Opto-electronic system for intravenous infusion monitoring

Author(s):  
Sourabh Suresh Alagundagi ◽  
Krupakar Pasala ◽  
Manish Arora
Author(s):  
E. Rau ◽  
N. Karelin ◽  
V. Dukov ◽  
M. Kolomeytsev ◽  
S. Gavrikov ◽  
...  

There are different methods and devices for the increase of the videosignal information in SEM. For example, with the help of special pure electronic [1] and opto-electronic [2] systems equipotential areas on the specimen surface in SEM were obtained. This report generalizes quantitative universal method for space distribution representation of research specimen parameter by contour equal signal lines. The method is based on principle of comparison of information signal value with the fixed levels.Transformation image system for obtaining equal signal lines maps was developed in two versions:1)In pure electronic system [3] it is necessary to compare signal U (see Fig.1-a), which gives potential distribution on specimen surface along each scanning line with fixed base level signals εifor obtaining quantitative equipotential information on solid state surface. The amplitude analyzer-comparator gives flare sport videopulses at any fixed coordinate and any instant time when initial signal U is equal to one of the base level signals ε.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
Roger Gagnon ◽  
Jason Laberge ◽  
Allison Lamsdale ◽  
Jonathan Histon ◽  
Carl Hudson ◽  
...  

Author(s):  
Tosha B. Wetterneck ◽  
Pascale Carayon ◽  
Folasade Sobande ◽  
Ann Schoofs Hundt

Author(s):  
О. Д. Донець ◽  
В. П. Іщук

The basic results of calculation and research works carried out in the process of creation of power unit of regional passenger airplanes’ family are given. The design features of the propulsion engines and engine of the auxiliary power plant are described. The aforementioned propulsion system includes propulsion engines D-436-148 and engine AI-450-MS of auxiliary power plant. In order to comply with the requirements of Section 4 of the ICAO standard (noise reduction of the aircraft in site), in part of ensuring the noise reduction of engines, when creating the power plant of the An-148/An-158 aircraft family, a single- and double-layer acoustic filler was used in the structure of the engine nacelle and air intake. The use of electronic system for automatic control of propulsion engines such as FADEC and its integration into the digital airborne aircraft complex ensured the operation of engines, included in the power plant provided with high specific fuel consumption, as well as increased the level of automation of the power plant control and monitoring, and ensured aircraft automation landing in ICAO category 3A. In addition, the use of the aforementioned electronic system, allowed to operate the power plant of the aircraft in accordance with technical status. The use of the AI-450-MS auxiliary power plant with an electronic control system such as FADEC, and the drive of the service compressor from a free turbine, eliminated the effect of changes in power and air takeoff, on the deviation of the engine from optimal mode, which also minimized the fuel consumption. The use of fuel metering system TIS-158, allowed to ensure control of its condition and assemblies, without the use of auxiliary devices, built-in control means. In the fire protection system, the use of the electronic control and monitor unit, as well as the use of digital serial code for the exchange of information between the elements of the system and the aircraft systems, has reduced the number of connections, which increased the reliability of the system and reduced its weight characteristics.


2020 ◽  
Vol 1 (30) ◽  
pp. 30-36
Author(s):  
E. A. Krylova ◽  
D. V. Aleinik

The article presents the results of a study of the effectiveness of the use of an inhibitor of pancreatic enzyme secretion of octreotide (Octrade) for the prevention of pancreatitis after endoscopic retrograde cholangiopancreatography (ERCP). It was shown that the administration of Octrade at a dose of 0.3 mg in 500 ml of 0.9 % NaCl by continuous intravenous infusion for 7 hours and then 0.1 mg of Octrade subcutaneously at 6 and 12 hours after the end of intravenous infusion significantly reduced the frequency of pancreatitis (4.0 % and 22.2 %; p < 0.05) and hyperamylasemia (8.0 % and 25.9 %; p < 0.05) after ERCP. It is concluded that Octrade is effective in preventing the development of pancreatitis and hyperamilasemia after ERCP.


Sign in / Sign up

Export Citation Format

Share Document