frequency stability of the order of 10−13/s.


2013 ◽  
Vol 333-335 ◽  
pp. 650-655
Author(s):  
Peng Hui Niu ◽  
Yin Lei Qin ◽  
Shun Ping Qu ◽  
Yang Lou

A new signal processing method for phase difference estimation was proposed based on time-varying signal model, whose frequency, amplitude and phase are time-varying. And then be applied Coriolis mass flowmeter signal. First, a bandpass filtering FIR filter was applied to filter the sensor output signal in order to improve SNR. Then, the signal frequency could be calculated based on short-time frequency estimation. Finally, by short window intercepting, the DTFT algorithm with negative frequency contribution was introduced to calculate the real-time phase difference between two enhanced signals. With the frequency and the phase difference obtained, the time interval of two signals was calculated. Simulation results show that the algorithms studied are efficient. Furthermore, the computation of algorithms studied is simple so that it can be applied to real-time signal processing for Coriolis mass flowmeter.


2013 ◽  
Vol 93 (5) ◽  
pp. 1392-1397 ◽  
Author(s):  
Ljubiša Stanković ◽  
Miloš Daković ◽  
Thayananthan Thayaparan

2003 ◽  
Vol 1 (2) ◽  
pp. 175-177
Author(s):  
Mitsuaki YAMAMOTO ◽  
Norihiro KATAYAMA ◽  
Mitsuyuki NAKAO ◽  
Ryo KITAHARA ◽  
Takashi UENO ◽  
...  

Author(s):  
M. Tykesson ◽  
L. Sabel ◽  
R. Wozniak ◽  
T. Zierch ◽  
D. Tran ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document