scholarly journals First Osteosarcoma Reported from a New World Elapid Snake and Review of Reptilian Bony Tumors

2018 ◽  
Author(s):  
Alexander S. Hall ◽  
Justin L. Jacobs ◽  
Eric N. Smith

AbstractCancer chiefly occurs in vertebrates. Rare in amphibians, and perhaps common in reptiles, various neoplasms and malignant cancers have been reported with erratic frequency by museums, paleontologists, veterinarians, and pet hobbyists. Unsurprisingly, most herpetofaunal diversity has never been systematically surveyed for the presence of neoplasms owing to the extreme rarity or obscurity of many species. Museum collections can fill these gaps in knowledge, especially when researchers use non-destructive techniques. In this study, we used X-ray computed tomography to discover and characterize an osteosarcoma of the spine in a rare South American coralsnake, Micrurus ancoralis. Two spinal vertebrae were completely fused and adjacent vertebrae showed evidence of corruption. The fused vertebrae contained a hollow inner network thought to be vascular tissue. We also review previous reports of tumors in the Elapidae and all bony tumors in non-avian reptiles. The rarely reported technique of X-ray CT for tumor discovery could greatly improve our understanding of the species diversity and perhaps underlying causes of neoplasia.

Metals ◽  
2020 ◽  
Vol 10 (6) ◽  
pp. 726 ◽  
Author(s):  
Isabel Duarte ◽  
Thomas Fiedler ◽  
Lovre Krstulović-Opara ◽  
Matej Vesenjak

The paper presents a brief review of the main experimental and numerical techniques and standards to investigate and quantify the structural, mechanical, thermal, and acoustic properties of cellular metals. The potential of non-destructive techniques, such as X-ray computed tomography and infrared thermography are also presented.


2014 ◽  
Vol 27 ◽  
pp. 1460135
Author(s):  
CARMEN PAVEL ◽  
FLORIN CONSTANTIN ◽  
COSMIN IOAN SUCIU ◽  
ROXANA BUGOI

X-ray Computed Tomography (CT) is a powerful non-destructive technique that can yield interesting structural information not discernible through visual examination only. This paper presents the results of the CT scans of four objects belonging to the Romanian cultural heritage attributed to the Vinča, Cucuteni and Cruceni-Belegiš cultures. The study was performed with an X-ray tomographic device developed at the Department for Applied Nuclear Physics from Horia Hulubei National Institute for Nuclear Physics and Engineering in Măgurele, Romania. This apparatus was specially designed for archaeometric studies of low-Z artifacts: ceramic, wood, bone. The tomographic investigations revealed the internal configuration of the objects and provided information about the degree to which the previous manipulations affected the archaeological items. Based on the X-ray images resulting from the CT scans, hints about the techniques used in the manufacturing of the artifacts were obtained, as well as some indications useful for conservation/restoration purposes.


2009 ◽  
Vol 56 (3) ◽  
pp. 1448-1453 ◽  
Author(s):  
I. Lima ◽  
J. T. Assis ◽  
C. R. Apoloni ◽  
S. M. F. Mendonca de Souza ◽  
M. E. L. Duarte ◽  
...  

2019 ◽  
Vol 25 (2) ◽  
pp. 404-416 ◽  
Author(s):  
Tharmalingam Sivarupan ◽  
Mohamed El Mansori ◽  
Keith Daly ◽  
Mark Noel Mavrogordato ◽  
Fabrice Pierron

Purpose Micro-focus X-ray computed tomography (CT) can be used to quantitatively evaluate the packing density, pore connectivity and provide the basis for specimen derived simulations of gas permeability of sand mould. This non-destructive experiment or following simulations can be done on any section of any size sand mould just before casting to validate the required properties. This paper aims to describe the challenges of this method and use it to simulate the gas permeability of 3D printed sand moulds for a range of controlling parameters. The permeability simulations are compared against experimental results using traditional measurement techniques. It suggests that a minimum volume of only 700 × 700 × 700 µm3 is required to obtain, a reliable and most representative than the value obtained by the traditional measurement technique, the simulated permeability of a specimen. Design/methodology/approach X-ray tomography images were used to reconstruct 3D models to simulate them for gas permeability of the 3D printed sand mould specimens, and the results were compared with the experimental result of the same. Findings The influence of printing parameters, especially the re-coater speed, on the pore connectivity of the 3D printed sand mould and related permeability has been identified. Characterisation of these sand moulds using X-ray CT and its suitability, compared to the traditional means, are also studied. While density and 3PB strength are a measure of the quality of the moulds, the pore connectivity from the tomographic images precisely relates to the permeability. The main conclusions of the present study are provided below. A minimum required sample size of 700 × 700 × 700 µm3 is required to provide representative permeability results. This was obtained from sand specimens with an average sand grain size of 140 µm, using the tomographic volume images to define a 3D mesh to run permeability calculations. Z-direction permeability is always lower than that in the X-/Y-directions due to the lower values of X-(120/140 µm) and Y-(101.6 µm) resolutions of the furan droplets. The anisotropic permeability of the 3D printed sand mould is mainly due to, the only adjustable, X-directional resolution of the furan droplets; the Y-directional resolution is a fixed distance, 102.6 µm, between the printhead nozzles and the Z-directional one is usually, 280 µm, twice the size of an average sand grain.A non-destructive and most representative permeability value can be obtained, using the computer simulation, on the reconstructed 3D X-ray tomography images obtained on a specific location of a 3D printed sand mould. This saves time and effort on printing a separate specimen for the traditional test which may not be the most representative to the printed mould. Originality/value The experimental result is compared with the computer simulated results.


Sign in / Sign up

Export Citation Format

Share Document