Determination of Oxygen Saturation Based on Distorted Photoplethysmography Signals by Scaling Method

Author(s):  
Adam Naguszewski ◽  
Jerzy Weremczuk
1955 ◽  
Vol 217 (1) ◽  
pp. 479-488
Author(s):  
Makepeace U. Tsao ◽  
Shirley S. Sethna ◽  
Charles H. Sloan ◽  
Lillian J. Wyngarden

2000 ◽  
Author(s):  
Ralph J. F. Houston ◽  
Jan Menssen ◽  
Marco C. van der Sluijs ◽  
Willy N. Colier ◽  
Berend Oeseburg

1987 ◽  
Vol 252 (5) ◽  
pp. H1031-H1040 ◽  
Author(s):  
M. L. Ellsworth ◽  
R. N. Pittman ◽  
C. G. Ellis

We present a computer-aided videodensitometric method for the determination of oxygen saturation in red blood cells flowing through capillaries of the hamster cheek pouch retractor muscle. The optical density (OD) of red blood cells is determined at two wavelengths. At the first, 431 nm, there is a maximum difference between absorption by oxygen deoxyhemoglobin. At the second, 420 nm, absorption is equal for the two absorbing species (isosbestic wavelength). In capillaries of the retractor muscle a relationship between oxygen saturation (S) and the following OD ratio was obtained as S = -1.71 (OD431/OD420) + 2.20. The error (95% confidence interval) in oxygen saturation associated with a determination of the OD ratio is estimated to be +/- 4.8%. The computerization of the method employs a frame-by-frame analysis of the light intensity over a selected capillary segment. The light intensity waveform along the segment is digitized and the minimum (I) and maximum (I0) light intensities are used to compute an optical density (OD = log10 [I0/I]). These minimum and maximum intensities correspond to the presence and absence of a red blood cell, respectively. The method permits the off-line analysis of videotaped scenes and provides a means of assessing the extent of temporal and spatial heterogeneity of oxygen saturation in selected capillary networks. The method has been developed for use in capillaries in transilluminated striated muscle but should be generally applicable to the measurement of capillary oxygen saturation in other tissues.


2016 ◽  
Vol 5 (2) ◽  
pp. 281-288 ◽  
Author(s):  
Panagiotis P. Zacharias ◽  
Elpida G. Chatzineofytou ◽  
Sotirios T. Spantideas ◽  
Christos N. Capsalis

Abstract. In the present work, the determination of the magnetic behavior of localized magnetic sources from near-field measurements is examined. The distance power law of the magnetic field fall-off is used in various cases to accurately predict the magnetic signature of an equipment under test (EUT) consisting of multiple alternating current (AC) magnetic sources. Therefore, parameters concerning the location of the observation points (magnetometers) are studied towards this scope. The results clearly show that these parameters are independent of the EUT's size and layout. Additionally, the techniques developed in the present study enable the placing of the magnetometers close to the EUT, thus achieving high signal-to-noise ratio (SNR). Finally, the proposed method is verified by real measurements, using a mobile phone as an EUT.


Blood ◽  
1987 ◽  
Vol 69 (1) ◽  
pp. 316-323 ◽  
Author(s):  
MP Sorette ◽  
MG Lavenant ◽  
MR Clark

Abstract In an effort to study the rheologic effects of small amounts of hemoglobin S (HbS) polymer in sickle red cells, we have used the ektacytometer, a laser diffraction couette viscometer, to measure sickle cell deformability as a function of oxygen tension. Sickle cell populations of defined intracellular hemoglobin concentration (MCHC) were isolated using Stractan density gradients and were resuspended in buffered polyvinylpyrrolidone solutions for deformability measurements. Using a gas-porous, hollow fiber gas exchange system to establish a linear gradient in oxygen tension, deformability was measured over a pO2 range of 76 to 0 mm Hg. Parallel spectroscopic determinations of oxygen saturation permitted determination of cell deformability as a function of oxygen saturation for each discrete MCHC population. From these measurements the level of oxygen saturation at which a loss in cell deformability was first detected could be defined. Then, using the data of Noguchi and Schecter, the amount of polymerized HbS in the cells at that defined level of oxygen saturation was estimated. The results of this analysis suggested that the quantity of polymer that caused a detectable loss in cell deformability increased with increasing MCHC. In addition, for MCHC above 30 g/dL, this represented a substantial fraction of the total HbS in the cell.


Sign in / Sign up

Export Citation Format

Share Document