scholarly journals Lower limit on the ultrahigh-energy proton-to-helium ratio from the measurements of the tail of the Xmax distribution

2018 ◽  
Vol 98 (10) ◽  
Author(s):  
Ivan S. Karpikov ◽  
Grigory I. Rubtsov ◽  
Yana V. Zhezher
1967 ◽  
Vol 23 (5) ◽  
pp. 1187-1193
Author(s):  
A. L. Mints ◽  
A. A. Vasil'ev ◽  
E. L. Burshtein

2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
J. P. Lansberg ◽  
R. Mikkelsen ◽  
U. I. Uggerhøj

We outline the opportunities to study the production of the Standard Model bosons,W±,Z0, andH0, at “low” energies at fixed-target experiments based on possible future ultrahigh-energy proton colliders, that is, the High-Energy LHC, the Super proton-proton Collider, and the Future Circular Collider hadron-hadron. These can be indeed made in conjunction with the proposed future colliders designed to reach up tos=100 TeV by using bent crystals to extract part of the halo of the beam which would then impinge on a fixed target. Without disturbing the collider operation, this technique allows for the extraction of a substantial amount of particles in addition to serving for a beam-cleaning purpose. With this method, high-luminosity fixed-target studies at centre-of-mass energies above theW±,Z0, andH0masses,s≃170–300 GeV, are possible. We also discuss the possibility offered by an internal gas target, which can also be used as luminosity monitor by studying the beam transverse shape.


1967 ◽  
Vol 31 ◽  
pp. 117-119
Author(s):  
F. D. Kahn ◽  
L. Woltjer

The efficiency of the transfer of energy from supernovae into interstellar cloud motions is investigated. A lower limit of about 0·002 is obtained, but values near 0·01 are more likely. Taking all uncertainties in the theory and observations into account, the energy per supernova, in the form of relativistic particles or high-velocity matter, needed to maintain the random motions in the interstellar gas is estimated as 1051·4±1ergs.


Author(s):  
Peng Wang ◽  
Zhongbin Pan ◽  
Weilin Wang ◽  
Jianxu Hu ◽  
Jinjun Liu ◽  
...  

High-performance electrostatic capacitors are in urgent demand owing to the rapidly development of advanced power electronic applications. However, polymer-based composite films with both high breakdown strength (Eb) and dielectric constant...


1998 ◽  
Vol 79 (01) ◽  
pp. 87-90 ◽  
Author(s):  
D. W. Jones ◽  
M. Winter ◽  
M. J. Gallimore

SummaryFactor XII (FXII) levels were determined in plasma samples from 29 normal donors, 10 patients with inherited FXII deficiency (all lupus anticoagulant [LA] negative) and 67 LA positive patients, using clotting (FXIIct), chromogenic substrate (FXIIcs) and immunochemical (FXIIag) assays. Excellent correlations were obtained in the three FXII assays with the LA negative samples and between the FXIIcs and FXIIag assays in the LA positive samples. Correlations between both the FXIIcs and FXIIag with FXIIct in the LA positive patients were poor. Of 67 LA positive samples studied, 25 (37.3%) showed lower values in the FXIIct assay; 13 (19.4%) of these patients were pseudo FXII deficient with values of FXII below the lower limit of normal.These results indicate that a diagnosis of FXII deficiency can be made inappropriately in the presence of phospholipid antibodies and that such a diagnosis should not be made by FXIIct assay alone.


Sign in / Sign up

Export Citation Format

Share Document