Numerical approach for thermal analysis of heat transfer into a very narrow air gap of a totally enclosed permanent magnet integrated starter generator

Author(s):  
Ayoub Ben Nachouane ◽  
Abdenour Abdelli ◽  
Guy Friedrich ◽  
Stephane Vivier
2018 ◽  
Author(s):  
Massimo Milani ◽  
Luca Montorsi ◽  
Matteo Venturelli

The paper studies the ventilated façade as a potential alternative to conventional coating technologies for the thermal insulation of building’s external walls. The ventilated façade is modeled by means of a CFD approach that accounts for the full 3D-geometry of the building, the walls thickness and materials’ thermal properties. The effects of the windows on the heat losses and in the performance of the ventilated façade are modeled in order to accurately characterize the thermal behavior of the system. The solar radiative heat transfer during two representative days of the year is considered in the analysis and a multiband thermal radiation is adopted to capture the different nature of radiative heat exchange according to the light wavelengths. The numerical approach enables to estimate the thermo-fluid dynamic behavior of the system and the temperature distribution and the velocity flow field within the air gap between the walls are addressed and their influence on the heat transfer through the building’s external walls is determined. The CFD analysis is employed to compare different configurations of the ventilated façade for improving the thermal insulation of the building; the performance of each scenario is determined in terms of electric energy and fuel consumption for the air conditioning and the heating system. Thus, the potential saving of the energy cost for ambient thermal conditioning is evaluated. The analysis investigates the effects on the energy efficiency of different geometrical features of the system such as the height of the building and the air gap thickness and theoretical correlations are derived in order to estimate the best tradeoff between the energy efficiency of the building and the investment of the ventilated façade configuration.


2005 ◽  
Author(s):  
Julien Pelle´ ◽  
Rachid Boutarfa ◽  
Souad Harmand

This paper deals with flow structure and heat transfer modeling in a two coaxial disk air-gap. Numerical estimations for the local Nusselt number on the rotor, for the radial and tangential velocities are compared with experimental results obtained using PIV and infrared thermography. Models used for the numerical approach are then validated for a turbulent Reynolds Number.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2983 ◽  
Author(s):  
Abdalla Mohamed ◽  
Ahmed Hemeida ◽  
Hendrik Vansompel ◽  
Peter Sergeant

In this paper, the effect of some geometrical parameters on the steady state average temperature of the stator core, the winding and the permanent magnets of the yokeless and segmented armature (YASA) axial flux permanent magnet synchronous machine (AFPMSM) is studied. The geometrical parameters selected for the study are the air gap length, the inward heat extraction fin thickness and the permanent magnet thickness. These parametric studies make it possible to obtain a better trade-off between power density and efficiency. These investigations are very helpful in correlating the values of the geometrical parameters to some specific desired performance criteria like not going below some desired minimum efficiency, limiting the temperature of specific part to some maximum value for maximization of lifetime and also determination of the allowed speed range to limit the temperatures lower than the critical values. This is important specifically for the synchronous machines due to the fact that the speed value affects both the losses and the heat transfer convection coefficients. The air gap length has a direct effect on the overall machine losses and the air gap convection coefficient and hence on the temperature of the machine. As the fins are between the stator windings, a thicker fin reduces the space for copper windings and hence increases the losses, but at the same time improves heat evacuation. In addition, the effect on the temperature is studied of the speed variation, which influences both the losses and the convection coefficients of the machine. Every study is made based on coupled electromagnetic and thermal models. The results are obtained from analytical electromagnetic and thermal models verified by finite element simulations and validated experimentally on a 4 kW yokeless and segmented armature axial flux machine.


Author(s):  
Jianqi Li ◽  
Yu Zhou ◽  
Jianying Li

This paper presented a novel analytical method for calculating magnetic field in the slotted air gap of spoke-type permanent-magnet machines using conformal mapping. Firstly, flux density without slots and complex relative air-gap permeance of slotted air gap are derived from conformal transformation separately. Secondly, they are combined in order to obtain normalized flux density taking account into the slots effect. The finite element (FE) results confirmed the validity of the analytical method for predicting magnetic field and back electromotive force (BEMF) in the slotted air gap of spoke-type permanent-magnet machines. In comparison with FE result, the analytical solution yields higher peak value of cogging torque.


2012 ◽  
Vol 43 (8) ◽  
pp. 749-765 ◽  
Author(s):  
Song He ◽  
Dongmei Huang ◽  
Zhengkun Qi ◽  
Hui Yang ◽  
Yin Hu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document