Broad-band elliptical beamshape horns with low cross polarization

1990 ◽  
Vol 38 (6) ◽  
pp. 800-805 ◽  
Author(s):  
E. Lier
2011 ◽  
Vol 2011 ◽  
pp. 1-11 ◽  
Author(s):  
Grzegorz Adamiuk ◽  
Mario Pauli ◽  
Thomas Zwick

A concept of an array configuration for an ultrawideband suppression of the cross-polarization is presented. The method is explained in detail, and a mathematical description of the principle is given. It is shown that the presented configuration is convenient for the development of very broad band, dual-orthogonal, linearly polarized antennas with high polarization purity. The investigated configuration shows a high decoupling of the orthogonal ports and is capable for antennas with a main beam direction perpendicular to the substrate surface, that is, for a planar design. The phase center of the antenna configuration remains fixed at one single point over the complete desired frequency range, allowing a minimum dispersion of the radiated signal. The influence of nonidealities in the feeding network on the polarization purity is investigated. The presented method introduces a superior possibility of an extension of typical UWB technique to fully polarized systems, which improves significantly performance in, for example, UWB-MIMO or UWB-Radar.


Author(s):  
Burton B. Silver ◽  
Theodore Lawwill

Dutch-belted 1 to 2.5 kg anesthetized rabbits were exposed to either xenon or argon laser light administered in a broad band, designed to cover large areas of the retina. For laser exposure, the pupil was dilated with atropine sulfate 1% and pheny lephrine 10%. All of the laser generated power was within a band centered at 5145.0 Anstroms. Established threshold for 4 hour exposures to laser irradiation are in the order of 25-35 microwatts/cm2. Animals examined for ultrastructural changes received 4 hour threshold doses. These animals exhibited ERG, opthalmascopic, and histological changes consistent with threshold damage.One month following exposure the rabbits were killed with pentobarbitol. The eyes were immediately enucleated and dissected while bathed in 3% phosphate buffered gluteraldehyde.


1984 ◽  
Vol 15 (4) ◽  
pp. 289-294
Author(s):  
Martin S. Robinette ◽  
Robert H. Brey

A transformer mixing network is described which allows the calibration of broad-band masking for portable audiometers that lack a built-in mixing network. For many instruments the transformer network is preferable to the resistive network previously published.


1964 ◽  
Vol 12 (01) ◽  
pp. 126-136 ◽  
Author(s):  
Karl H. Slotta ◽  
J. D Gonzalez

SummaryWhen urea or ε-amino caproic acid were used as solublizing agents for plasminogen in electrophoretic experiments, only one broad band of the proenzyme was obtained on acetate cellulose, in starch block, and in acrylamide gel. In starch gel electrophoresis, however, both forms of plasminogen – the native or euglobulin and Kline’s or Pseudoglobulin plasminogen – separated into six bands. These migrated toward the cathode at room temperature in borate or veronal buffer in the alkaline range and showed full activity in fibrinagar-streptokinase plates.


Sign in / Sign up

Export Citation Format

Share Document