Nondestructive determination of electromagnetic parameters of dielectric materials at X-band frequencies using a waveguide probe system

1997 ◽  
Vol 46 (5) ◽  
pp. 1084-1092 ◽  
Author(s):  
Chih-Wei Chang ◽  
Kun-Mu Chen ◽  
Jian Qian
2020 ◽  
Vol 400 ◽  
pp. 146-151
Author(s):  
Fadhéla Otmane ◽  
Zineb Hamlati ◽  
B. Rekioua ◽  
A. Maali ◽  
Mohammed Azzaz

Determination of the electromagnetic parameters is an important tool to evaluate the microwave-absorbing characteristic of a novel material. In this context, our research was carried out to investigate the electromagnetic parameters of nanocomposites samples obtained by inclusion of nanostructured Fe72Al23V5 powders in a resin matrix. Nanostructured Fe72Al23V5 powders were synthesized by high-energy mechanical alloying (MA) route and characterized using a scanning electron microscopy (SEM). The nanostructured Fe72Al23V5 powders were dispersed in an epoxy resin matrix. Nanocomposites bulk samples of rectangular section and given thickness were shaped for electromagnetic characterization in an X-band metallic rectangular waveguide. Electromagnetic characterization was performed in terms of measured Sij scattering parameters. Dielectric permittivity and magnetic permeability spectra were extracted over the microwave X-band via the transmission/reflection technique. Obtained results exhibit how the nature and size of the inclusions affect the electromagnetic parameters in the X-band frequencies.


Author(s):  
Vincent Cnockaert ◽  
Inge Bellemans ◽  
Tijl Crivits ◽  
Henk Vrielinck ◽  
Bart Blanpain ◽  
...  
Keyword(s):  

2020 ◽  
Vol 11 (1) ◽  
pp. 101
Author(s):  
Carlo Boursier Niutta

A new approach for the nondestructive determination of the elastic properties of composite laminates is presented. The approach represents an improvement of a recently published experimental methodology based on the Impulse Excitation Technique, which allows nondestructively assessing local elastic properties of composite laminates by isolating a region of interest through a proper clamping system. Different measures of the first resonant frequency are obtained by rotating the clamping system with respect to the material orientation. Here, in order to increase the robustness of the inverse problem, which determines the elastic properties from the measured resonant frequencies, information related to the modal shape is retained by considering the effect of an additional concentrated mass on the first resonant frequency. According to the modal shape and the position of the mass, different values of the first resonant frequency are obtained. Here, two positions of the additional mass, i.e., two values of the resonant frequency in addition to the unloaded frequency value, are considered for each material orientation. A Rayleigh–Ritz formulation based on higher order theory is adopted to compute the first resonant frequency of the clamped plate with concentrated mass. The elastic properties are finally determined through an optimization problem that minimizes the discrepancy on the frequency reference values. The proposed approach is validated on several materials taken from the literature. Finally, advantages and possible limitations are discussed.


2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Rüdiger Haas ◽  
Eskil Varenius ◽  
Saho Matsumoto ◽  
Matthias Schartner

AbstractWe present first results for the determination of UT1-UTC using the VLBI Global Observing System (VGOS). During December 2019 through February 2020, a series of 1 h long observing sessions were performed using the VGOS stations at Ishioka in Japan and the Onsala twin telescopes in Sweden. These VGOS-B sessions were observed simultaneously to standard legacy S/X-band Intensive sessions. The VGOS-B data were correlated, post-correlation processed, and analysed at the Onsala Space Observatory. The derived UT1-UTC results were compared to corresponding results from standard legacy S/X-band Intensive sessions (INT1/INT2), as well as to the final values of the International Earth Rotation and Reference Frame Service (IERS), provided in IERS Bulletin B. The VGOS-B series achieves 3–4 times lower formal uncertainties for the UT1-UTC results than standard legacy S/X-band INT series. The RMS agreement w.r.t. to IERS Bulletin B is slightly better for the VGOS-B results than for the simultaneously observed legacy S/X-band INT1 results, and the VGOS-B results have a small bias only with the smallest remaining standard deviation.


2016 ◽  
Vol 82 (5) ◽  
pp. 743-752 ◽  
Author(s):  
KUMIKO KUBO ◽  
YOSHIHIRO MATSUMOTO ◽  
KOICHI KUWAHARA ◽  
SYUUICHI OKABE ◽  
SHIGETO TANIYAMA ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document