Research on energy saving control of chilled water system of central air conditioning system

Author(s):  
Li Zhuang Ju ◽  
Lv Cai ◽  
Mei Jie
2012 ◽  
Vol 204-208 ◽  
pp. 4280-4285 ◽  
Author(s):  
Jian Min Sun ◽  
Chun Dong Zhang ◽  
Ze Yang Zhou

Considering the central air conditioning system is highly susceptible to interferences from external environment, this paper established a dynamic mathematical model for chilled water system with the air conditioning area, fan coil unit and air conditioning area interference factors. Selection of chilled water system as a controlled object, designed the energy saving control system for central air-conditioning. The inputs of PID controller are deviation of actual temperature and setting temperature, and the change rate of the deviation; output is operation frequency of pump. Experiment shows that, PID control system in 90% time operating at a frequency of 10Hz-40Hz, average is 32.5Hz. Compared with no control system, the pump power consumption was reduced 33.9%.In conclusion, PID control in the central air conditioning system have a good energy saving effect.


2019 ◽  
Vol 2019 ◽  
pp. 1-12
Author(s):  
Yan Zhang ◽  
Xiaoli Chu ◽  
Yang Liu ◽  
Yongqiang Liu

The chilled water system of central air conditioning is a typical hybrid system. The dynamic adjustment of cooling capacity based on hybrid system can achieve accurate temperature control and real-time energy saving. Mixed logical dynamical (MLD) systems have advantage for solving constrained optimization problems of this type of case by numerical methods. This paper proposes a novel modified type of MLD system, which enhances the model applicability and improves the switching flexibility and control effect for the framework. In order to meet the needs of cooling capacity and energy saving, the optimal control problem is transformed as MIQP problem by defined performance index. As a numeral example of application, the model and control method is used in pumps group control for variable water volume in chilled water system of central air conditioning. At last, the dynamic and energy-saving effects of the system are simulated, which shows the ideal control results.


2012 ◽  
Vol 516-517 ◽  
pp. 1224-1228
Author(s):  
Na Liang ◽  
Rui Li

Due to energy reserves reduces gradually and uneven distribution, all countries pay more and more attention to energy saving and improve the effective utilization of energy, China also attaches great important to this. Energy saving of buildings is a necessary development trend. Air conditioning system as a large important part of building energy consumption has a huge energy-saving potential. This article mainly introduced the related strategies of energy saving in central air conditioning water system from the following three points of view: the water treatment, the cooling tower, and the variable frequency pump.


2012 ◽  
Vol 610-613 ◽  
pp. 2478-2482
Author(s):  
Yang Cui ◽  
Lei Huang

As the scale of the air conditioning system is constantly increasing, some problems still exist and remain to be solved in the chilled water system. Among them, the leading problems lie in the insufficient research of the overall character on the user side and lack of simulation analysis. Corresponding calculating procedures are mixed programmed using VB and FORTRAN language to conduct to simulating analysis, to testify reliability and feasibility of the method.


2014 ◽  
Vol 1039 ◽  
pp. 409-414
Author(s):  
Tao Han ◽  
Xue Feng Lai ◽  
Liang Wen Yan ◽  
Zai Feng Zhang

This paper introduces the components of central air-conditioning system and compares the advantages and disadvantages of the PID control and fuzzy control.Fuzzy control theory and inverter technology are combined to design the Energy-Saving Monitoring System based on the fuzzy control box of STM32F103C8T6,Siemens S7-200 PLC, ABB inverter as the hardware system and interfaces configuration of KingView as the software. Experimental results show that the water system can be variable flow controlled based on the dynamic load, central air-conditioning energy efficiency the COP has greatly improved under the premise of ensuring the comfort of central air-conditioning.


2011 ◽  
Vol 250-253 ◽  
pp. 2695-2699 ◽  
Author(s):  
De Bao Lei ◽  
Zhong Hua Tang ◽  
Kai Zhao

With the application of the central air conditioning system widely, it has increased fast the consumption of national energy. This paper analyzes how to control a central air-conditioning system for energy saving, mainly including control characteristics , automatic control component and the control approaches of energy saving. Energy-saving approaches consist of indoor state parameter selection control, variable-speed pump control,variable air volume system control, Storage cold control and control Optimization.


2012 ◽  
Vol 170-173 ◽  
pp. 2564-2567
Author(s):  
Huai Ming Ning ◽  
Guo Feng

Heating and Air Condition, Pipe Network, VB,FORTRAN,Mixed Programming Abstract:As the scale of the air conditioning system is constantly increasing, some problems still exist and remain to be solved in the chilled water system. Among them, the leading problems lie in the insufficient research of the overall character on the user side and lack of simualtion analysis. Corresponding calculating procedures are Mixed programmed using VB and FORTRAN language to conduct to simulating analysis, to testify reliability and feasibility of the method.