Generation of coherent continua in soft X rays using a carrier-envelope phase-controlled few-cycle infrared light source

Author(s):  
N. Ishii ◽  
K. Kaneshima ◽  
K. Kitano ◽  
T. Kanai ◽  
S. Watanabe ◽  
...  
2020 ◽  
Vol 5 (1) ◽  
pp. 109-118 ◽  
Author(s):  
Debabrata Maiti ◽  
Jing Zhong ◽  
Zheng Zhang ◽  
Hailin Zhou ◽  
Saisai Xion ◽  
...  

X-rays with high deep tissue penetration could be acted as an excellent excited light source for enhanced photodynamic therapy (PDT), avoiding the weak penetration of near-infrared light and further improving the therapeutic efficiency of PDT.


2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Mary K. Popp ◽  
Imane Oubou ◽  
Colin Shepherd ◽  
Zachary Nager ◽  
Courtney Anderson ◽  
...  

Photothermal therapy (PTT) treatments have shown strong potential in treating tumors through their ability to target destructive heat preferentially to tumor regions. In this paper we demonstrate that PTT in a murine melanoma model using gold nanorods (GNRs) and near-infrared (NIR) light decreases tumor volume and increases animal survival to an extent that is comparable to the current generation of melanoma drugs. GNRs, in particular, have shown a strong ability to reach ablative temperatures quickly in tumors when exposed to NIR light. The current research tests the efficacy of GNRs PTT in a difficult and fast growing murine melanoma model using a NIR light-emitting diode (LED) light source. LED light sources in the NIR spectrum could provide a safer and more practical approach to photothermal therapy than lasers. We also show that the LED light source can effectively and quickly heatin vitroandin vivomodels to ablative temperatures when combined with GNRs. We anticipate that this approach could have significant implications for human cancer therapy.


2021 ◽  
Author(s):  
Ugaitz Elu ◽  
Luke Maidment ◽  
Lenard Vamos ◽  
Francesco Tani ◽  
David Novoa ◽  
...  

2010 ◽  
Vol 173 ◽  
pp. 1-6 ◽  
Author(s):  
Haider F. Abdul Amir ◽  
Fuei Pien Chee

In this research, optoelectronic devices consisted of an infrared light emitting diode and a phototransistor with no special handling or third party-packaging were irradiated to ionizing radiation utilizing x-rays. It was found that the devices under test (DUTs) undergo performance degradation in their functional parameters during exposure to x-rays. These damaging effects are depending on their current drives and also the Total Ionizing Dose (TID) absorbed. The TID effects by x-rays are cumulative and gradually take place throughout the lifecycle of the devices exposed to radiation.


Author(s):  
Erik Krenzen ◽  
Louis M. Kehlet ◽  
Peter Tidemand-Lichtenberg ◽  
Jeppe S. Dam ◽  
Ole B. Jensen ◽  
...  

2020 ◽  
Vol 27 (3) ◽  
pp. 737-745
Author(s):  
Zhijun Chi ◽  
Yingchao Du ◽  
Wenhui Huang ◽  
Chuanxiang Tang

A Thomson scattering X-ray source can provide quasi-monochromatic, continuously energy-tunable, polarization-controllable and high-brightness X-rays, which makes it an excellent tool for X-ray fluorescence computed tomography (XFCT). In this paper, we examined the suppression of Compton scattering background in XFCT using the linearly polarized X-rays and the implementation feasibility of linearly polarized XFCT based on this type of light source, concerning the influence of phantom attenuation and the sampling strategy, its advantage over K-edge subtraction computed tomography (CT), the imaging time, and the potential pulse pile-up effect by Monte Carlo simulations. A fan beam and pinhole collimator geometry were adopted in the simulation and the phantom was a polymethyl methacrylate cylinder inside which were gadolinium (Gd)-loaded water solutions with Gd concentrations ranging from 0.2 to 4.0 wt%. Compared with the case of vertical polarization, Compton scattering was suppressed by about 1.6 times using horizontal polarization. An accurate image of the Gd-containing phantom was successfully reconstructed with both spatial and quantitative identification, and good linearity between the reconstructed value and the Gd concentration was verified. When the attenuation effect cannot be neglected, one full cycle (360°) sampling and the attenuation correction became necessary. Compared with the results of K-edge subtraction CT, the contrast-to-noise ratio values of XFCT were improved by 2.03 and 1.04 times at low Gd concentrations of 0.2 and 0.5 wt%, respectively. When the flux of a Thomson scattering light source reaches 1013 photons s−1, it is possible to finish the data acquisition of XFCT at the minute or second level without introducing pulse pile-up effects.


2021 ◽  
Author(s):  
Daniel DiCenzo DiCenzo

Gold nanoparticles (GNP) have been shown to highly absorb ionizing radiation compared to tissue. GNPs have also been shown to be high absorbers of non-ionizing radiation with a peak absorbance at a wavelength dependent on their shape and size. This study investigated radiation dose enhancement in PC3 cells when in the presence of gold nanorods (NR) and near infrared light (IR). The PC3 cells were incubated with either PEGylated NRs (PNR) or anti prostate stem cell antigen antibody with nuclear localization sequence peptide conjugated NRs (AbNR). They were exposed to near infrared light at a wavelength of 810 nm to achieve a temperature of 42 ºC to 43 ºC for 60 minutes. They were also exposed to 160 kVp x-rays. It was found that both targeted and non-targeted GNPs when exposed to radiation and near infrared light synergistically enhanced radiation dose. It was also found that AbNRs provide greater dose enhancement than PNRs.


2017 ◽  
Vol 46 (9) ◽  
pp. 917007 ◽  
Author(s):  
卢新然 Lu Xinran ◽  
宋 路 Song Lu ◽  
万秋华 Wan Qiuhua

Sign in / Sign up

Export Citation Format

Share Document