Impact of Distributed Generation on voltage profile and power losses in a test power grid

Author(s):  
Ionel Lepadat ◽  
Elena Helerea ◽  
Sorin Abagiu ◽  
Catalin Mihai
2019 ◽  
Vol 8 (3) ◽  
pp. 978-984
Author(s):  
Nur Ainna Shakinah Abas ◽  
Ismail Musirin ◽  
Shahrizal Jelani ◽  
Mohd Helmi Mansor ◽  
Naeem M. S. Honnoon ◽  
...  

This paper presents the optimal multiple distributed generations (MDGs) installation for improving the voltage profile and minimizing power losses of distribution system using the integrated monte-carlo evolutionary programming (EP). EP was used as the optimization technique while monte carlo simulation is used to find the random number of locations of MDGs. This involved the testing of the proposed technique on IEEE 69-bus distribution test system. It is found that the proposed approach successfully solved the MDGs installation problem by reducing the power losses and improving the minimum voltage of the distribution system.


Author(s):  
Su Hlaing Win ◽  
Pyone Lai Swe

A Radial Distribution network is important in power system area because of its simple design and reduced cost. Reduction of system losses and improvement of voltage profile is one of the key aspects in power system operation. Distributed generators are beneficial in reducing losses effectively in distribution systems as compared to other methods of loss reduction. Sizing and location of DG sources places an important role in reducing losses in distribution network. Four types of DG are considered in this paper with one DG installed for minimize the total real and reactive power losses. The objective of this methodology is to calculate size and to identify the corresponding optimum location for DG placement for minimizing the total real and reactive power losses and to improve voltage profile   in primary distribution system. It can obtain maximum loss reduction for each of four types of optimally placed DGs. Optimal sizing of Distributed Generation can be calculated using exact loss formula and an efficient approach is used to determine the optimum location for Distributed Generation Placement.  To demonstrate the performance of the proposed approach 36-bus radial distribution system in Belin Substation in Myanmar was tested and validated with different sizes and the result was discussed.


Author(s):  
N. Md. Saad ◽  
M. Z. Sujod ◽  
Lee Hui Ming ◽  
M. F. Abas ◽  
M. S. Jadin ◽  
...  

As the rapid development of photovoltaic (PV) technology in recent years with the growth of electricity demand, integration of photovoltaic distributed generation (PVDG) to the distribution system is emerging to fulfil the demand. There are benefits and drawbacks to the distribution system due to the penetration of PVDG. This paper discussed and investigated the impacts of PVDG location and size on distribution power systems. The medium voltage distribution network is connected to the grid with the load being supplied by PVDG. Load flow and short circuit calculation are analyzed by using DigSILENT Power Factory Software. Comparisons have been made between the typical distribution system and the distribution system with the penetration of PVDG. Impacts in which PVDG location and size integrates with distribution system are investigated with the results given from the load flow and short circuit analysis. The results indicate positive impacts on the system interconnected with PVDG such as improving voltage profile, reducing power losses, releasing transmission and distribution grid capacity. It also shows that optimal locations and sizes of DGs are needed to minimize the system’s power losses. On the other hand, it shows that PVDG interconnection to the system can cause reverse power flow at improper DG size and location and increases short circuit level.


2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Sanjay Jain ◽  
Ganga Agnihotri ◽  
Shilpa Kalambe ◽  
Renuka Kamdar

This paper intends to enumerate the impact of distributed generation (DG) on distribution system in terms of active as well as reactive power loss reduction and improved voltage stability. The novelty of the method proposed in this paper is the simple and effective way of sizing and siting of DG in a distribution system by using two-port Z-bus parameters. The validity of the method is verified by comparing the results with already published methods. Comparative study presented has shown that the proposed method leads existing methods in terms of its simplicity, undemanding calculation procedures, and less computational efforts and so does the time. The method is implemented on IEEE 69-bus test radial distribution system and results show significant reduction in distribution power losses with improved voltage profile of the system. Simulation is carried out in MATLAB environment for execution of the proposed algorithm.


Author(s):  
Manoj Kumar Nigam ◽  
V.K. Sethi

<p>Distributed generation (DG) technology is based on the renewable sources of energy. Now a day’s distributed generation plays an important role of power generation utilities to fulfill the increasing demand of power at the costumer’s site. A distributed generation is the small generation unit with capacity varying from kW (kilowatt) to few MW (megawatt). The main aim of this paper is to find the solution for optimal location of connecting DG and also the disturbances in the voltage fluctuations responds to imperfection of connecting DG. A test network of IEEE-30 bus system has been simulated using PSAT 2.1.7. The compensation methods have also been developed for filtering out the disturbances caused by the DG connection. The disturbance in the voltage profile is improved by minimizing the real and reactive power losses with the help of STATCOM. The proposed approach IEEE-30-bus system was tested and the result was discussed.</p>


2021 ◽  
Vol 56 (2) ◽  
pp. 542-551
Author(s):  
Ardiaty Arief ◽  
Muhammad Bachtiar Nappu ◽  
Ian Thomas

The power grid in the capital city of Papua New Guinea, Port Moresby, still experiences problems of voltage stability and power losses due to many factors which is the common problem that most power systems continue to mitigate until today. The factors that give rise to these problems are the imbalance between generation and load and the long-distance of transmission lines. A possible solution to counteract these problems is to integrate photovoltaic systems into the power grid, especially at the load distribution network. This paper presents PV placement for Port Moresby system by using two stages, which are (1) identification of location with good irradiance then (2) determination of PV location by minimizing power losses and improving the voltage profile. This alternative approach is considered because Port Moresby city is situated in a location that is exposed to a significant amount of solar radiation of about 1976 kWh/m2 GHI annually. Therefore, this makes Port Moresby a suitable location to utilize this type of renewable energy technology. This research provides an analysis of the power flow within the Port Moresby grid through simulation using the Newton-Raphson method. The analysis and simulations are performed to identify the most sensitive buses within the system. Based on their high irradiance levels, these specific areas are identified as the best possible areas for integrating the photovoltaic system.


2019 ◽  
Vol 4 (10) ◽  
pp. 18-23 ◽  
Author(s):  
Abubakar Bawa ◽  
Muhammad Uthman ◽  
Farouq E. Shaibu ◽  
Koledowo Saliu Oyewale

The Point of Common Coupling (PCC) where suppliers’ responsibility and customers demand meet is of great concern due to increase degree of voltage variation assessment; valuable indicator of system conditions (voltage profile). Unstable condition of the power system outside operational or statutory limit, an adverse effect of nonlinear loads usually generate harmonics as well as fundamental frequency voltage variations and increase rate of power losses. These loads need to be compensated for. The major concerns of utility operations is to mitigate adverse effect of this system conditions. This research work focuses on optimal siting and sizing of Distributed Generation (DG) in a 43 bus distribution system. Power losses coupled with voltage deviation, considering objective function that compute present percentage losses in 11kV Dikko feeder, Abuja Electricity Distribution Company (AEDC), Suleja Distribution Network, Nigeria. We identified buses with poor voltage profile without DG installation and determined optimal sizing and siting of DGs where losses can be mitigated and power quality improved. ETAP version 12.6 2014 was used for load flow analysis to establish a decisive based case. The total load of the system considered was (3490 + j2700) kVA. Active and Reactive power losses in the system before DG installation were 246.300 kW and 289.903 kVAR respectively. DGs installation in the case study, has a considerable effects on loss reduction in the network. It is observed that 8.10% and 7.20% active and reactive power loss reduction was achieved while bus voltage improved by 0.4%. Genetic Algorithm Optimization techniques programmed in MATLAB 2015 software was used for optimal placement and sizing of the DG in the system.


2019 ◽  
Vol 4 (4) ◽  
pp. 83-89 ◽  
Author(s):  
Evans Chinemezu Ashigwuike ◽  
Stephen Adole Benson

The growing gap between electric power generated and that demanded is of utmost concern especially in developing economy, hence calling for measures to argument the existing power generated of which DG is a more viable aspect to explore in curtailing this challenges; although been confronted with issue of location and sizing. This research applied Adaptive neuro fuzzy logic technique to optimize DG location and size. A 24 bus radial network was used to demonstrate this process and having a suitable location and size at optimal position reduces power losses and also improves the voltage profile at the buses. The method was simulated using ANFIS toolbox MATLAB R2013b (8.2.0.701) 64-bit software and tested using Gwagwalada injection sub-station feeder 1 system. The results obtained were compared to that obtained using ANN. It was observed that adaptive neuro fuzzy logic technique performed better in terms of reducing power losses compared to ANN technique. The percentage reduction in the power loss at the buses cumulatively is 48.96% for ANN while adaptive neuro fuzzy logic technique is 49.21%. The voltage profile of the networks after optimizing the DG location and sizes using adaptive neuro fuzzy logic technique were also found to be much improved with the lowest bus voltage improved from 0.9284 to 1.05pu.


Distributed generation system penetration in the existing distribution system is done for minimizing the losses and improving the voltage profile. There are total five types of distributed generation systems exist based on their power delivery like distributed generation system injecting real and reactive power, supplying real power only, supplying reactive power only, absorbing reactive power only , supplying real power and absorbing reactive power. All these five types of distributed generation systems have different penetration effects on the radial distribution system. We get different voltage profiles and power losses for different types of distributed generation systems. The testing of these five types of distributed generation systems will be done on IEEE 33 bus radial distribution system. For computing, the line parameters and power losses of the above testing system the forward-backward sweep load flow method will be applied


2021 ◽  
Vol 309 ◽  
pp. 01071
Author(s):  
R. Kavyasree ◽  
J. Sridevi ◽  
V. Usha Rani

Nowadays, in the Evolving Power System, reliability testing plays an important role in the design and implementation of distribution systems that operate in a cost-effective manner with minimal customer load disruption. The distributed generation (DG) will play a major role in emerging Power systems as they use a variety of resources and technologies to harness energy in Power systems by reducing Power losses while maintaining the Voltage profile in the system within the limits set. In this paper, two case studies with one DG and two DGs were analysed. The results obtained showed that the DG Number with the plan will increase the reliability of the joint system. The proven system is verified before the IEEE 6-Bus Radial Distributed System to reflect exposure and impact on ETAP software.


Sign in / Sign up

Export Citation Format

Share Document