Design and testing of a novel, low-cost, low-voltage, functional electrical stimulator

Author(s):  
Ashley M. Stewart ◽  
Christopher G. Pretty ◽  
XiaoQi Chen
2008 ◽  
Vol 55 ◽  
pp. 150-153
Author(s):  
Mun Ja Kim ◽  
Sung Min Park ◽  
Tae Young Lee ◽  
Sang Hyun Park ◽  
Jin Young Kim ◽  
...  

For the growth of Electroluminescent (EL) device market, the attention of many researchers is centered on improving the properties such as brightness, power consumption, device reliability, etc. The powder EL device is one of solutions for the easy mass production, the simplification of structure, and low cost. Although the powder process is the solution, that has the problem with the poor brightness than the film process. So, we focused on increasing the brightness of powder EL device. The emissive layer was made up the composites adding metal oxide nanopowder such as TiO2 and ZnO to powder phosphors. As the data of previous researcher, the TiO2 and ZnO had the different dominating traps by photovoltage measure, that is, TiO2 show hole traps, ZnO show electron traps [1]. The brightness of powder EL device proportions to the high electricfield formation. The TiO2 or ZnO in the powder phosphor composite can help the emission that may be advantageous to form high electricfield at low voltage. The EL devices with green ZnS phosphor were fabricated using spin coating method. The effect of TiO2 and ZnO on the luminescent property of EL device was investigated. The brightness was obtained as applied driving voltage at 400 Hz and frequency variation at 50 V.


Author(s):  
Olalekan Kabiru Kareem ◽  
Aderibigbe Adekitan ◽  
Ayokunle Awelewa

Electric power is the bedrock of our modern way of life. In Nigeria, power supply availability, sufficiency and reliability are major operational challenges. At the generation and transmission level, effort is made to ensure status monitoring and fault detection on the power network, but at the distribution level, particularly within domestic consumer communities there are no fault monitoring and detection devices except for HRC fuses at the feeder pillar. Unfortunately, these fuses are sometimes replaced by a copper wire bridge at some locations rendering the system unprotected and creating a great potential for transformer destruction on overload. This study is focused on designing an on-site power system monitoring device to be deployed on selected household entry power cables for detecting and indicating when phase off, low voltage, high voltage, over current, and blown fuse occurs on the building’s incomer line. The fault indication will help in reducing troubleshooting time and also ensure quick service restoration. After design implementation, the test result confirms design accuracy, device functionality and suitability as a low-cost solution to power supply system fault monitoring within local communities.


Author(s):  
Mohd Ahamad

A new concept in power generation is a microgrid. The Microgrid concept assumes a cluster of loads and microsources operating as a single controllable system that provides power to its local area. This concept provides a new paradigm for defining the operation of distributed generation. The microsources of special interest for MGs are small (<100-kW) units with power electronic interfaces. These sources are placed at customers sites. They are low cost, low voltage and have a high reliability with few emissions. Power electronics provide the control and flexibility required by the MG concept. A properly designed power electronics and controllers insure that the MG can meet the needs of its customers as well as the utilities. The goal of this project is to build a complete model of Microgrid including the power sources, their power electronics, and a load and mains model in THE HOMER. The HOMER Micropower Optimization Model is a computer model developed by the U.S. National Renewable Energy Laboratory (NREL) to assist in the design of micropower systems and to facilitate the comparison of power generation technologies across a wide range of applications. HOMER models a power system’s physical behavior and its life-cycle cost, which is the total cost of installing and operating the system over its life span. HOMER allows the modeler to compare many different design options based on their technical and economic merits. It also assists in understanding and quantifying the effects of uncertainty or changes in the inputs.


Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6361
Author(s):  
Giovanni Artale ◽  
Giuseppe Caravello ◽  
Antonio Cataliotti ◽  
Valentina Cosentino ◽  
Dario Di Cara ◽  
...  

This paper presents a feasibility study on how to implement power quality (PQ) metrics in a low-cost smart metering platform. The study is aimed at verifying the possibility of implementing PQ monitoring in distribution networks without replacing existing smart metering devices or adding new modules for PQ measurements, thus zeroing the installation costs. To this aim, an electronic board, currently used for remote energy metering, was chosen as a case study, specifically the STCOMET platform. Starting from the specifications of this device, the possibility of implementing power quality metrics is investigated in order to verify if compliance with standard requirements for PQ instruments can be obtained. Issues related to device features constraints are discussed; possible solutions and correction algorithms are presented and experimentally verified for different PQ metrics with a particular focus on harmonic analysis. The feasibility study takes into account both the use of on-board voltage and current transducers for low voltage applications and also the impact of external instrument transformers on measurement results.


2011 ◽  
Vol 128-129 ◽  
pp. 686-689 ◽  
Author(s):  
Dan Ping Jia ◽  
Yang Wang ◽  
Song Lin ◽  
Quan Kang Wei

Thin film sensor has the advantages of small size and low cost, which has become a research hotspot in recent years. A measurement system of passive optical fiber DC current sensor based on the thin film sensors is designed in this article. Designs of electric-heating converter, heating-light converter and low-voltage measurement display system are introduced in detail. Experimental results indicate that the general linear correlation between the time constant of fluorescent lifetime and the voltage across the thin film resistor. The feasibility of measurement system is verified via the results of the experiment.


Author(s):  
K. Ramkumar ◽  
I. Kouznetsov ◽  
V. Prabhakar ◽  
K. Shakeri ◽  
X. Yu ◽  
...  
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document