Development of new concept optical zero-sequence current/voltage transducers for distribution network

1991 ◽  
Vol 6 (1) ◽  
pp. 414-420 ◽  
Author(s):  
E. Aikawa ◽  
A. Ueda ◽  
M. Watanabe ◽  
H. Takahashi ◽  
M. Imataki
1991 ◽  
Vol 11 (1) ◽  
pp. 68
Author(s):  
E. Aikawa ◽  
A. Ueda ◽  
M. Watanabe ◽  
H. Takahashi ◽  
M. Imataki

Author(s):  
Zhenxing Li ◽  
Jialing Wan ◽  
Pengfei Wang ◽  
Hanli Weng ◽  
Zhenhua Li

AbstractFault section location of a single-phase grounding fault is affected by the neutral grounding mode of the system, transition resistance, and the blind zone. A fault section locating method based on an amplitude feature and an intelligent distance algorithm is proposed to eliminate the influence of the above factors. By analyzing and comparing the amplitude characteristics of the zero-sequence current transient components at both ends of the healthy section and the faulty section, a distance algorithm with strong abnormal data immune capability is introduced in this paper. The matching degree of the amplitude characteristics at both ends of the feeder section are used as the criterion and by comparing with the set threshold, the faulty section is effectively determined. Finally, simulations using Matlab/Simulink and PSCAD/EMTDC show that the proposed section locating method can locate the faulty section accurately, and is not affected by grounding mode, grounding resistance, or the blind zone.


2021 ◽  
Vol 2095 (1) ◽  
pp. 012029
Author(s):  
Yicen Liu ◽  
Xiaojiang Liu ◽  
Songhai Fan ◽  
Xiaomin Ma ◽  
Sijing Deng

Abstract In view of the complex characteristics of nonlinearity and non-stableness of the zero-order current of each line after the single-phase ground fault of the distribution network, a distribution network fault selection method based on Sooty Tern Optimization Algorithm(STOA) and the combination of support vector machine is proposed. At first, the zero-sequence current before and after fault is obtained, then five kinds of IMFs including different components are obtained by ensemble empirical mode decomposition, and the energy entropy of the fault transient zero-sequence current is obtained by Hilbert transform, the results of training and testing are obtained by inputting the feature vector. The simulation results show that the accuracy of the proposed line selection model is 97.5%.


2012 ◽  
Vol 614-615 ◽  
pp. 846-849
Author(s):  
Shu Tian ◽  
Jin Peng He ◽  
Yu Zheng

When single phase-to-ground fault happened in power network with arc suppression coil grounded, capacitor current through fault point is compensated and reduced by installing arc suppression coil. Zero-sequence current’s amplitude and phase of fault lines and sound lines are so similar that it increases the difficulty of selecting the fault line. But the resistance component of zero sequence current has no relationship with the arc extinguishing coil compensation, absolute value of resistance component to the fault lines show the maximum, and zero sequence current’s polarity of fault lines is contrary to sound lines. In this paper, because of the characteristic of resistance component, a method is put forward based on zero sequence energy to the line selection in distribution network, it import auto-reclosing techniques into the line selection. The principle is verified by MATLAB simulator. It has high accuracy to select the fault line with this method.