Modeling, development & analysis of low cost device for water quality testing

Author(s):  
K. Indu ◽  
Jishmi Jos Choondal
Water ◽  
2020 ◽  
Vol 12 (1) ◽  
pp. 240 ◽  
Author(s):  
Carolina Bernardes ◽  
Ricardo Bernardes ◽  
Camille Zimmer ◽  
Caetano C. Dorea

There is a need for accessible and low-cost microbiological water quality testing in contexts where diarrheal illness is a major public health concern. In most cases, the quantification of Escherichia coli and other microbial indicators by conventional culture methods requires an incubation step for processed samples at specific temperatures for bacterial growth over a prescribed time. However, incubators can be the most expensive equipment required for such microbial analyses, limiting the number and scope of water quality testing available in low-resource contexts. In this study, a low-cost incubator was developed using a locally available expanded polystyrene (EPS) foam cooler, with two water bottles filled with hot water to heat incubator to a target of 35 °C. The EPS incubator performance was validated by processing 150 water samples in duplicates using the Colilert Quanti-tray/2000 system, incubated in either the EPS incubator or a standard laboratory incubator set at 35 °C. Statistically significant correlations of results indicated that the quantification of E. coli was comparable between both methods. Risk categorizations from standard and EPS incubation results agreed for 141 of 150 (94%) samples, with zero false negatives. In addition to being reasonably mobile the EPS incubator would reduce the cost of such water quality testing, thus potentially increasing the scope of water quality testing coverage.


2014 ◽  
Vol 4 (3) ◽  
pp. 532-537 ◽  
Author(s):  
Bas Wijnen ◽  
G. C. Anzalone ◽  
Joshua M. Pearce

The developing world remains plagued by lack of access to safe drinking water. Although many low-cost methods have been developed to treat contaminated water, low-cost methods for water-quality testing are necessary to determine if these appropriate technologies are needed, effective, and reliable. This paper provides a methodology for the design, development, and technical validation of a low-cost, open-source (OS) water testing platform. A case study is presented where the platform is developed to provide both the colorimetry for biochemical oxygen demand/chemical oxygen demand and nephelometry to measure turbidity using method ISO 7027. This approach resulted in equipment that is as accurate, but costs between 7.5 and 15 times less than current commercially available tools. It is concluded that OS hardware development is a promising solution for the equipment necessary to perform water quality measurements in both developed and developing regions.


Author(s):  
MD. Reza Ranjbar ◽  
Aisha H. Abdalla

<p>Due to the vast increase in global industrial output, rural to urban drift and the over-utilization of land and sea resources, the quality of water available to people has deteriorated greatly. Before the sensor based approach to water quality monitoring, water quality was tested by collecting the samples of water and experimentally analyzing it in the laboratories. However, in today, with time being a scarce resource, the traditional method of water quality testing is not efficient anymore. To tackle this issue, several electronic (microcontroller and sensor based) water quality monitoring systems were developed in the past decade. However, an in depth study of this current water quality testing technology shows that there are some limitations that should be taken into consideration. Therefore, an automatic, remote, and low cost water quality monitoring system has been developed. This system consists of a core microcontroller, multiple sensors, GSM module, LCD display screen, and an alarm subsystem. The quality of water is read from the physical world through the water quality testing sensors and sent to the microcontroller. The data is then analyzed by the microcontroller and the result is displayed on the LCD screen on the device. At the same time, another copy of the sensor readings is sent remotely to the user’s mobile phone in the form of SMS. If an abnormal water quality parameter is detected by any sensor, the alarm system will turn on the respective red LED for that parameter and the buzzer will give warning sound. At the same time, the abnormality of the water parameter is reported to the user through SMS. The system is aimed to be used for wide applications and by all categories of users. It can facilitate the process of water quality monitoring autonomously and with low cost; to help people improve their quality of drinking water, household water supplies and aquaculture farms, especially in rural areas where residents do not have access to standardized water supply and suffer from different diseases caused by contaminated water.</p>


Micromachines ◽  
2020 ◽  
Vol 11 (5) ◽  
pp. 474 ◽  
Author(s):  
Bei Wang ◽  
Manuel Baeuscher ◽  
Xiaodong Hu ◽  
Markus Woehrmann ◽  
Katharina Becker ◽  
...  

A novel capacitive sensor for measuring the water-level and monitoring the water quality has been developed in this work by using an enhanced screen printing technology. A commonly used environment-friendly conductive polymer poly(3,4-ethylenedioxythiophene):poly (styrenesulfonate) (PEDOT:PSS) for conductive sensors has a limited conductivity due to its high sheet resistance. A physical treatment performed during the printing process has reduced the sheet resistance of printed PEDOT:PSS on polyethylenterephthalat (PET) substrate from 264.39 Ω/sq to 23.44 Ω/sq. The adhesion bonding force between printed PEDOT:PSS and the substrate PET is increased by using chemical treatment and tested using a newly designed adhesive peeling force test. Using the economical conductive ink PEDOT:PSS with this new physical treatment, our capacitive sensors are cost-efficient and have a sensitivity of up to 1.25 pF/mm.


2019 ◽  
Author(s):  
Jeba Anandh S ◽  
Anandharaj M ◽  
Aswinrajan J ◽  
Karankumar G ◽  
Karthik P

2011 ◽  
Vol 1 (1) ◽  
pp. 68-85 ◽  
Author(s):  
Patty Chuang ◽  
Stephanie Trottier ◽  
Susan Murcott

The UN defines water supplies as ‘improved’ or ‘unimproved.’ These indicators are easy to measure, but do not reflect water quality, which requires laboratory or field tests. Laboratory and test availability, expense and technical capacity are obstacles for developing countries. This research compares and verifies four low-cost, field-based microbiological tests: the EC-Kit (Colilert® and Petrifilm™ tests), the H2S bacteria test, and Easygel®, against a standard method (Quanti-Tray®). The objectives are to: (1) verify the accuracy of the four field-based tests, (2) study the accuracy of these tests as a function of improved and unimproved sources; (3) recommend a single microbiological test, if appropriate, based on accuracy and cost, and/or (4) recommend a testing combination, if appropriate, based on accuracy and cost. The tests of 500+ total water samples from Capiz Province, Philippines and Cambridge, MA indicate that two-tests systems gave better results than a single test. Both the 100-mL H2S test + Petrifilm™ and the 20-mL H2S test + Easygel® combinations yield promising results, in addition to being inexpensive. None of the field-based tests should be used on their own. We recommend further verification of a larger sample size and scale be undertaken before these testing combinations are recommended for wider use.


Water Policy ◽  
2017 ◽  
Vol 19 (6) ◽  
pp. 1206-1224 ◽  
Author(s):  
Charles Yaw Okyere ◽  
Felix Ankomah Asante

Abstract In this paper, we analyze perceptions and determinants of households' participation in a randomized experiment on water quality testing and information in southern Ghana. Beneficiary households assessed the components of the intervention including its relevance and adequacy in improving understanding of water quality issues. Motivating and constraining factors to participation in the randomized experiment are also assessed. We also estimate the correlates of participation in the intervention. Social and economic benefits derived from the intervention based on perceptions are compared with impacts of the intervention using an instrumental variable approach. We found evidence that subjective analysis estimates of the effects of the intervention are higher than the objective analysis estimates. Households generally perceived the intervention to be relevant in improving their understanding of water quality issues. However, there are differing opinions based on random assignment into either child or adult treatment groups on most- and least-liked attributes of the intervention, and also motivating and constraining factors affecting participation in the intervention. The factors that statistically and significantly influenced participation in the intervention include educational attainment, ethnicity, religious denomination and marital status of the household heads, in addition to the location of residence.


Sign in / Sign up

Export Citation Format

Share Document