scholarly journals LAB–QA2GO: A free, easy-to-use toolbox for the quality assessment of magnetic resonance imaging data

2019 ◽  
Author(s):  
Christoph Vogelbacher ◽  
Miriam H. A. Bopp ◽  
Verena Schuster ◽  
Peer Herholz ◽  
Andreas Jansen ◽  
...  

AbstractImage characteristics of magnetic resonance imaging (MRI) data (e.g. signal-to-noise ratio, SNR) may change over the course of a study. To monitor these changes a quality assurance (QA) protocol is necessary. QA can be realized both by performing regular phantom measurements and by controlling the human MRI datasets (e.g. noise detection in structural or movement parameters in functional datasets). Several QA tools for the assessment of MRI data quality have been developed. Many of them are freely available. This allows in principle the flexible set-up of a QA protocol specifically adapted to the aims of one’s own study.However, setup and maintenance of these tools bind time, in particular since the installation and operation often require a fair amount of technical knowledge. In this article we present a light-weighted virtual machine, named LAB-QA2GO, which provides scripts for fully automated QA analyses of phantom and human datasets. This virtual machine is ready for analysis by starting it the first time. With minimal configuration in the guided web-interface the first analysis can start within 10 minutes, while adapting to local phantoms and needs is easily possible. The usability and scope of LAB–QA2GO is illustrated using a data set from the QA protocol of our lab. With LAB–QA2GO we hope to provide an easy-to-use toolbox that is able to calculate QA statistics without high effort.

2017 ◽  
Vol 11 (3) ◽  
Author(s):  
Felix Güttler ◽  
Andreas Heinrich ◽  
Peter Krauß ◽  
Jonathan Guntermann ◽  
Maximilian de Bucourt ◽  
...  

The purpose of this study was to evaluate the suitability of a novel radio-frequency identification (RFID)-based tracking system for intraoperative magnetic resonance imaging (MRI). A RFID tracking system was modified to fulfill MRI-compatibility and tested according to ASTM and NEMA. The influence of the RFID tracking system on MRI was analyzed in a phantom study using a half-Fourier acquisition single-shot turbospin echo (HASTE) and true fast imaging with steady-state precession sequence (TrueFISP) sequence. The RFID antenna was gradually moved closer to the isocenter of the MR scanner from 90 to 210 cm to investigate the influence of the distance. Furthermore, the RF was gradually changed between 865 and 869 MHz for a distance of 90 cm, 150 cm, and 210 cm to the isocenter of the magnet to investigate the influence of the frequency. The specific spatial resolution was measured with and without a permanent line of sight (LOS). After the modification of the reader, no significant change of the signal-to-noise ratio (SNR) could be observed with increasing distance of the RFID tracking system to the isocenter of the MR scanner. Also, different radio frequencies of the RFID tracking system did not influence the SNR of the MR-images significantly. The specific spatial resolution deviated on average by 8.97 ± 7.33 mm with LOS and 11.23 ± 12.03 mm without LOS from the reference system. The RFID tracking system had no relevant influence on the MR-image quality. RFID tracking solved the LOS problem. However, the spatial accuracy of the RFID tracking system has to be improved for medical usage.


2019 ◽  
Vol 142 (2) ◽  
Author(s):  
Thien-Khoi N. Phung ◽  
Christopher D. Waters ◽  
Jeffrey W. Holmes

Abstract Creating patient-specific models of the heart is a promising approach for predicting outcomes in response to congenital malformations, injury, or disease, as well as an important tool for developing and customizing therapies. However, integrating multimodal imaging data to construct patient-specific models is a nontrivial task. Here, we propose an approach that employs a prolate spheroidal coordinate system to interpolate information from multiple imaging datasets and map those data onto a single geometric model of the left ventricle (LV). We demonstrate the mapping of the location and transmural extent of postinfarction scar segmented from late gadolinium enhancement (LGE) magnetic resonance imaging (MRI), as well as mechanical activation calculated from displacement encoding with stimulated echoes (DENSE) MRI. As a supplement to this paper, we provide MATLAB and Python versions of the routines employed here for download from SimTK.


Author(s):  
Dang Khoa Nguyen ◽  
Manuela Temgoua Mbacfou ◽  
Dong Bach Nguyen ◽  
Maryse Lassonde

Purpose:To evaluate the prevalence of nonlesional focal epilepsy in an adult epilepsy clinic and its refractoriness to antiepileptic drug therapy.Background:Focal epilepsy is frequently, but not always, associated with structural epileptogenic lesions identifiable on magnetic resonance imaging (MRI).Methods:We analyzed the data from all patients evaluated at an adult epilepsy clinic from January 2002 to December 2011. Clinical and paraclinical findings were used to diagnose focal epilepsy. Magnetic resonance imaging were reviewed and classified as normal, with an epileptogenic lesion, or with a lesion of unclear epileptogenicity. Epileptogenic lesions were further categorized as tumours, vascular malformations, gliosis (including hippocampal atrophy/sclerosis), and malformations of cortical development. Our study group included patients with no lesions on MRI. Pharmacoresistance of patients with nonlesional focal epilepsy was assessed using the ILAE and Perucca's criterias.Results:Out of 1521 patients evaluated (mean age 44 years; range 14-93 years), 843 had focal epilepsy. Magnetic resonance imaging data, available for 806 (96%) subjects, showed epileptogenic lesions in 65%, no obvious epileptogenic lesions in 31% and lesions of unclear epileptogenicity in 4%. Magnetic resonance imaging-identified lesions included gliosis due to an acquired insult (52% including 17% of hippocampal atrophy or sclerosis), tumours (29%), vascular malformations (16%) and malformations of cortical development (10%). Fifty-two percent of nonlesional focal epileptic patients were drug-refractory.Conclusion:In a tertiary epilepsy clinic, close to a third of patients with focal epilepsy were found to be nonlesional, half of which were drug-resistant.


Author(s):  
Roger Luechinger ◽  
Torsten Sommer

Magnetic resonance imaging (MRI) is a safe diagnostic tool, with several hundred millions of safe diagnostic studies performed to date. However, there have been at least 15 published cases of patient deaths associated with MRI scanning: ten patients with implanted pacemakers, two patients with an insulin pump, one patient with a neurostimulator, one patient with an aneurysm clip, and one child killed by an oxygen tank. Additionally, hundreds of cases of severe burns or injuries due to ferromagnetic projectiles have also been reported. The main sources of all these risks are the electromagnetic fields of the MRI scanner used to create the images.


2020 ◽  
Vol 14 (4) ◽  
Author(s):  
Pankaj Kulkarni ◽  
Sakura Sikander ◽  
Pradipta Biswas ◽  
Sumit Laha ◽  
Heather Cornnell ◽  
...  

Abstract Significant research has been done in the past decade for the development of magnetic resonance imaging (MRI) guided needle guide (NG) systems for prostate intervention. Most of these systems have been restricted to application in the lab environment with lack of progress toward clinical application. Bulky and complex designs can be attributed to this practice. These systems also demand complex technical setup and usage procedures, which require extra technical personnel during the intervention in addition to specialized training for physicians. Moreover, “device-to-image” registration, essential for accurate and precise targeting, further complicates the overall process while increasing total time for intervention. In order to address these limitations, a simplified, MRI-guided, transperineal prostate biopsy NG system was designed and developed for rapid adoption into the clinical environment. The system consists of a NG device and a software toolkit. It does not require any special intraprocedural technical expertise or dedicated training. Also, to simplify and shorten total procedure time, the device uses the unique concept of “fixed coordinate device” eliminating the need for any device-to-image registration making it clinically friendly. To verify the NG design along with the registration free feature, image quality tests and agar phantom-based targeting experiments were performed under the guidance of 3T MRI scanner. The imaging tests resulted in a distortion of less than 1% in presence of the device and an average change of 1.3% in signal-to-noise ratio. For targeting experiments, maximum in-plane error distance of 3.8 mm with a mean of 2.2 mm and standard deviation of 0.8 mm was observed. The results show that an MRI-compatible simplified intervention device without the need of device-to-image registration is technically feasible.


1987 ◽  
Vol 42 (12) ◽  
pp. 1391-1395
Author(s):  
M. Braun ◽  
W. I. Jung ◽  
O. Lutz ◽  
R. Oeschey

Nuclear magnetic resonance imaging (MRI) of water and fat protons has been performed with a 1.5 T whole body imager. The highly selective excitation, necessary for the discrimination of the two proton species, has been achieved by different four and five pulse excitation schemes which had to be adapted to the needs of MRI and completed to imaging sequences. Their ability to produce well separated water and fat distribution images of test objects is demonstrated. The special features of the method such as signal-to-noise ratio, insensitivity to rf-field inhomogeneities, ease of implementation and data handling are discussed and compared to existing spectral separation techniques.


Author(s):  
Paulo A. W. G. Carvalho ◽  
Christopher J. Nycz ◽  
Katie Y. Gandomi ◽  
Gregory S. Fischer

Abstract Intra-operative medical imaging based on magnetic resonance imaging (MRI) coupled with robotic manipulation of surgical instruments enables precise feedback-driven procedures. Electrically powered nonferromagnetic motors based on piezoelectric elements have shown to be well suited for MRI robots. However, even avoiding ferrous materials, the high metal content on commercially available motors still cause distortions to the magnetic fields. We construct semicustom piezoelectric actuators wherein the quantity of conductive material is minimized and demonstrate that the distortion issues can be partly addressed through substituting several of these components for plastic equivalents, while maintaining motor functionality. Distortion was measured by assessing the root-mean-squared (RMS) change in position of 49 centroid points in a 12.5 mm square grid of a gelatin-filled phantom. The metal motor caused a distortion of up to 4.91 mm versus 0.55 mm for the plastic motor. An additional signal-to-noise-ratio (SNR) drop between motor off and motor spinning of approximately 20% was not statistically different for metal versus plastic (p = 0.36).


2020 ◽  
Author(s):  
Keerthi Sravan Ravi ◽  
Sairam Geethanath

AbstractAccess to Magnetic Resonance Imaging (MRI) across developing countries from being prohibitive to scarcely available. For example, eleven countries in Africa have no scanners. One critical limitation is the absence of skilled manpower required for MRI usage. Some of these challenges can be mitigated using autonomous MRI (AMRI) operation. In this work, we demonstrate AMRI to simplify MRI workflow by separating the required intelligence and user interaction from the acquisition hardware. AMRI consists of three components: user node, cloud and scanner. The user node voice interacts with the user and presents the image reconstructions at the end of the AMRI exam. The cloud generates pulse sequences and performs image reconstructions while the scanner acquires the raw data. An AMRI exam is a custom brain screen protocol comprising of one T1-, T2- and T2*-weighted exams. A neural network is trained to incorporate Intelligent Slice Planning (ISP) at the start of the AMRI exam. A Look Up Table was designed to perform intelligent protocolling by optimising for contrast value while satisfying signal to noise ratio and acquisition time constraints. Data were acquired from four healthy volunteers for three experiments with different acquisition time constraints to demonstrate standard and self-administered AMRI. The source code is available online. AMRI achieved an average SNR of 22.86 ± 0.89 dB across all experiments with similar contrast. Experiment #3 (33.66% shorter table time than experiment #1) yielded a SNR of 21.84 ± 6.36 dB compared to 23.48 ± 7.95 dB for experiment #1. AMRI can potentially enable multiple scenarios to facilitate rapid prototyping and research and streamline radiological workflow. We believe we have demonstrated the first Autonomous MRI of the brain.