Application of energy-filtering TEM in contrast enhancement and elemental identification in IC failure analysis

Author(s):  
W. Zhang ◽  
S. Ng ◽  
D. Cheong ◽  
S. Lim
Author(s):  
H.T. Pearce-Percy

Recently an energy analyser of the uniform magnetic sector type has been installd in a 100KV microscope. This microscope can be used in the STEM mode. The sector is of conventional design (Fig. 1). The bending angle was chosen to be 90° for ease of construction. The bending radius (ρ) is 20 cm. and the object and image distances are 42.5 cm. and 30.0 cm. respectively.


Author(s):  
John R. Devaney

Occasionally in history, an event may occur which has a profound influence on a technology. Such an event occurred when the scanning electron microscope became commercially available to industry in the mid 60's. Semiconductors were being increasingly used in high-reliability space and military applications both because of their small volume but, also, because of their inherent reliability. However, they did fail, both early in life and sometimes in middle or old age. Why they failed and how to prevent failure or prolong “useful life” was a worry which resulted in a blossoming of sophisticated failure analysis laboratories across the country. By 1966, the ability to build small structure integrated circuits was forging well ahead of techniques available to dissect and analyze these same failures. The arrival of the scanning electron microscope gave these analysts a new insight into failure mechanisms.


Author(s):  
J W Steeds

That the techniques of convergent beam electron diffraction (CBED) are now widely practised is evident, both from the way in which they feature in the sale of new transmission electron microscopes (TEMs) and from the frequency with which the results appear in the literature: new phases of high temperature superconductors is a case in point. The arrival of a new generation of TEMs operating with coherent sources at 200-300kV opens up a number of new possibilities.First, there is the possibility of quantitative work of very high accuracy. The small probe will essentially eliminate thickness or orientation averaging and this, together with efficient energy filtering by a doubly-dispersive electron energy loss spectrometer, will yield results of unsurpassed quality. The Bloch wave formulation of electron diffraction has proved itself an effective and efficient method of interpreting the data. The treatment of absorption in these calculations has recently been improved with the result that <100> HOLZ polarity determinations can now be performed on III-V and II-VI semiconductors.


Author(s):  
Y. Taniguchi ◽  
E. Nakazawa ◽  
S. Taya

Imaging energy filters can add new information to electron microscopic images with respect to energy-axis, so-called electron spectroscopic imaging (ESI). Recently, many good results have been reported using this imaging technique. ESI also allows high-contrast observation of unstained biological samples, becoming a trend of the field of morphology. We manufactured a new type of energy filter as a trial production. This energy filter consists of two magnets, and we call γ-filter since the trajectory of electrons shows ‘γ’-shape inside the filter. We evaluated the new energyγ-filter TEM with the γ-filter.Figure 1 shows schematic view of the electron optics of the γ-type energy filter. For the determination of the electron-optics of the γ-type energy filter, we used the TRIO (Third Order Ion Optics) program which has been developed for the design of high resolution mass spectrometers. The TRIO takes the extended fringing fields (EFF) into consideration. EFF makes it difficult to design magnetic energy filters with magnetic sector fields.


Author(s):  
Evelyn R. Ackerman ◽  
Gary D. Burnett

Advancements in state of the art high density Head/Disk retrieval systems has increased the demand for sophisticated failure analysis methods. From 1968 to 1974 the emphasis was on the number of tracks per inch. (TPI) ranging from 100 to 400 as summarized in Table 1. This emphasis shifted with the increase in densities to include the number of bits per inch (BPI). A bit is formed by magnetizing the Fe203 particles of the media in one direction and allowing magnetic heads to recognize specific data patterns. From 1977 to 1986 the tracks per inch increased from 470 to 1400 corresponding to an increase from 6300 to 10,800 bits per inch respectively. Due to the reduction in the bit and track sizes, build and operating environments of systems have become critical factors in media reliability.Using the Ferrofluid pattern developing technique, the scanning electron microscope can be a valuable diagnostic tool in the examination of failure sites on disks.


Author(s):  
S. Lehner ◽  
H.E. Bauer ◽  
R. Wurster ◽  
H. Seiler

In order to compare different microanalytical techniques commercially available cation exchange membrane SC-1 (Stantech Inc, Palo Alto), was loaded with biologically relevant elements as Na, Mg, K, and Ca, respectively, each to its highest possible concentration, given by the number concentration of exchangeable binding sites (4 % wt. for Ca). Washing in distilled water, dehydration through a graded series of ethanol, infiltration and embedding in Spurr’s low viscosity epoxy resin was followed by thin sectioning. The thin sections (thickness of about 50 nm) were prepared on carbon foils and mounted on electron microscopical finder grids.The samples were analyzed with electron microprobe JXA 50A with transmitted electron device, EDX system TN 5400, and on line operating image processing system SEM-IPS, energy filtering electron microscope CEM 902 with EELS/ESI and Auger spectrometer 545 Perkin Elmer.With EDX, a beam current of some 10-10 A and a beam diameter of about 10 nm, a minimum-detectable mass of 10-20 g Ca seems within reach.


Author(s):  
L. D. Peachey ◽  
J. P. Heath ◽  
G. Lamprecht

Biological specimens of cells and tissues generally are considerably thicker than ideal for high resolution transmission electron microscopy. Actual image resolution achieved is limited by chromatic aberration in the image forming electron lenses combined with significant energy loss in the electron beam due to inelastic scattering in the specimen. Increased accelerating voltages (HVEM, IVEM) have been used to reduce the adverse effects of chromatic aberration by decreasing the electron scattering cross-section of the elements in the specimen and by increasing the incident electron energy.


Author(s):  
Karen F. Han

The primary focus in our laboratory is the study of higher order chromatin structure using three dimensional electron microscope tomography. Three dimensional tomography involves the deconstruction of an object by combining multiple projection views of the object at different tilt angles, image intensities are not always accurate representations of the projected object mass density, due to the effects of electron-specimen interactions and microscope lens aberrations. Therefore, an understanding of the mechanism of image formation is important for interpreting the images. The image formation for thick biological specimens has been analyzed by using both energy filtering and Ewald sphere constructions. Surprisingly, there is a significant amount of coherent transfer for our thick specimens. The relative amount of coherent transfer is correlated with the relative proportion of elastically scattered electrons using electron energy loss spectoscopy and imaging techniques.Electron-specimen interactions include single and multiple, elastic and inelastic scattering. Multiple and inelastic scattering events give rise to nonlinear imaging effects which complicates the interpretation of collected images.


Author(s):  
James F. Mancuso ◽  
Leo A. Fama ◽  
William B. Maxwell ◽  
Jerry L. Lehman ◽  
Hasso Weiland ◽  
...  

Micro-diffraction based crystallography is essential to the design and development of many classes of ‘crafted materials’. Although the scanning electron microscope can provide crystallographic information with high spatial resolution, its current utility is severely limited by the low sensitivity of existing diffraction techniques (ref: Dingley). Previously, Joy showed that energy filtering increased contrast and pattern visibility in electron channelling. This present paper discribes the effect of energy filtering on EBSP sensitivity and backscattered SEM imaging.The EBSP detector consisted of an electron energy filter, a microchannel plate detector, a phosphor screen, optical coupler, and a slow scan CCD camera. The electrostatic energy filter used in this experiment was constructed as a cone with 5 coaxial electrodes. The angular field-of-view of the filter was approximately 38°. The microchannel plate, which was the initial sensing component, had high gain and had 50% to 80% detection efficiency for the low energy electrons that passed through the retarding field filter.


Sign in / Sign up

Export Citation Format

Share Document