Flow patterns and shear stress investigation and in vitro studies of blood pump

Author(s):  
Fangqun Wang ◽  
Qinlin Wu ◽  
Teng Jing ◽  
Linlin Liu ◽  
Kunxi Qian
2021 ◽  
pp. 039139882110416
Author(s):  
Ge He ◽  
Jiafeng Zhang ◽  
Aakash Shah ◽  
Zachary B Berk ◽  
Lu Han ◽  
...  

Blood pumps have been increasingly used in mechanically assisted circulation for ventricular assistance and extracorporeal membrane oxygenation support or during cardiopulmonary bypass for cardiac surgery. However, there have always been common complications such as thrombosis, hemolysis, bleeding, and infection associated with current blood pumps in patients. The development of more biocompatible blood pumps still prevails during the past decades. As one of those newly developed pumps, the Breethe pump is a novel extracorporeal centrifugal blood pump with a hybrid magnetic and mechanical bearing with attempt to reduce device-induced blood trauma. To characterize the hydrodynamic and hemolytic performances of this novel pump and demonstrate its superior biocompatibility, we use a combined computational and experimental approach to compare the Breethe pump with the CentriMag and Rotaflow pumps in terms of flow features and hemolysis under an operating condition relevant to ECMO support (flow: 5 L/min, pressure head: ~350 mmHg). The computational results showed that the Breethe pump has a smaller area-averaged wall shear stress (WSS), a smaller volume with a scalar shear stress (SSS) level greater than 100 Pa and a lower device-generated hemolysis index compared to the CentriMag and Rotaflow pumps. The comparison of the calculated residence times among the three pumps indicated that the Breethe pump might have better washout. The experimental data from the in vitro hemolysis testing demonstrated that the Breethe pump has the lowest normalized hemolysis index (NIH) than the CentriMag and Rotaflow pumps. It can be concluded based on both the computational and experimental data that the Breethe pump is a viable pump for clinical use and it has better biocompatibility compared to the clinically accepted pumps.


2019 ◽  
Vol 42 (4) ◽  
pp. 182-189 ◽  
Author(s):  
Guang-Mao Liu ◽  
Dong-Hai Jin ◽  
Hai-bo Chen ◽  
Jian-feng Hou ◽  
Yan Zhang ◽  
...  

Adverse events caused by flow-induced thrombus formation around the bearing/shaft of an axial blood pump remain a serious problem for axial blood pumps. Moreover, excessive anticoagulation with thrombosis around the bearing potentially increases the risk of postoperative gastrointestinal bleeding. The purpose of this study is to analyze the influence of the bearing structure on the thrombosis potential of an axial blood pump. The bearing/shaft structure was embedded into an axial blood pump numerical model. The numerical simulation and analysis are focused on the low wall shear stresses, recirculation, and residence time close to the bearing region to evaluate the potential for thrombosis around the bearing. Then, the flow field near the blood pump bearing was tested via in vitro particle image velocimetry experiments to verify the numerical results. The simulation results showed that after embedding the bearing/shaft structure a recirculation zone appeared in the outlet guide vane bearing/shaft region, the residence time increased 11-fold in comparison to the pump without the bearing/shaft structure, the scalar shear stress in the shaft surface was less than 7.8 Pa, and the stress accumulation was less than 0.10 Pa s. The numerical results showed that platelets that flow through the bearing region are exposed to significantly lower wall shear stress and a longer residence time, leading to activated platelet adhesion. The reduced stress accumulation and increased time in the bearing region lead to increased platelet activation.


2006 ◽  
Vol 15 (04) ◽  
pp. 245-257 ◽  
Author(s):  
H. J. Rolf ◽  
K. G. Wiese ◽  
H. Siggelkow ◽  
H. Schliephake ◽  
G. A. Bubernik

1998 ◽  
Vol 80 (09) ◽  
pp. 437-442 ◽  
Author(s):  
I. Hioki ◽  
K. Onoda ◽  
T. Shimono ◽  
H. Shimpo ◽  
K. Tanaka ◽  
...  

SummaryAlterations in platelet aggregability may play a role in the pathogenesis of qualitative platelet defects associated with cardiopulmonary bypass (CPB). We circulated fresh heparinized whole blood through tubing sets coated with heparin (C group, n = 10) and through non-coated sets (N group, n = 10) as a simulated CPB circuit. Shear stress (108 dyne/cm2)-induced platelet aggregation (hSIPA), plasma von Willebrand factor (vWF) activity and platelet glycoprotein (GP) Ib expression were measured, before, during, and after this in vitro set up of circulation. In the two groups, the extent of hSIPA significantly decreased during circulation and was partially restored after circulation. Decreases in the extent of hSIPA were significantly less with use of heparin-coated circuits. There was an equivalent reduction in plasma vWF activity, in the two groups. Expression of platelet surface GP Ib decreased significantly during circulation and recovered after circulation. Reduction of surface GP Ib expression during circulation was significantly less in the C group than that in the N group. Decrease in surface GP Ib expression correlated (r = 0.88 in either group) with the magnitude of hSIPA, in the two groups. The progressive removal of surface GP Ib was mainly attributed to redistribution of GP Ib from the membrane skeleton into the cytoskeleton. Our observations suggest that use of heparin-coated circuits partly blocks the reduction of hSIPA, as a result of a lesser degree of redistribution of GP Ib.


1968 ◽  
Vol 19 (03/04) ◽  
pp. 584-592 ◽  
Author(s):  
Hanna Lukasiewicz ◽  
S Niewiarowski

Summary and Conclusion1. It has been found that EACA does not inhibit activation of human plasminogen into plasmin by SK and UK in a concentration of 5 × 10–2 M. The activation of bovine plasminogen by SK and UK is inhibited by this concentration of EACA but not by a lower one.2. EACA in concentrations of 1,5 × 10–1 – 10–4 M does not inhibit casein proteolysis by plasmin. The proteolysis of fibrinogen and fibrin measured by the release of TCA soluble tyrosine is inhibited by EACA in concentrations of 1,5 × 10–1 – 10–2 M.3. The lysis of non-stabilized clots by plasmin measured in a test tube was inhibited by an EACA concentration of 5 × 10–3 – 5 × 10–4 M. The lysis of stabilized clots by plasmin was inhibited by an EACA concentration of 10–5 M.4. On the basis of experimental findings and data given in literature the authors postulate that the mechanism of the antifibrinolytic effects of EACA consists mainly in a modification of plasmin action on fibrin. These effects are dependent on the structure of the fibrin clots.


1969 ◽  
Vol 21 (02) ◽  
pp. 234-244 ◽  
Author(s):  
N Mackay ◽  
J.C Ferguson ◽  
Antonia Bagshawe ◽  
A.T.T Forrester ◽  
G.P Mcnicol
Keyword(s):  

SummaryAn account is given of the effects of boomslang venom in man. Evidence was found of a fibrinolytic state apparently secondary to the coagulant action of the venom. These features rapidly responded to the administration of specific antivenom. In vitro studies, using a homogenate of boomslang parotids, confirmed the coagulant properties of the venom and showed them to be of much greater potency than the proteolytic actions.