New Synergetic Control of a 20kW Isolated VIENNA Rectifier Front-End EV Battery Charger

Author(s):  
J. Azurza Anderson ◽  
M. Haider ◽  
D. Bortis ◽  
J. W. Kolar ◽  
M. Kasper ◽  
...  
Electronics ◽  
2021 ◽  
Vol 10 (17) ◽  
pp. 2069
Author(s):  
Panteleimon Papamanolis ◽  
Dominik Bortis ◽  
Florian Krismer ◽  
David Menzi ◽  
Johann Walter Kolar

A new universal front-end PFC rectifier topology of a battery charger for Electric Vehicles (EVs) is proposed, which allows fast charging at rated and/or full power level in case of 3-phase (Europe) as well as 1-phase (USA) mains supply. In this regard, a conventional 3-phase PFC rectifier would facilitate only one-third of the rated power in case of 1-phase operation. The new topology is based on a two-level six-switch (2LB6) 3-phase boost-type PFC rectifier, which is extended with a diode bridge-leg and additional windings of the Common-Mode (CM) chokes of the EMI filter. Besides this extension of the power circuit, the general design of the new converter is explained, and the generated Differential Mode (DM) and Common Mode (CM) EMI disturbances are investigated for 3-phase and 1-phase operation, resulting in guidelines for the EMI filter design. The EMI performance (CISPR 11 class-B QP) is experimentally verified for 1-phase and 3-phase operation at an output power of 4.5 kW, using a full-scale hardware prototype that implements the proposed extensions for a 2LB6 3-phase boost-type PFC rectifier and that is designed for output power levels of 22 kW and 19 kW in case of 3-phase and 1-phase operation, respectively. Compared to a conventional 2LB6 PFC rectifier, the volume of the extended system increases from 2.7 dm3 to 3.4 dm3, of which 0.5 dm3 is due to the additional dc-link capacitance for buffering the power pulsation with twice the mains frequency occurring for 1-phase operation.


Author(s):  
K. Srinivasan ◽  
S. Vijayan ◽  
S. Paramasivam ◽  
K. Sundaramoorthi

This paper presents the power quality improvements for a BLDC driver using Vienna rectifier as front end converter. The major drawbacks in the BLDC motor drive and non linear load applications are the line pollution and depreciation of the power factor. The conventional power factor correction method is not economical and efficient. It requires bulky components as load changes and produce high THD and less Power factor. The front end converter of BLDC bridge inverter drive is proposed by the Vienna rectifier, which can contribute more significantly in improving the power factor and reduce the line pollution. The Vienna rectifier topology is controlled by the constant switching frequency control technique for wide range of load variation and it reduces the THD, improve the power factor and provide a steady DC link voltage to the bridge inverter to drive the BLDC motor. The design calculation and performance characteristics of BLDC motor and Vienna rectifier are verified by using Matlab simulation.


Sign in / Sign up

Export Citation Format

Share Document