A novel flux-based protection scheme for power transformers

Author(s):  
Farhad Haghjoo ◽  
Mohsen Mostafaei ◽  
Mohsen Mohammadzadeh
2015 ◽  
Vol 16 (4) ◽  
pp. 339-348 ◽  
Author(s):  
Ashesh Mukeshbhai Shah ◽  
Bhavesh Bhalja

Abstract This paper presents a new adaptive differential protection scheme which efficiently adapts the change in tap position of a power transformer. The proposed scheme is based on analytical derivation of pick-up and slope of the differential relay characteristic. By acquiring information such as rating & connection of CTs and present tap position as input, the proposed scheme enhances sensitivity of differential relay during internal faults. This is accomplished either by decreasing pick-up and/or adjusting slope of the differential characteristic of the relay in case of change in tap position. Numerous test cases consisting of various types of internal and external faults have been simulated for an existing power transformer of Gujarat Energy Transmission Corporation Limited (GETCO), Gujarat, India using PSCAD/EMTDC software package. The proposed scheme increases percentage of winding to be protected during internal faults for power transformers having different ratings and connections compared to the conventional differential protection scheme. Furthermore, it has been observed that the detection sensitivity during special types of turn-to-turn and inter-winding faults with varying fault resistances is also enhanced compared to the conventional scheme. Moreover, it equally maintains stability during CT saturation condition. At the end, comparative evaluation of the proposed scheme with the existing schemes clearly indicates superiority of the proposed adaptive scheme.


2008 ◽  
Vol 71 (4-6) ◽  
pp. 904-918 ◽  
Author(s):  
M. Geethanjali ◽  
S. Mary Raja Slochanal ◽  
R. Bhavani

2020 ◽  
Vol 6 (4) ◽  
Author(s):  
Martin Brůha ◽  
Tore Nilsen

Variable Speed Drives (VSD) protect themselves as well as the driven motors. In contrast, the isolation input transformer typically requires its dedicated protection. Unlike distribution and power transformers, the protection of VSD duty transformers need to consider several additional aspects, such as non-sinusoidal current with harmonic content, multi-winding design, phase-shifted converter windings etc. This paper aims to explain the challenges related to protection of VSD transformers. A guideline for reliable transformer protection based on good design practice is proposed. Finally the possibility to integrate the transformer protection into the VSD protection scheme is being explored.


2020 ◽  
Vol 87 ◽  
pp. 105975 ◽  
Author(s):  
Shahabodin Afrasiabi ◽  
Mousa Afrasiabi ◽  
Benyamin Parang ◽  
Mohammad Mohammadi

2019 ◽  
Vol 13 (12) ◽  
pp. 2423-2437 ◽  
Author(s):  
Arpita Roy ◽  
Devender Singh ◽  
Rakesh Kumar Misra ◽  
Amit Singh