Usefulness Evaluation of Simulation in Server System Testing

Author(s):  
Jian Sun ◽  
Tomi Mannisto
Keyword(s):  
CHIPSET ◽  
2020 ◽  
Vol 1 (02) ◽  
pp. 61-68
Author(s):  
Anisha Fadia Haya ◽  
Werman kasoep ◽  
Nefy Puteri Novani

This study aims to create a system that can monitor gas cylinders where this device consists of two systems, the first is a system to measure the weight of 3kg LPG gas cylinders to find the remaining gas which will then be displayed on the LCD, and the second the system gives a notification (alarm) if there is a gas leak via SMS. This system consists of Arduino UNO Microcontroller components, Load cell Sensor, MQ-6 Sensor, and SIM800L GSM Module. For overall system testing, the load cell sensor system can display a percentage of the weight value obtained an error rate of 0%, this indicates that the formula used in the program runs according to what is desired. In the MQ-6 sensor system can make the buzzer on at a value >= 700 ppm, the results of the buzzer can live when the detected gas value >= 700 ppm, this is as desired. In the sim800L gsm module system can send leak notifications, the results obtained that the module can send SMS notifications. And the system turns on the buzzer when the LPG gas has reached the minimum limit, the results obtained by the buzzer will sound when the remaining gas value <= 16%. Based on tests conducted on this system the system can measure the desired weight of the cylinder to look for the remaining gas in the form of a percentage and detect a gas leak and then send an SMS notification.


2018 ◽  
Vol 1 (72) ◽  
pp. 63-66 ◽  
Author(s):  
Aleksandr Bukharov ◽  
◽  
Dmitry Baleev ◽  
Maria Ivanova ◽  
Almira Bukharova ◽  
...  
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4089
Author(s):  
Kaiqiang Zhang ◽  
Dongyang Ou ◽  
Congfeng Jiang ◽  
Yeliang Qiu ◽  
Longchuan Yan

In terms of power and energy consumption, DRAMs play a key role in a modern server system as well as processors. Although power-aware scheduling is based on the proportion of energy between DRAM and other components, when running memory-intensive applications, the energy consumption of the whole server system will be significantly affected by the non-energy proportion of DRAM. Furthermore, modern servers usually use NUMA architecture to replace the original SMP architecture to increase its memory bandwidth. It is of great significance to study the energy efficiency of these two different memory architectures. Therefore, in order to explore the power consumption characteristics of servers under memory-intensive workload, this paper evaluates the power consumption and performance of memory-intensive applications in different generations of real rack servers. Through analysis, we find that: (1) Workload intensity and concurrent execution threads affects server power consumption, but a fully utilized memory system may not necessarily bring good energy efficiency indicators. (2) Even if the memory system is not fully utilized, the memory capacity of each processor core has a significant impact on application performance and server power consumption. (3) When running memory-intensive applications, memory utilization is not always a good indicator of server power consumption. (4) The reasonable use of the NUMA architecture will improve the memory energy efficiency significantly. The experimental results show that reasonable use of NUMA architecture can improve memory efficiency by 16% compared with SMP architecture, while unreasonable use of NUMA architecture reduces memory efficiency by 13%. The findings we present in this paper provide useful insights and guidance for system designers and data center operators to help them in energy-efficiency-aware job scheduling and energy conservation.


Sign in / Sign up

Export Citation Format

Share Document