New Solid-State on-Load Tap-Changer Topology for Distribution Transformers

2002 ◽  
Vol 22 (8) ◽  
pp. 71-71 ◽  
Author(s):  
J. Faiz ◽  
B. Siahkolah
Vestnik MEI ◽  
2020 ◽  
Vol 6 (6) ◽  
pp. 82-90
Author(s):  
Dmitriy I. Panfilov ◽  
◽  
Mikhail G. Astashev ◽  
Aleksandr V. Gorchakov ◽  
◽  
...  

The specific features relating to voltage control of power transformers at distribution network transformer substations are considered. An approach to implementing high-speed on-load voltage control of serially produced 10/0.4 kV power transformers by using a solid-state on-load tap changer (SOLTC) is presented. An example of the SOLTC circuit solution on the basis of thyristor switches is given. On-load voltage control algorithms for power transformers equipped with SOLTC that ensure high reliability and high-speed operation are proposed. The SOLTC performance and the operability of the suggested voltage control algorithms were studied by simulation in the Matlab/Simulink environment and by experiments on the SOLTC physical model. The structure and peculiarities of the used simulation Matlab model are described. The SOLTC physical model design and its parameters are presented. The results obtained from the simulating the SOLTC operation on the Matlab model and from the experiments on the SOLTS physical model jointly with a power transformer under different loads and with using different control algorithms are given. An analysis of the experimental study results has shown the soundness of the adopted technical solutions. It has been demonstrated that the use of an SOLTC ensures high-speed voltage control, high efficiency and reliability of its operation, and arcless switching of the power transformer regulating taps without load voltage and current interruption. By using the SOLTC operation algorithms it is possible to perform individual phase voltage regulation in a three-phase 0.4 kV distribution network. The possibility of integrating SOLTC control and diagnostic facilities into the structure of modern digital substations based on the digital interface according to the IEC 61850 standard is noted.


Energies ◽  
2020 ◽  
Vol 13 (8) ◽  
pp. 1996
Author(s):  
Rong-Ceng Leou ◽  
Jen-Hao Teng ◽  
Yun-Fang Li ◽  
Wei-Min Lin ◽  
Yu-Hung Lin

This paper studies the system unbalance caused by rooftop Photovoltaic Generation Systems (PVGSs) in distribution networks and proposes an improved method. The voltage and current unbalance studies for three extreme cases considering all rooftop PVGSs being connected to one single phase and then the stochastic analyses for the integration cases of rooftop PVGSs are considered. These three extreme cases lead to severe system unbalance problems. An improving method that combines the On Load Tap Changer (OLTC) and the optimal phase arrangement of distribution transformers is proposed in this paper to mitigate the system unbalance. The OLTC-based improving method is applied first. If the system unbalance is still out of range, the optimal phase arrangement of distribution transformers is further used to mitigate the system unbalance problem. The objective function of optimal phase arrangement is to minimize the system unbalance with the constraints of voltage limits, line flow limit, etc. Test results show that the proposed method can improve the system unbalance significantly even under very extreme cases.


Sign in / Sign up

Export Citation Format

Share Document