Medium voltage distribution network traveling wave fault location method based on wavelet packet energy spectrum

Author(s):  
HaiFeng Zhao ◽  
YuLin Qi ◽  
HuiBin Jia
Author(s):  
Congshan Li ◽  
Ping He ◽  
Feng Wang ◽  
Cunxiang Yang ◽  
Yukun Tao ◽  
...  

Background: A novel fault location method of HVDC transmission line based on a concentric relaxation principle is proposed in this paper. Methods: Due to the different position of fault, the instantaneous energy measured from rectifier and inverter are different, and the ratio k between them is the relationship to the fault location d. Through the analysis of amplitude-frequency characteristics, we found that the wave attenuation characteristic of low frequency in the traveling wave is stable, and the amplitude of energy is larger, so we get the instantaneous energy ratio by using the low-frequency data. By using the method of wavelet packet decomposition, the voltage traveling wave signal was decomposed. Results: Finally, calculate the value k. By using the data fitting, the relative function of k and d can be got, that is the fault location function. Conclusion: After an exhaustive evaluation process considering different fault locations, fault resistances, and noise on the unipolar DC transmission system, four-machine two-area AC/DC parallel system, and an actual complex grid, the method presented here showed a very accurate and robust behavior.


2020 ◽  
Vol 35 (4) ◽  
pp. 1987-1998 ◽  
Author(s):  
Liwei Xie ◽  
Longfu Luo ◽  
Yong Li ◽  
Yu Zhang ◽  
Yijia Cao

Author(s):  
N. S. B. Jamili ◽  
M. R. Adzman ◽  
S. R. A. Rahim ◽  
S. M. Zali ◽  
M. Isa ◽  
...  

This paper focused on studying an algorithm of earth fault location in the medium voltage distribution network. In power system network, most of the earth fault occurs is a single line to ground fault. A medium voltage distribution network with resistance earthing at the main substation and an earth fault attached along the distribution network is modeled in ATP Draw. The generated earth fault is simulated, and the voltage and current signal produced is recorded. The earth fault location algorithm is simulated and tested in MATLAB. The accuracy of the earth fault location algorithm is tested at several locations and fault resistances. A possible correction technique is explained to minimize the error. The results show an improvement fault location distance estimation with minimum error.


2019 ◽  
Vol 19 (2) ◽  
pp. 28-34 ◽  
Author(s):  
Majid Dashtdar ◽  
Masoud Dashtdar

AbstractOne of the most important issues in employing distribution networks is detecting the fault location in medium-voltage distribution feeders. Due to the vastness of distribution networks and growing distributed generation (DG) sources in this network, detection is difficult with the common methods. The aim of this paper is to present a method based on voltage distributed meters in a medium-voltage distribution network (by smart meters installed along the feeder) in order to detect the fault location in the presence of DG sources. Due to vastness of distribution network and cost of installing smart meters, it is not economically possible to install meters in all the Buses of the network. That’s why in this article, combination of genetic and locating algorithms and fault-based on voltage drop has been used to suggest a method to optimize the meter locations. In order to evaluate the efficiency of the method suggested, first we determine the optimal number and location of the meters and then we apply the fault that has been simulated in different Buses of the sample network, using PSCAD/EMTDC software. After results analysis, the fault location is estimated by MATLAB. Simulation results show that the fault locating method by optimal number of meters has good efficiency and accuracy in detecting faults in different spots and in different resistance ranges.