Flue Gas Heat Recovery in High Efficient Coal-fired Power Plant

Author(s):  
Janusz Buchta ◽  
Andrzej Oziemski
Entropy ◽  
2018 ◽  
Vol 21 (1) ◽  
pp. 19 ◽  
Author(s):  
Enhui Sun ◽  
Han Hu ◽  
Hangning Li ◽  
Chao Liu ◽  
Jinliang Xu

It is difficult to recover the residual heat from flue gas when supercritical carbon dioxide (S-CO2) cycle is used for a coal fired power plant, due to the higher CO2 temperature in tail flue and the limited air temperature in air preheater. The combined cycle is helpful for residual heat recovery. Thus, it is important to build an efficient bottom cycle. In this paper, we proposed a novel exergy destruction control strategy during residual heat recovery to equal and minimize the exergy destruction for different bottom cycles. Five bottom cycles are analyzed to identify their differences in thermal efficiencies (ηth,b), and the CO2 temperature entering the bottom cycle heater (T4b) etc. We show that the exergy destruction can be minimized by a suitable pinch temperature between flue gas and CO2 in the heater via adjusting T4b. Among the five bottom cycles, either the recompression cycle (RC) or the partial cooling cycle (PACC) exhibits good performance. The power generation efficiency is 47.04% when the vapor parameters of CO2 are 620/30 MPa, with the double-reheating-recompression cycle as the top cycle, and RC as the bottom cycle. Such efficiency is higher than that of the supercritical water cycle power plant.


2014 ◽  
Vol 61 ◽  
pp. 2558-2561 ◽  
Author(s):  
Yingying Xiong ◽  
Yanqing Niu ◽  
Xuebin Wang ◽  
Houzhang Tan

Energy ◽  
2012 ◽  
Vol 48 (1) ◽  
pp. 196-202 ◽  
Author(s):  
Chaojun Wang ◽  
Boshu He ◽  
Shaoyang Sun ◽  
Ying Wu ◽  
Na Yan ◽  
...  

2016 ◽  
Vol 20 (1) ◽  
pp. 303-314
Author(s):  
Changchun Xu ◽  
Min Xu ◽  
Ming Zhao ◽  
Junyu Liang ◽  
Juncong Sai ◽  
...  

In a utility boiler, the most heat loss is from the exhaust flue gas. In order to reduce the exhaust flue gas temperature and further boost the plant efficiency, an improved indirect flue gas heat recovery system and an additional economizer system are proposed. The waste heat of flue gas is used for high-pressure condensate regeneration heating. This reduces high pressure steam extraction from steam turbine and more power is generated. The waste heat recovery of flue gas decreases coal consumption. Other approaches for heat recovery of flue gas, direct utilization of flue gas energy and indirect flue gas heat recovery system, are also considered in this work. The proposed systems coupled with a reference 330MWe power plant are simulated using equivalent enthalpy drop method. The results show that the additional economizer scheme has the best performance. When the exhaust flue gas temperature decreases from 153? to 123?, power output increases by 6.37MWe and increment in plant efficiency is about 1.89%. For the improved indirect flue gas heat recovery system, power output increases by 5.68MWe and the increment in plant efficiency is 1.69%.


2016 ◽  
Vol 37 (1) ◽  
pp. 87-98 ◽  
Author(s):  
Janusz Kotowicz ◽  
Marcin Job

Abstract The paper presents the structure and parameters of advanced zero emission power plant (AZEP). This concept is based on the replacement of the combustion chamber in a gas turbine by the membrane reactor. The reactor has three basic functions: (i) oxygen separation from the air through the membrane, (ii) combustion of the fuel, and (iii) heat transfer to heat the oxygen-depleted air. In the discussed unit hot depleted air is expanded in a turbine and further feeds a bottoming steam cycle (BSC) through the main heat recovery steam generator (HRSG). Flue gas leaving the membrane reactor feeds the second HRSG. The flue gas consist mainly of CO2 and water vapor, thus, CO2 separation involves only the flue gas drying. Results of the thermodynamic analysis of described power plant are presented.


Author(s):  
Jiayou Liu ◽  
Fengzhong Sun ◽  
Wei Wei ◽  
Lei Ma

Recovering the waste heat of flue gas to reduce its temperature with avoiding low-temperature corrosion is an effective way to improve the economic efficiency of coal-fired power plant. A coupled high-low energy level flue gas heat recovery system was introduced in the paper. The inlet air temperature of air preheater and the temperature of turbine condensate can be increased by using this system. Thermal economy model of the system was built based on equivalent heat drop method. The system was successfully applied in 1000MW ultra-supercritical double reheat coal-fired unit in Laiwu Power Plant of China Huaneng Group, and the operation data showed the boiler flue gas temperature was not higher than 90° C, and the coal consumption was reduced by using the system. (CSPE)


Sign in / Sign up

Export Citation Format

Share Document