Reproducibility analysis of a TDR-based monitoring system for intravenous drip infusions: Validation of a novel method for flow-rate measurement in IV infusion

Author(s):  
Andrea Cataldo ◽  
Giuseppe Cannazza ◽  
Egidio De Benedetto ◽  
Nicola Giaquinto ◽  
Amerigo Trotta
2014 ◽  
Vol 136 (3) ◽  
Author(s):  
Nigel Johnston ◽  
Min Pan ◽  
Sylwester Kudzma ◽  
Pengfei Wang

A novel method for estimation of unsteady flow rate using pressure at two or three points along a pipeline is described in this paper. The pressure data are processed using a wave propagation model to determine the unsteady flow. The comparison and analysis of two-transducer and three-transducer techniques are investigated through simulation. The proposed method is shown to be effective for unsteady flow rate measurement over a high bandwidth. However, if the pressure values from two transducers are used, inaccuracies exist at certain frequencies when the transducer spacing coincides with multiples of half a wavelength. The accuracy can be improved by adding a third transducer with unequal spacing. The three-transducer method has been implemented in experiments and has been found to be robust and reliable.


2021 ◽  
pp. 13-19
Author(s):  
Zhanat А. Dayev ◽  
Gulzhan E. Shopanova ◽  
Bakytgul А. Toksanbaeva

The article deals with one of the important tasks of modern flow measurement, which is related to the measurement of the flow rate and the amount of wet gas. This task becomes especially important when it becomes necessary to obtain information about the separate amount of the dry part of the gas that is contained in the form of a mixture in the wet gas stream. The paper presents the principle of operation and structure of the invariant system for measuring the flow rate of wet gas, which is based on the combined use of differential pressure flowmeters and Coriolis flowmeters. The operation of the invariant wet gas flow rate measurement system is based on the simultaneous application of the multichannel principle and the partial flow measurement method. Coriolis flowmeters and the differential pressure flowmeter are used as the main elements of the system. The proposed measurement system does not offer applications for gases with abundant drip humidity. The article provides information about the test results of the proposed invariant system. The estimation of the metrological characteristics of the invariant system when measuring the flow rate of wet gas is given. The obtained test results of the invariant wet gas flow rate measurement system are relevant for natural gas production, transportation, and storage facilities.


Author(s):  
Mohd. Fua’ad Rahmat ◽  
Wee Lee Yaw

This paper discussed the electrostatic sensors that have been constructed for real–time mass flow rate measurement of particle conveying in a Pneumatic pipeline. Many industrial processes require continuous, smooth, and consistent delivery of solids materials with a high accuracy of controlled flow rate. This requirement can only be achieved by installing a proper measurement system. Electrostatic sensor offers the most inexpensive and simplest means of measuring solids flows in pipes. Key words: Electrostatic sensor, cross-correlation, peripheral velocity


2010 ◽  
Vol 32 (2) ◽  
pp. 345-351 ◽  
Author(s):  
Andreas Gutzeit ◽  
Michael A. Patak ◽  
Constantin von Weymarn ◽  
Nicole Graf ◽  
Aleksis Doert ◽  
...  