Harmonic characteristics on 20 kV - medium voltage distribution and low voltage network in PT. PLN distribution West Java and Banten

Author(s):  
Agus Purwadi ◽  
Anang Mawardi ◽  
Pranyoto ◽  
Muhammad Firmansyah ◽  
Nana Heryana ◽  
...  
Author(s):  
Benbouza Naima ◽  
Benfarhi Louiza ◽  
Azoui Boubekeur

Background: The improvement of the voltage in power lines and the respect of the low voltage distribution transformer substations constraints (Transformer utilization rate and Voltage drop) are possible by several means: reinforcement of conductor sections, installation of new MV / LV substations (Medium Voltage (MV), Low Voltage (LV)), etc. Methods: Connection of mini-photovoltaic systems (PV) to the network, or to consumers in underserved areas, is a well-adopted solution to solve the problem of voltage drop and lighten the substation transformer, and at the same time provide clean electrical energy. PV systems can therefore contribute to this solution since they produce energy at the deficit site. Results: This paper presents the improvement of transformer substation constraints, supplying an end of low voltage electrical line, by inserting photovoltaic systems at underserved subscribers. Conclusion: This study is applied to a typical load pattern, specified to the consumers region.


2016 ◽  
Vol 6 (1) ◽  
pp. 252-260
Author(s):  
Hiroshi Kikusato ◽  
Jun Yoshinaga ◽  
Yu Fujimoto ◽  
Yasuhiro Hayashi ◽  
Shinichi Kusagawa ◽  
...  

Rekayasa ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 431-442
Author(s):  
Martinus W Djagolado ◽  
Amirullah Amirullah ◽  
Saidah Saidah

The use of electrical equipment on the customer side with low voltage absorbs unbalanced power. The load unbalances in each phase will result in an unbalanced current, resulting in a phase voltage shift in the secondary coil of the 20 kV/380 V medium voltage transformer. Shifting the voltage in the distribution transformer phase, then causes the flow of current in the transformer neutral wire causing losses. This paper proposes a fuzzy logic method with the Mamdani fuzzy inference system (FIS) to balance three-phase load currents at seven feeders of 20 kV medium voltage distribution at PLN Rayon Taman Jawa-Timur. The feeders are Ngelom, Tawang Sari, Geluran, Bringin, Masangan Kulon, Palm Residence, and Pasar Sepanjang. There are three input variables used, namely the load current in phase R, phase S, and phase T respectively. There are three output variables in one FIS block, namely changes in load current in phase R, phase S, and phase T respectively. With the number of fuzzy rules as many as 509 rules, the proposed method is able to produce the lowest load current unbalance value of 1.6% at Palm Residence Feeders. The development of a nominal (number) of fuzzy rules in the Fuzzy Logic Method with FIS Mamdani is able to reduce the value of unbalance load current at the 20 kV medium voltage distribution feeder better than the method proposed by previous researchers.


2016 ◽  
Vol 136 (11) ◽  
pp. 878-883 ◽  
Author(s):  
Kazunori Nishimura ◽  
Yusaku Marui ◽  
Satonori Nishimura ◽  
Wataru Sunayama

2013 ◽  
Vol 133 (4) ◽  
pp. 343-349
Author(s):  
Shunsuke Kawano ◽  
Yasuhiro Hayashi ◽  
Nobuhiko Itaya ◽  
Tomihiro Takano ◽  
Tetsufumi Ono

Sign in / Sign up

Export Citation Format

Share Document