Are Size Measures Better Than Expert Judgment? An Industrial Case Study on Requirements Volatility

Author(s):  
Annabella Loconsole ◽  
Jurgen Borstler
2006 ◽  
Vol 19 (2) ◽  
pp. 247-260 ◽  
Author(s):  
Peter Korosec ◽  
Jurij Silc

The Multilevel Ant Stigmergy Algorithm (MASA) is a new approach to solving multi-parameter problems based on stigmergy, a type of collective work that can be observed in nature. In this paper we evaluate the performance of MASA regarding its applicability as numerical optimization techniques. The evaluation is performed with several widely used benchmarks functions, as well as on an industrial case study. We also compare the MASA with Differential Evolution, well-known numerical optimization algorithm. The average solution obtained with the MASA was better than a solution recently found using Differential Evolution.


2005 ◽  
Vol 51 (12) ◽  
pp. 325-329 ◽  
Author(s):  
X. Wang ◽  
X. Bai ◽  
J. Qiu ◽  
B. Wang

The performance of a pond–constructed wetland system in the treatment of municipal wastewater in Kiaochow city was studied; and comparison with oxidation ponds system was conducted. In the post-constructed wetland, the removal of COD, TN and TP is 24%, 58.5% and 24.8% respectively. The treated effluent from the constructed wetland can meet the Chinese National Agricultural and Irrigation Standard. The comparison between pond–constructed wetland system and oxidation pond system shows that total nitrogen removal in a constructed wetland is better than that in an oxidation pond and the TP removal is inferior. A possible reason is the low dissolved oxygen concentration in the wetland. Constructed wetlands can restrain the growth of algae effectively, and can produce obvious ecological and economical benefits.


2021 ◽  
Vol 26 (4) ◽  
Author(s):  
Alvaro Veizaga ◽  
Mauricio Alferez ◽  
Damiano Torre ◽  
Mehrdad Sabetzadeh ◽  
Lionel Briand

AbstractNatural language (NL) is pervasive in software requirements specifications (SRSs). However, despite its popularity and widespread use, NL is highly prone to quality issues such as vagueness, ambiguity, and incompleteness. Controlled natural languages (CNLs) have been proposed as a way to prevent quality problems in requirements documents, while maintaining the flexibility to write and communicate requirements in an intuitive and universally understood manner. In collaboration with an industrial partner from the financial domain, we systematically develop and evaluate a CNL, named Rimay, intended at helping analysts write functional requirements. We rely on Grounded Theory for building Rimay and follow well-known guidelines for conducting and reporting industrial case study research. Our main contributions are: (1) a qualitative methodology to systematically define a CNL for functional requirements; this methodology is intended to be general for use across information-system domains, (2) a CNL grammar to represent functional requirements; this grammar is derived from our experience in the financial domain, but should be applicable, possibly with adaptations, to other information-system domains, and (3) an empirical evaluation of our CNL (Rimay) through an industrial case study. Our contributions draw on 15 representative SRSs, collectively containing 3215 NL requirements statements from the financial domain. Our evaluation shows that Rimay is expressive enough to capture, on average, 88% (405 out of 460) of the NL requirements statements in four previously unseen SRSs from the financial domain.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4118
Author(s):  
I Made Yulistya Negara ◽  
Daniar Fahmi ◽  
Dimas Anton Asfani ◽  
IGN Satriyadi Hernanda ◽  
Rendi Bagus Pratama ◽  
...  

In this study, the lightning protection system and grounding system of one plant of the petrochemical industry were investigated, evaluated, and improved. The methods used in this study were rolling sphere and angle protection methods. The grounding system of the building under study was modeled and simulated using ATP/EMTP (Alternative Transient Program/Electromagnetic Transient Program) software. The results show that the external lightning protection system of the prilling tower studied does not adhere to IEC 62305 and IEC 1024-1-1 standards. Moreover, the grounding configuration of the DCS building was not appropriate for protecting sensitive equipment inside. Lightning causes an enormous potential difference between lightning ground rods in the grounding system. Additionally, disabling the existing surge protective device (SPD) causes an increase in the magnitude of Ground Potential Rise at the DCS building. Improvement of the lightning protection system of the prilling tower and DCS building on Plant 1 of this petrochemical company as well as some other recommendations for improvements are proposed. This paper also shows evidence that external lightning protection, internal lightning protection, and the grounding system need to be connected to make an exemplary lightning protection system.


Sign in / Sign up

Export Citation Format

Share Document