Experimental investigation of the properties of pharmaceutical aerosols with laser-based optical measurement techniques

Author(s):  
Sz. Kugler ◽  
A. Kerekes ◽  
A. Nagy ◽  
A. Czitrovszky
Author(s):  
Prasanna Hariharan ◽  
Ronald A. Robinson ◽  
Matthew R. Myers ◽  
Rupak K. Banerjee

A new, non-perturbing optical measurement technique was developed to characterize medical ultrasound fields generated by High Intensity Focused Ultrasound (HIFU) transducers using a phenomenon called ‘acoustic streaming’. The acoustic streaming velocity generated by HIFU transducers was measured experimentally using Digital Particle Image Velocimetry (DPIV). The streaming velocity was then calculated numerically using the finite-element method. An optimization algorithm was developed to back-calculate acoustic power and intensity field by minimizing the difference between experimental and numerical streaming velocities. The intensity field and acoustic power calculated using this approach was validated with standard measurement techniques. Results showed that the inverse method was able to predict acoustic power and intensity fields within 10% of the actual value measured using standard techniques, at the low powers where standard methods can be safely applied. This technique is also potentially useful for evaluating medical ultrasound transducers at the higher power levels used in clinical practice.


Author(s):  
Eren Billur ◽  
Muammer Koc¸

Hydraulic bulge testing is a material characterization method used as an alternative to tensile testing with the premise of accurately representing the material behavior to higher strain levels (∼70% as appeared to ∼30% in tensile test) in a biaxial stress mode. However, there are some major assumptions (such as continuous hemispherical bulge shape, thinnest point at apex) in hydraulic bulge analyses that lead to uncertainties in the resulting flow stress curves. In this paper, the effect of these assumptions on the accuracy and reliability of flow stress curves is investigated. The goal of this study is to determine the most accurate method for analyzing the data obtained from the bulge testing when continuous and in-line thickness measurement techniques are not available. Specifically, in this study the stress-strain relationships of two different materials (SS201 and Al5754) are obtained based on hydraulic bulge test data using various analysis methods for bulge radius and thickness predictions (e.g., Hill’s, Chakrabarty’s, Panknin’s theories, etc.). The flow stress curves are calculated using pressure and dome height measurements and compared to the actual 3-D strain measurement from a stereo optical and non-contact measurement system ARAMIS. In addition, the flow stress curves obtained from stepwise experiments are compared with the ones from above methods. Our findings indicate that Enikeev’s approach for thickness prediction and Panknin’s approach for bulge radius calculation result in the best agreement with both stepwise experiment results and 3D optical measurement results.


Author(s):  
Andrzej Gessner ◽  
Roman Staniek ◽  
Jakub Michałek

The hereby presented research, funded by the restricted grant LIDER, NCBiR, deals, in part, with the identification of the full implementation potential of the proposed optical measurement techniques in determination of surface flatness parameters, and their comparative assessment. The test methods included the photogrammetric measurement technique (TRITOP, GOM) and the structural light scanning approach (scanner ATOS, GOM), while the CMM measurement (DEA Global Image Clima) was the reference method. The accordingly designed and assembled experimental test stand comprised 2 steel plates. The test surfaces of the plates were appropriately ground; subsequently, the entire test stand was blackened to ascertain efficient optical scanning. Furthermore, the plates were connected by means of 8 screws, thus introducing considerable distortion. A measurement area of 140 × 240 mm was defined on the plate test surface, as determined by CMM, denoting 15 measurement paths of 240 mm in length, distributed every 10 mm, and characterized by measurement point densities of 1, 5, and 20 pt/mm. The reference CMM measurements were conducted on 3 consecutive days at different times (22 measurements in total) to exclude any possible surface modifications. Subsequently, optical scanning was applied and the measurement points lying at the cross-sections of the CMM measurement paths were isolated from the obtained polygon mesh. To further apply the photogrammetric method, the test surface was labeled with markers distributed every 10 mm and coinciding with the CMM measurement paths. Comparative analysis of the flatness parameter for the selected CMM measurement and the measurement values obtained by means of the tested optical methods included: - the entire measurement area, - the sections comprising 80, 60, 50, 45, 40, 30, 20, 15, and 10 % of the entire measurement area, decreasing centrically, - the measurement sub-areas of 30 × 50 mm allotted in the corners and in the center of the test plate. The photogrammetric error of the tested parameter was established at 1.26–19.82 %, depending on the size of the measurement area. The corresponding error value, as determined by the structural light scanning technique, amounted to 0.03–4.31 %.


Sign in / Sign up

Export Citation Format

Share Document