On Automatic Flying Distance Measurement on Ski Jumper's Motion Monitoring System

Author(s):  
Nobuyoshi Sato ◽  
Tsuyoshi Takayama ◽  
Yoshitoshi Murata
2014 ◽  
Vol 14 (2) ◽  
pp. 100
Author(s):  
Satoro Disney Karwur ◽  
Hesky S. Kolibu ◽  
Verna A. Suoth

ABSTRACT A research has been conducted to make an object detector prototype using ultrasonic sensor for indoor security monitoring system. The testing object placed in front of the sensor and the measurement conducted in distance and angle variations. For indoor implementation, graphical display of object detection on computer screen given by blue-to-yellow transition to indicate the nearing object and its reverse to indicate the fading object. The trend of accuracy of the object distance measurement has a declining linear pattern, it means that the accuracy of object detection will decrease if the distance and or angle from the object to the detector are increase. Keywords: object detector, ultrasonic sensor,  indoor security monitoring   PURWARUPA DETEKTOR OBJEK MENGGUNAKAN SENSOR ULTRASONIK UNTUK SISTEM PEMANTAUAN KEAMANAN DALAM RUANGAN ABSTRAK Sebuah penelitian telah dilakukan untuk membuat purwarupa detektor objek menggunakan sensor ultrasonik untuk sistem pemantauan keamanan dalam ruangan. Objek pengujian diletakkan di depan sensor dan pengukuran dilakukan pada variasi jarak dan sudut.  Untuk implementasi dalam ruangan, tampilan grafis pendeteksian objek pada layar komputer diberikan oleh transisi warna biru ke kuning untuk menunjukkan objek yang mendekat dan kebalikannya untuk menunjukkan objek yang menjauh. Tren akurasi pendeteksian objek memiliki pola menurun secara linear, itu berarti bahwa akurasi pendeteksian objek akan berkurang jika jarak dan atau sudut dari objek ke detektor bertambah besar. Kata kunci: detektor objek, sensor ultrasonik, pemantauan keamanan dalam ruangan


2018 ◽  
Vol 9 (1) ◽  
pp. 16-23
Author(s):  
Ansor Usman ◽  
Hendra Marwazi ◽  
Samsul Alam

Modeling tool is made an attempt to help health care in special hospitals for care in obstetrics and perinatology space. This study used temperature setting range is from 34 ° C to 38 ° C, while for setting the humidity of the range of 0% to 100%, is divided into two parts, namely the design of hardware and software. Tests conducted in the Laboratory of the Department of Health Polytechnic Elektromedik Jakarta II. Design manufacture of modules that do get into the telemetry monitoring system applications, where telemetry tool can be used to monitor the value of an object located at a remote distance applied to medical devices, which will be monitored temperature and humidity is a very important part in the incubator tool baby. The results of modeling design includes testing of skin temperature in the incubator, the test measurement of skin temperature and humidity in the telemetry receiver, test measurement of skin temperature on the thermometer, hygrometer humidity in the test measurement. With the results of the five test measurement was still below the threshold of 10%. It can be concluded that the telemetry tool can perform accurate distance measurement, in accordance with the amount of heat generated by the source and the humidity is a tool incubator. This research can be developed to monitor the temperature and humidity with computer based.


Author(s):  
Susanne Roesner ◽  
Heinrich Küfner
Keyword(s):  

<span class="fett">Hintergrund und Zielsetzung:</span> PHAR-MON ist ein Monitoring-System, das die auf dem deutschen Markt befindlichen Arzneimittel in ihrer Bedeutung für die Entwicklung von Missbrauch und Abhängigkeit in Suchtberatungsstellen überwacht. </p><p> <span class="fett">Methodik:</span> Klienten ambulanter Beratungsstellen werden im Rahmen der Standarddokumentation zu ihrem Arzneimittelkonsum befragt und Fälle eines abhängigen Konsums, eines schädlichen Gebrauchs oder eines Missbrauchs in PHAR-MON dokumentiert. </p><p> <span class="fett">Ergebnisse:</span> Im Jahr 2006 wurden insgesamt 448 Meldungen von 276 überwiegend alkohol- und drogenabhängigen Klienten in das Monitoring einbezogen. Tranquilizer vom Benzodiazepin-Typ wurden in allen Klientengruppen mit Anteilen zwischen 29,1 % und 35,3 % am häufigsten dokumentiert. An benzodiazepinabhängige Klienten werden zunehmend auch Nicht-Benzodiazepin-Hypnotika verordnet. Bei opioidabhängigen Klienten war im Zeitraum der letzten fünf Jahre ein Anstieg im missbräuchlichen Substitutionsmittelkonsum von 14,9 % auf 33,8 % zu verzeichnen. </p><p> <span class="fett">Schlussfolgerungen:</span> Das Risiko gefährlicher Wechselwirkungen zwischen Arzneimitteln mit Alkohol und Drogen sollte stärker als bisher in die ärztliche Verordnungsentscheidung einbezogen werden.


2012 ◽  
Author(s):  
Yiyun Peng ◽  
Mahtab Ghazizadeh ◽  
Linda Ng Boyle ◽  
John D. Lee

Sign in / Sign up

Export Citation Format

Share Document