Real ECG signal acquisition with shimmer platform and using of compressed sensing techniques in the offline signal reconstruction

Author(s):  
Oussama Kerdjidj ◽  
Khalida Ghanem ◽  
Abbes Amira ◽  
Farid Harizi ◽  
Fatima Chouireb
Author(s):  
Mei Sun ◽  
Jinxu Tao ◽  
Zhongfu Ye ◽  
Bensheng Qiu ◽  
Jinzhang Xu ◽  
...  

Background: In order to overcome the limitation of long scanning time, compressive sensing (CS) technology exploits the sparsity of image in some transform domain to reduce the amount of acquired data. Therefore, CS has been widely used in magnetic resonance imaging (MRI) reconstruction. </P><P> Discussion: Blind compressed sensing enables to recover the image successfully from highly under- sampled measurements, because of the data-driven adaption of the unknown transform basis priori. Moreover, analysis-based blind compressed sensing often leads to more efficient signal reconstruction with less time than synthesis-based blind compressed sensing. Recently, some experiments have shown that nonlocal low-rank property has the ability to preserve the details of the image for MRI reconstruction. Methods: Here, we focus on analysis-based blind compressed sensing, and combine it with additional nonlocal low-rank constraint to achieve better MR images from fewer measurements. Instead of nuclear norm, we exploit non-convex Schatten p-functionals for the rank approximation. </P><P> Results & Conclusion: Simulation results indicate that the proposed approach performs better than the previous state-of-the-art algorithms.


2016 ◽  
Vol 2016 ◽  
pp. 1-16 ◽  
Author(s):  
Irena Orović ◽  
Vladan Papić ◽  
Cornel Ioana ◽  
Xiumei Li ◽  
Srdjan Stanković

Compressive sensing has emerged as an area that opens new perspectives in signal acquisition and processing. It appears as an alternative to the traditional sampling theory, endeavoring to reduce the required number of samples for successful signal reconstruction. In practice, compressive sensing aims to provide saving in sensing resources, transmission, and storage capacities and to facilitate signal processing in the circumstances when certain data are unavailable. To that end, compressive sensing relies on the mathematical algorithms solving the problem of data reconstruction from a greatly reduced number of measurements by exploring the properties of sparsity and incoherence. Therefore, this concept includes the optimization procedures aiming to provide the sparsest solution in a suitable representation domain. This work, therefore, offers a survey of the compressive sensing idea and prerequisites, together with the commonly used reconstruction methods. Moreover, the compressive sensing problem formulation is considered in signal processing applications assuming some of the commonly used transformation domains, namely, the Fourier transform domain, the polynomial Fourier transform domain, Hermite transform domain, and combined time-frequency domain.


Sensors ◽  
2018 ◽  
Vol 18 (10) ◽  
pp. 3373 ◽  
Author(s):  
Ziran Wei ◽  
Jianlin Zhang ◽  
Zhiyong Xu ◽  
Yongmei Huang ◽  
Yong Liu ◽  
...  

In the reconstruction of sparse signals in compressed sensing, the reconstruction algorithm is required to reconstruct the sparsest form of signal. In order to minimize the objective function, minimal norm algorithm and greedy pursuit algorithm are most commonly used. The minimum L1 norm algorithm has very high reconstruction accuracy, but this convex optimization algorithm cannot get the sparsest signal like the minimum L0 norm algorithm. However, because the L0 norm method is a non-convex problem, it is difficult to get the global optimal solution and the amount of calculation required is huge. In this paper, a new algorithm is proposed to approximate the smooth L0 norm from the approximate L2 norm. First we set up an approximation function model of the sparse term, then the minimum value of the objective function is solved by the gradient projection, and the weight of the function model of the sparse term in the objective function is adjusted adaptively by the reconstruction error value to reconstruct the sparse signal more accurately. Compared with the pseudo inverse of L2 norm and the L1 norm algorithm, this new algorithm has a lower reconstruction error in one-dimensional sparse signal reconstruction. In simulation experiments of two-dimensional image signal reconstruction, the new algorithm has shorter image reconstruction time and higher image reconstruction accuracy compared with the usually used greedy algorithm and the minimum norm algorithm.


2013 ◽  
Vol 462-463 ◽  
pp. 1001-1004
Author(s):  
Xue Wang ◽  
Wen Liang Niu ◽  
Yuan Sheng Liu

In order to more accurate detection of ECG signal and cost savings, this paper designed a set of ECG signal acquisition system based on Matlab. The system is composed of hardware and software. Hardware is made up of signal acquisition processing circuit and MPC82G516 microcontroller for AD conversion. The software mainly contains configuring Matlab serial to realize communication with MPC82G516 and uses abundant filter resources of Matlab to remove noise by differential, absolute value, smoothing and threshold selection algorithm of R wave detection, R wave peak provides the basis for calculating the heart rate. This paper uses Matlab friendly user interface for displaying received data to make the data more intuitive and read more easily.


2015 ◽  
Vol 22 (10) ◽  
pp. 1743-1747 ◽  
Author(s):  
Valerio Cambareri ◽  
Mauro Mangia ◽  
Fabio Pareschi ◽  
Riccardo Rovatti ◽  
Gianluca Setti

Sensors ◽  
2018 ◽  
Vol 18 (9) ◽  
pp. 2835 ◽  
Author(s):  
Zhongjie Hou ◽  
Jinxi Xiang ◽  
Yonggui Dong ◽  
Xiaohui Xue ◽  
Hao Xiong ◽  
...  

A prototype of an electrocardiogram (ECG) signal acquisition system with multiple unipolar capacitively coupled electrodes is designed and experimentally tested. Capacitively coupled electrodes made of a standard printed circuit board (PCB) are used as the sensing electrodes. Different from the conventional measurement schematics, where one single lead ECG signal is acquired from a pair of sensing electrodes, the sensing electrodes in our approaches operate in a unipolar mode, i.e., the biopotential signals picked up by each sensing electrodes are amplified and sampled separately. Four unipolar electrodes are mounted on the backrest of a regular chair and therefore four channel of signals containing ECG information are sampled and processed. It is found that the qualities of ECG signal contained in the four channel are different from each other. In order to pick up the ECG signal, an index for quality evaluation, as well as for aggregation of multiple signals, is proposed based on phase space reconstruction. Experimental tests are carried out while subjects sitting on the chair and clothed. The results indicate that the ECG signals can be reliably obtained in such a unipolar way.


Sign in / Sign up

Export Citation Format

Share Document