Harmonic-based determination of soft switching boundaries for 3-level modulated single-phase dual active bridge converters

Author(s):  
J. Riedel ◽  
D. G. Holmes ◽  
C. Teixeira ◽  
B. P. McGrath
2016 ◽  
Vol 64 (3) ◽  
pp. 561-574
Author(s):  
R. Barlik ◽  
M. Nowak ◽  
P. Grzejszczak ◽  
M. Zdanowski

Abstract The paper presents an analytical approach to the determination of power losses in a high-frequency transformer operating in the dual active bridge (DAB). This transformer, having two single-phase transistor bridge inverters, couples two DC circuits that significantly differ in voltages (280 V and 51 V ±20%). Power losses in the core and windings of the planar transformer 5600 VA /100 kHz were calculated taking into account changes in the value and direction of the energy flow between the coupled DC circuits. These circuits represent storage or renewable energy sources and intermediate circuits of the converters used in distributed generation systems. Calculations were performed using the Steinmetz’s and Dowell’s equations. The analytical results have been verified experimentally.


Author(s):  
Olympio Cipriano da Silva ◽  
Fernando Lessa Tofoli ◽  
Dalton Honorio ◽  
Luiz Henrique Silva Colado Barreto ◽  
Demercil De Souza Oliveira

Fuel ◽  
2022 ◽  
Vol 307 ◽  
pp. 121837
Author(s):  
Samara Soares ◽  
Gabriel M. Fernandes ◽  
Liz M.B. Moraes ◽  
Alex D. Batista ◽  
Fábio R.P. Rocha