Effect of Ultrasound Probe on Dose Delivery During Real-time Ultrasound-Guided Tumor Tracking

Author(s):  
Jianzhou Wu ◽  
Omkar Dandekar ◽  
Daryl Nazareth ◽  
Peng Lei ◽  
Warren D'Souza ◽  
...  
2018 ◽  
Vol 128 (1) ◽  
pp. 38-43 ◽  
Author(s):  
Christian Breschan ◽  
Gudrun Graf ◽  
Robert Jost ◽  
Haro Stettner ◽  
Georg Feigl ◽  
...  

Abstract Background The aim of this retrospective analysis was to evaluate the clinical effectiveness of the supraclavicular ultrasound-guided cannulation of the brachiocephalic vein in preterm infants. Methods The ultrasound probe was placed in the supraclavicular region so as to obtain the optimum sonographic long-axis view of the brachiocephalic vein. By using a strict in-plane approach the brachiocephalic vein was cannulated by advancing a 22- or 24-gauge iv cannula from lateral to medial under the long axis of the ultrasound probe under real-time ultrasound guidance into the vein. Results One hundred and forty-two cannulations in infants weighing between 0.59 and 2.5 kg (median: 2.1; CI: 2.0 to 2.2) were included. Ultimate success rate was 94% (134 of 142). One cannulation attempt was required in 100 (70%) patients, two attempts in 21 (15%), and three attempts in 13 (9%). The smaller the weight of the infant the more attempts were needed. More attempts also were needed for the right brachiocephalic vein, which was primarily targeted in 75 (53%) neonates. One (1%) inadvertent arterial puncture was noted. Conclusions This supraclavicular, in-plane, real-time, ultrasound-guided cannulation of the brachiocephalic vein seems to be a convenient and effective method to insert central venous catheters in preterm infants.


2020 ◽  
Vol 152 ◽  
pp. S870-S871
Author(s):  
C. Murillo ◽  
S. Seeber ◽  
P. Haering ◽  
C. Lang ◽  
M. Splinter

2021 ◽  
pp. 155335062199779
Author(s):  
Difu Fan ◽  
Leming Song ◽  
Monong Li ◽  
Chunxiang Luo ◽  
Xiaohui Liao ◽  
...  

Objective. The objective is to explore the clinical application value of ultrasound long- and short-axis planar technology in real-time guided puncture in minimally invasive percutaneous nephrology. Methods. The clinical data of 80 patients undergoing real-time ultrasound-guided minimally invasive percutaneous nephrolithotomy from September 2018 to October 2019 were analyzed. The patients were randomly divided into 2 groups with different ultrasound-guided puncture techniques, long-axis in-plane technique and short-axis out-of-plane technique. Results. Minimally invasive percutaneous nephrolithotomies under real-time ultrasound guidance were successfully completed in both groups of patients. The success rate of the first puncture in the short-axis out-of-plane group was significantly higher than that in the long-axis in-plane group, and the differences were statistically significant ( P <.05); the total puncture time in the short-axis out-of-plane group was significantly less than the long-axis in-plane group, and the differences were statistical significance ( P <.05); there was no significant difference in the single-stage stone removal rate, total percutaneous renal channels, total hospital stay, and rate of complications by the Clavien classification between the 2 groups ( P > .05). Conclusion. Ultrasound long-axis and short-axis planar technologies can achieve good clinical application results in real-time guided puncture to establish percutaneous renal channels during minimally invasive percutaneous nephrolithotomy. Compared with the long-axis in-plane technique, the short-axis out-of-plane technique can shorten the puncture time and improve the success rate of the first puncture.


2021 ◽  
pp. 2102256
Author(s):  
Tao Sun ◽  
Guangping Zhang ◽  
Tingting Ning ◽  
Qinjun Chen ◽  
Yongchao Chu ◽  
...  

Author(s):  
Nazanin Tahmasebi ◽  
Pierre Boulanger ◽  
Jihyun Yun ◽  
Gino Fallone ◽  
Michelle Noga ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document