Alertclu: A Realtime Alert Aggregation and Correlation System

Author(s):  
Tian Zhihong ◽  
Qin Baoshan ◽  
Ye Jianwei ◽  
Zhang Hongli
Keyword(s):  
1976 ◽  
Vol 15 (01) ◽  
pp. 21-28 ◽  
Author(s):  
Carmen A. Scudiero ◽  
Ruth L. Wong

A free text data collection system has been developed at the University of Illinois utilizing single word, syntax free dictionary lookup to process data for retrieval. The source document for the system is the Surgical Pathology Request and Report form. To date 12,653 documents have been entered into the system.The free text data was used to create an IRS (Information Retrieval System) database. A program to interrogate this database has been developed to numerically coded operative procedures. A total of 16,519 procedures records were generated. One and nine tenths percent of the procedures could not be fitted into any procedures category; 6.1% could not be specifically coded, while 92% were coded into specific categories. A system of PL/1 programs has been developed to facilitate manual editing of these records, which can be performed in a reasonable length of time (1 week). This manual check reveals that these 92% were coded with precision = 0.931 and recall = 0.924. Correction of the readily correctable errors could improve these figures to precision = 0.977 and recall = 0.987. Syntax errors were relatively unimportant in the overall coding process, but did introduce significant error in some categories, such as when right-left-bilateral distinction was attempted.The coded file that has been constructed will be used as an input file to a gynecological disease/PAP smear correlation system. The outputs of this system will include retrospective information on the natural history of selected diseases and a patient log providing information to the clinician on patient follow-up.Thus a free text data collection system can be utilized to produce numerically coded files of reasonable accuracy. Further, these files can be used as a source of useful information both for the clinician and for the medical researcher.


1997 ◽  
Vol 51 (6-7) ◽  
pp. 25-27
Author(s):  
V. N. Frankov ◽  
G. Y. Osokin ◽  
O. V. Gavrentiuk ◽  
A. I. Samokhvalov

Measurement ◽  
2021 ◽  
pp. 109867
Author(s):  
Krzysztof ACHTENBERG ◽  
Janusz MIKOŁAJCZYK ◽  
Carmine CIOFI ◽  
Graziella SCANDURRA ◽  
Krystian MICHALCZEWSKI ◽  
...  

2002 ◽  
Vol 10 (1) ◽  
pp. 35 ◽  
Author(s):  
E. Bordenave ◽  
E. Abraham ◽  
G. Jonusauskas ◽  
J. Oberlé ◽  
C. Rullière

2018 ◽  
Vol 196 ◽  
pp. 01032 ◽  
Author(s):  
Andrzej Piotrowski ◽  
Marcin Gajewski ◽  
Cezary Ajdukiewicz

In the presented paper the local instabilities occurring in compression test of perforated thin-walled bars of low slenderness are observed using digital image correlation system ARAMIS. The tested samples slenderness is so low, that from theoretical point of view we are dealing with compression tests of some perforated shells. The samples are made from typical low carbon steel, which has to be treated as elasto-plastic material. Because of that, the final geometry of the sample (after unloading) is also analysed giving a good data for calibration of the theory of elasto-plasticity for large deformations. In analysed cases the total strain values are not exceptionally large, while local rotation (and permanent deformations) have significant values.


Sign in / Sign up

Export Citation Format

Share Document