Quantitative heat transfer measurements in hypersonic wind tunnels by means of infrared thermography

1993 ◽  
Vol 29 (3) ◽  
pp. 878-893 ◽  
Author(s):  
G. Simeonides ◽  
J.-P. Vermeulen ◽  
H.L. Boerrigter ◽  
J.F. Wendt
2011 ◽  
Vol 134 (1) ◽  
Author(s):  
Shyy Woei Chang ◽  
Tong-Miin. Liou ◽  
Wei-Chun Chen

Detailed heat transfer distributions over two opposite leading and trailing walls roughened by hemispherical protrusions were measured from a rotating rectangular channel at rotation number up to 0.6 to examine the effects of Reynolds (Re), rotation (Ro), and buoyancy (Bu) numbers on local and area-averaged Nusselt numbers (Nu and Nu¯) using the infrared thermography. A set of selected heat transfer data illustrates the Coriolis and rotating buoyancy effects on the detailed Nu distributions and the area-averaged heat transfer performances of the rotating channel. The Nu¯ for the developed flow region on the leading and trailing walls are parametrically analyzed to devise the empirical heat transfer correlations that permit the evaluation of the interdependent and individual Re, Ro, and Bu effect on Nu¯.


Author(s):  
Christian Egger ◽  
Jens von Wolfersdorf ◽  
Martin Schnieder

In this paper a transient method for measuring heat transfer coefficients in internal cooling systems using infrared thermography is applied. The experiments are performed with a two-pass internal cooling channel connected by a 180° bend. The leading edge and the trailing edge consist of trapezoidal and nearly rectangular cross sections, respectively, to achieve an engine-similar configuration. Within the channels rib arrangements are considered for heat transfer enhancement. The test model is made of metallic material. During the experiment the cooling channels are heated by the internal flow. The surface temperature response of the cooling channel walls is measured on the outer surface by infrared thermography. Additionally, fluid temperatures as well as fluid and solid properties are determined for the data analysis. The method for determining the distribution of internal heat transfer coefficients is based on a lumped capacitance approach which considers lateral conduction in the cooling system walls as well as natural convection and radiation heat transfer on the outer surface. Because of time-dependent effects a sensitivity analysis is performed to identify optimal time periods for data analysis. Results are compared with available literature data.


Sign in / Sign up

Export Citation Format

Share Document