Active and reactive power management of photovoltaic-based interline dynamic voltage restorer in low voltage distribution networks

Author(s):  
A. Elserougi ◽  
A. S. Abdel-Khalik ◽  
S. Ahmed ◽  
A. Massoud
Author(s):  
Mahmoud Zadehbagheri ◽  
Rahim Ildarabadi ◽  
Majid Baghaei Nejad ◽  
Tole Sutikno

As a consequence of sensitive, diverse and complex loads in today's distribution networks, improving power quality in distribution systems has attracted great attention. Power quality issues involve voltage sags, transient interrupts and other distortions in sinusoidal waveforms. Enormous methods have been proposed for power quality modification. One of the methods by which power quality problems might be addressed is to apply power electronic devices in the form of custom power devices. One of such devices is Dynamic Voltage Restorer (DVR) which is connected in series to distribution networks. At the same time, through injection of voltage to the network it is able to control voltage amplitude and phase. It is adopted lend to compensate for voltage sags through injecting series and synchronous three phase voltage. Consisted of three single phase inverters and a DC bus, it can protect susceptible loads against various types of voltage sags as well as other disturbances in the power supply. Moreover, it is capable of generating and absorbing active and reactive power. Therefore, in this paper, different structures of  DVR have been investigated and eventually proposed a new structure for DVR based on Γ-Source asymmetric inverter. With the proposed structure, severe voltage sags can be retrieved 80- 90 percent. The simulation results that obtained by using MATLAB/Simulink indicate the properly functioning of proposed structure.


2020 ◽  
Vol 19 (1) ◽  
pp. 9-16
Author(s):  
Musayyibi Shuaibu ◽  
Adamu Saidu Abubakar

Renewable energy sources (RES) are being integrated to electrical grid to complement the conventional sources in meeting up with global electrical energy demand. Among the RES, Wind Energy Conversion Systems (WECS) have gained global electricity market competitiveness especially the Doubly Fed Induction Generator (DFIG)-based Wind Turbines (WTs) because of flexible regulation of active and reactive power, higher power quality, variable speed operation, four quadrant converter operation and better dynamic performance. Grid connected DFIG-based WTs are prone to disturbances due to faults in the network which made the utilization of the power generated a major concern. The grid code requirement for integrating the DFIGs to grid specified that they must remain connected and support the grid stability during grid disturbances of up to 1500milliseconds. The ability of the DFIG WT system to uphold to the grid codes requirement is termed the Fault Ride – Through (FRT). This paper presented a 1.5MW grid connected DFIG-based WT model with a Dynamic Voltage Restorer (DVR) for FRT capability enhancement. The design and simulation were performed in MATLAB/Simulink software. The test system was subjected to disturbances leading to Low Voltage Ride – Through (LVRT), Zero Voltage Ride – Through (ZVRT) and High Voltage Ride – Through (HVRT) considering three – phase balanced fault and single line to ground fault. The performance of improved model of DVR shows enhancement over conventional DVR in terms of voltage compensation and fault current mitigation.


Author(s):  
Jamal Abdul-Kareem Mohammed ◽  
Arkan Ahmed Hussein ◽  
Sahar R. Al-Sakini

<p>Power distribution network in Iraq still suffers from significant problems regarding electricity distribution level. The most important problem is the disturbances that are occurring on lines voltages, which in turn, will negatively affect sensitive loads they feed on. Protection of these loads could be achieved efficiently and economically using the dynamic voltage restorer DVR when installed between the voltage source and load to inject required compensation voltage to the network during the disturbances period. The DVR mitigates these disturbances via restoring the load voltage to a pre-fault value within a few milliseconds. To control the DVR work, dq0 transformation concept and PID method with sinusoidal pulse-width modulation SPWM based converter had been used to correct the disturbances and thus enhance the power quality of the distribution network. The DVR performance was tested by MATLAB/Simulink with all kinds of expected voltage disturbances and results investigated the effectiveness of the proposed method.</p>